GMP-compliant automated radiosynthesis of [18F] SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2 A (SV2A)

IF 4.4 Q1 CHEMISTRY, INORGANIC & NUCLEAR EJNMMI Radiopharmacy and Chemistry Pub Date : 2024-09-10 DOI:10.1186/s41181-024-00284-w
Lijuan Chen, Xiaochen Li, Yao Ge, Huiqiang Li, Ruili Li, Xiaosheng Song, Jianfei Liang, Weifeng Zhang, Xiaona Li, Xiaoqi Wang, Yunjuan Wang, Yaping Wu, Yan Bai, Meiyun Wang
{"title":"GMP-compliant automated radiosynthesis of [18F] SynVesT-1 for PET imaging of synaptic vesicle glycoprotein 2 A (SV2A)","authors":"Lijuan Chen,&nbsp;Xiaochen Li,&nbsp;Yao Ge,&nbsp;Huiqiang Li,&nbsp;Ruili Li,&nbsp;Xiaosheng Song,&nbsp;Jianfei Liang,&nbsp;Weifeng Zhang,&nbsp;Xiaona Li,&nbsp;Xiaoqi Wang,&nbsp;Yunjuan Wang,&nbsp;Yaping Wu,&nbsp;Yan Bai,&nbsp;Meiyun Wang","doi":"10.1186/s41181-024-00284-w","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>A novel positron emission tomography (PET) imaging tracer, [<sup>18</sup>F] SynVesT-1, targeting synaptic vesicle glycoprotein 2 (SV2A), has been developed to meet clinical demand. Utilizing the Trasis AllinOne-36 (AIO) module, we’ve automated synthesis to Good Manufacturing Practice (GMP) standards, ensuring sterile, pyrogen-free production. The fully GMP-compliant robust synthesis of [<sup>18</sup>F] SynVesT-1 boosting reliability and introducing a significant degree of simplicity and its comprehensive validation for routine human use.</p><h3>Results</h3><p>[<sup>18</sup>F] SynVesT-1 was synthesized by small modifications to the original [<sup>18</sup>F] SynVesT-1 synthesis protocol to better fit AIO module using an in-house designed cassette and sequence. With a relatively small precursor load of 5 mg, [<sup>18</sup>F] SynVesT-1 was obtained with consistently high radiochemical yields (RCY) of 20.6 ± 1.2% (the decay-corrected RCY, <i>n</i> = 3) at end of synthesis. Each of the final formulated batches demonstrated radiochemical purity (RCP) and enantiomeric purity surpassing 99%. The entire synthesis process was completed within a timeframe of 80 min (75 ± 3.1 min, <i>n</i> = 3), saves 11 min compared to reported GMP automated synthesis procedures. The in-human PET imaging of total body PET/CT and time-of-flight (TOF) PET/MR showed that [<sup>18</sup>F] SynVesT-1 is an excellent tracer for SV2A. It is advantageous for decentralized promotion and application in multi-center studies.</p><h3>Conclusion</h3><p>The use of AIO synthesizer maintains high production yields and increases reliability, reduces production time and allows rapid training of production staff. Besides, the as-prepared [<sup>18</sup>F] SynVesT-1 displays excellent in vivo binding properties in humans and holds great potential for the imaging and quantification of synaptic density in vivo.</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":"9 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-024-00284-w","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-024-00284-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

Background

A novel positron emission tomography (PET) imaging tracer, [18F] SynVesT-1, targeting synaptic vesicle glycoprotein 2 (SV2A), has been developed to meet clinical demand. Utilizing the Trasis AllinOne-36 (AIO) module, we’ve automated synthesis to Good Manufacturing Practice (GMP) standards, ensuring sterile, pyrogen-free production. The fully GMP-compliant robust synthesis of [18F] SynVesT-1 boosting reliability and introducing a significant degree of simplicity and its comprehensive validation for routine human use.

Results

[18F] SynVesT-1 was synthesized by small modifications to the original [18F] SynVesT-1 synthesis protocol to better fit AIO module using an in-house designed cassette and sequence. With a relatively small precursor load of 5 mg, [18F] SynVesT-1 was obtained with consistently high radiochemical yields (RCY) of 20.6 ± 1.2% (the decay-corrected RCY, n = 3) at end of synthesis. Each of the final formulated batches demonstrated radiochemical purity (RCP) and enantiomeric purity surpassing 99%. The entire synthesis process was completed within a timeframe of 80 min (75 ± 3.1 min, n = 3), saves 11 min compared to reported GMP automated synthesis procedures. The in-human PET imaging of total body PET/CT and time-of-flight (TOF) PET/MR showed that [18F] SynVesT-1 is an excellent tracer for SV2A. It is advantageous for decentralized promotion and application in multi-center studies.

Conclusion

The use of AIO synthesizer maintains high production yields and increases reliability, reduces production time and allows rapid training of production staff. Besides, the as-prepared [18F] SynVesT-1 displays excellent in vivo binding properties in humans and holds great potential for the imaging and quantification of synaptic density in vivo.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
符合 GMP 标准的[18F] SynVesT-1 自动放射合成技术,用于对突触小泡糖蛋白 2 A (SV2A) 进行 PET 成像
背景为满足临床需求,我们开发了一种新型正电子发射断层扫描(PET)成像示踪剂--[18F] SynVesT-1,其靶点是突触小泡糖蛋白 2 (SV2A)。利用 Trasis AllinOne-36 (AIO) 模块,我们按照药品生产质量管理规范 (GMP) 标准实现了自动化合成,确保了无菌、无热原生产。完全符合 GMP 标准的[18F] SynVesT-1 的稳健合成提高了可靠性,大大简化了操作,并对其在人类常规使用中的全面性进行了验证。前体载量相对较小,为 5 毫克,合成结束时,[18F] SynVesT-1 的放射化学收率(RCY)始终保持在 20.6 ± 1.2%(衰变校正 RCY,n = 3)的高水平。每个最终配制的批次的放射化学纯度(RCP)和对映体纯度都超过了 99%。整个合成过程在 80 分钟(75 ± 3.1 分钟,n = 3)内完成,比报告的 GMP 自动合成程序节省了 11 分钟。全身 PET/CT 和飞行时间 PET/MR 的人体 PET 成像显示,[18F] SynVesT-1 是 SV2A 的极佳示踪剂。结论使用 AIO 合成器可保持较高的产量,提高可靠性,缩短生产时间,并可快速培训生产人员。此外,制备的[18F] SynVesT-1 在人体中显示出优异的体内结合特性,在体内突触密度的成像和量化方面具有巨大潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
期刊最新文献
Automated radiofluorination of HER2 single domain antibody: the road towards the clinical translation of [18F]FB-HER2 sdAb Modified poly-L-lysine for use as a clearing agent in pretargeted radioimmunotherapy Exploring a tristhione scorpionate ligand as a suitable chelator for the theranostic pair antimony-119 and antimony-117 Design and development of nanoprobes radiolabelled with 99mTc for the diagnosis and monitoring of therapeutic interventions in oncology preclinical research Optimized method for fluorine-18 radiolabeling of Affibody molecules using RESCA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1