Learned Regularization for Quantitative Pulse-Echo Speed-of-Sound Imaging

Parisa Salemi YolgunluUniversity of Bern, Jules BlomUniversity of Twente, Naiara Korta MartiartuUniversity of Bern, Michael JaegerUniversity of Bern
{"title":"Learned Regularization for Quantitative Pulse-Echo Speed-of-Sound Imaging","authors":"Parisa Salemi YolgunluUniversity of Bern, Jules BlomUniversity of Twente, Naiara Korta MartiartuUniversity of Bern, Michael JaegerUniversity of Bern","doi":"arxiv-2408.11471","DOIUrl":null,"url":null,"abstract":"Computed ultrasound tomography in echo mode generates maps of tissue speed of\nsound (SoS) from the shift of echoes when detected under varying steering\nangles. It solves a linearized inverse problem that requires regularization to\ncomplement the echo shift data with a priori constraints. Spatial gradient\nregularization has been used to enforce smooth solutions, but SoS estimates\nwere found to be biased depending on tissue layer geometry. Here, we propose to\ntrain a linear operator to minimize SoS errors on average over a large number\nof random tissue models that sample the distribution of geometries and SoS\nvalues expected in vivo. In an extensive simulation study on liver imaging, we\ndemonstrate that biases are strongly reduced, with residual biases being the\nresult of a partial non-linearity in the actual physical problem. This approach\ncan either be applied directly to echo-shift data or to the SoS maps estimated\nwith gradient regularization, where the former shows slightly better\nperformance, but the latter is computationally more efficient. Experimental\nphantom results confirm the transferability of our results to real ultrasound\ndata.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2408.11471","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Computed ultrasound tomography in echo mode generates maps of tissue speed of sound (SoS) from the shift of echoes when detected under varying steering angles. It solves a linearized inverse problem that requires regularization to complement the echo shift data with a priori constraints. Spatial gradient regularization has been used to enforce smooth solutions, but SoS estimates were found to be biased depending on tissue layer geometry. Here, we propose to train a linear operator to minimize SoS errors on average over a large number of random tissue models that sample the distribution of geometries and SoS values expected in vivo. In an extensive simulation study on liver imaging, we demonstrate that biases are strongly reduced, with residual biases being the result of a partial non-linearity in the actual physical problem. This approach can either be applied directly to echo-shift data or to the SoS maps estimated with gradient regularization, where the former shows slightly better performance, but the latter is computationally more efficient. Experimental phantom results confirm the transferability of our results to real ultrasound data.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脉冲回波声速定量成像的学习正则化
在回波模式下,超声计算机断层扫描可根据在不同转向角下检测到的回波位移生成组织声速(SoS)图。它解决的是一个线性化的逆问题,需要通过正则化将回波位移数据与先验约束条件相结合。空间梯度正则化已被用于执行平滑解,但 SoS 估计值会因组织层的几何形状而产生偏差。在此,我们建议训练一个线性算子,以平均最小化大量随机组织模型的 SoS 误差,这些组织模型采样了体内预期的几何分布和 SoS 值。在对肝脏成像进行的大量模拟研究中,我们证明偏差已大大减少,残余偏差是实际物理问题中部分非线性的结果。这种方法既可以直接应用于回波平移数据,也可以应用于梯度正则化估算的 SoS 地图,前者的性能略好,但后者的计算效率更高。实验结果证实了我们的方法可以应用于真实的超声数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental Learning of a Hyperelastic Behavior with a Physics-Augmented Neural Network Modeling water radiolysis with Geant4-DNA: Impact of the temporal structure of the irradiation pulse under oxygen conditions Fast Spot Order Optimization to Increase Dose Rates in Scanned Particle Therapy FLASH Treatments The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy OpenDosimeter: Open Hardware Personal X-ray Dosimeter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1