Automatic retinal image analysis methods using colour fundus images for screening glaucomatous optic neuropathy

IF 2 Q2 OPHTHALMOLOGY BMJ Open Ophthalmology Pub Date : 2024-09-01 DOI:10.1136/bmjophth-2023-001594
Chuying Shi, Jack Lee, Di Shi, Gechun Wang, Fei Yuan, Benny Chung-Ying Zee
{"title":"Automatic retinal image analysis methods using colour fundus images for screening glaucomatous optic neuropathy","authors":"Chuying Shi, Jack Lee, Di Shi, Gechun Wang, Fei Yuan, Benny Chung-Ying Zee","doi":"10.1136/bmjophth-2023-001594","DOIUrl":null,"url":null,"abstract":"Objectives Train an automatic retinal image analysis (ARIA) method to screen glaucomatous optic neuropathy (GON) on non-mydriatic retinal images labelled with the additional results of optical coherence tomography (OCT) and assess different models for the GON classification. Methods All the images were obtained from the hospital for training and 10-fold cross-validation. Two methods were used to improve the classification performance: (1) using images labelled with the additional results of OCT as the reference standard and (2) generating models using retinal features from the entire images, the region of interest (ROI) of the optic disc, and the ROI of the macula, and the combination of all the features. Results Overall, we collected 1338 images with paired OCT scans. In 10-fold validation, ARIA achieved sensitivities of 92.2 %, 92.7% and 85.7%, specificities of 88.8%, 86.7% and 80.2% and accuracies of 90.6%, 89.9% and 83.1% using the retinal features from the entire images, the ROI of the optic disc and the ROI of the macula, respectively. We found the model combining all the features has the best classification performance and obtained a sensitivity of 92.5%, a specificity of 92.1% and an accuracy of 92.4%, which is significantly different from other models (p<0.001). Conclusion We used two methods to improve the classification performance and found the best model to detect glaucoma on colour fundus retinal images. It can become a cost-effective and relatively more accurate glaucoma screening tool than conventional methods. Data are available on reasonable request.","PeriodicalId":9286,"journal":{"name":"BMJ Open Ophthalmology","volume":"32 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjophth-2023-001594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives Train an automatic retinal image analysis (ARIA) method to screen glaucomatous optic neuropathy (GON) on non-mydriatic retinal images labelled with the additional results of optical coherence tomography (OCT) and assess different models for the GON classification. Methods All the images were obtained from the hospital for training and 10-fold cross-validation. Two methods were used to improve the classification performance: (1) using images labelled with the additional results of OCT as the reference standard and (2) generating models using retinal features from the entire images, the region of interest (ROI) of the optic disc, and the ROI of the macula, and the combination of all the features. Results Overall, we collected 1338 images with paired OCT scans. In 10-fold validation, ARIA achieved sensitivities of 92.2 %, 92.7% and 85.7%, specificities of 88.8%, 86.7% and 80.2% and accuracies of 90.6%, 89.9% and 83.1% using the retinal features from the entire images, the ROI of the optic disc and the ROI of the macula, respectively. We found the model combining all the features has the best classification performance and obtained a sensitivity of 92.5%, a specificity of 92.1% and an accuracy of 92.4%, which is significantly different from other models (p<0.001). Conclusion We used two methods to improve the classification performance and found the best model to detect glaucoma on colour fundus retinal images. It can become a cost-effective and relatively more accurate glaucoma screening tool than conventional methods. Data are available on reasonable request.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用彩色眼底图像筛查青光眼性视神经病变的自动视网膜图像分析方法
目的 在标有光学相干断层扫描(OCT)附加结果的非眼底视网膜图像上训练一种自动视网膜图像分析(ARIA)方法,以筛查青光眼性视神经病变(GON),并评估 GON 分类的不同模型。方法 所有图像均来自医院,用于训练和 10 倍交叉验证。为了提高分类性能,我们采用了两种方法:(1)使用 OCT 附加结果标记的图像作为参考标准;(2)使用整个图像、视盘感兴趣区(ROI)和黄斑感兴趣区的视网膜特征以及所有特征的组合生成模型。结果 我们共收集了 1338 张成对 OCT 扫描图像。在 10 倍验证中,ARIA 使用整个图像、视盘 ROI 和黄斑 ROI 的视网膜特征,灵敏度分别达到 92.2%、92.7% 和 85.7%,特异度分别达到 88.8%、86.7% 和 80.2%,准确度分别达到 90.6%、89.9% 和 83.1%。我们发现,结合所有特征的模型分类效果最好,灵敏度为 92.5%,特异度为 92.1%,准确率为 92.4%,与其他模型相比差异显著(p<0.001)。结论 我们用两种方法提高了分类性能,并找到了在彩色眼底视网膜图像上检测青光眼的最佳模型。与传统方法相比,它可以成为一种经济有效且相对更准确的青光眼筛查工具。如有合理要求,可提供相关数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Open Ophthalmology
BMJ Open Ophthalmology OPHTHALMOLOGY-
CiteScore
3.40
自引率
4.20%
发文量
104
审稿时长
20 weeks
期刊最新文献
Investigation of choroidal vascular alterations in eyes with myopia using ultrawidefield optical coherence tomography angiography. Recent advances in the application of artificial intelligence in age-related macular degeneration. Network-based hub biomarker discovery for glaucoma. Investigating the effects of simulated high altitude on colour discrimination. Total retinal thickness is an important factor in evaluating diabetic retinal neurodegeneration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1