Overcoming Limited Access to Virus Infection Rapid Testing: Development of a Lateral Flow Test for SARS-Cov-2 with Locally Available Resources

Biosensors Pub Date : 2024-08-27 DOI:10.3390/bios14090416
Estefanía S. Peri Ibáñez, Agostina Mazzeo, Carolina Silva, Maria Juliana Juncos, Guadalupe S. Costa Navarro, Horacio M. Pallarés, Virginia J. Wolos, Gabriel L. Fiszman, Silvia L. Mundo, Julio J. Caramelo, Marcelo J. Yanovsky, Matías Fingermann, Alejandro A. Castello, Andrea V. Gamarnik, Ana S. Peinetti, Daiana A. Capdevila
{"title":"Overcoming Limited Access to Virus Infection Rapid Testing: Development of a Lateral Flow Test for SARS-Cov-2 with Locally Available Resources","authors":"Estefanía S. Peri Ibáñez, Agostina Mazzeo, Carolina Silva, Maria Juliana Juncos, Guadalupe S. Costa Navarro, Horacio M. Pallarés, Virginia J. Wolos, Gabriel L. Fiszman, Silvia L. Mundo, Julio J. Caramelo, Marcelo J. Yanovsky, Matías Fingermann, Alejandro A. Castello, Andrea V. Gamarnik, Ana S. Peinetti, Daiana A. Capdevila","doi":"10.3390/bios14090416","DOIUrl":null,"url":null,"abstract":"The COVID-19 pandemic highlighted testing inequities in developing countries. Lack of lateral flow test (LFT) manufacturing capacity was a major COVID-19 response bottleneck in low- and middle-income regions. Here we report the development of an open-access LFT for SARS-CoV-2 detection comparable to commercial tests that requires only locally available supplies. The main critical resource is a locally developed horse polyclonal antibody (pAb) whose sensitivity and selectivity are greatly enhanced by affinity purification. We demonstrate that these Abs can perform similarly to commercial monoclonal antibodies (mAbs), as well as mAbs and other pAbs developed against the same antigen. We report a workflow for test optimization using nasopharyngeal swabs collected for RT-qPCR, spiked with the inactivated virus to determine analytical performance characteristics as the limit of detection, among others. Our final prototype showed a performance similar to available tests (sensitivity of 83.3% compared to RT-qPCR, and 90.9% compared to commercial antigen tests). Finally, we discuss the possibility and the challenges of utilizing affinity-purified pAbs as an alternative for the local development of antigen tests in an outbreak context and as a tool to address inequalities in access to rapid tests.","PeriodicalId":100185,"journal":{"name":"Biosensors","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3390/bios14090416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The COVID-19 pandemic highlighted testing inequities in developing countries. Lack of lateral flow test (LFT) manufacturing capacity was a major COVID-19 response bottleneck in low- and middle-income regions. Here we report the development of an open-access LFT for SARS-CoV-2 detection comparable to commercial tests that requires only locally available supplies. The main critical resource is a locally developed horse polyclonal antibody (pAb) whose sensitivity and selectivity are greatly enhanced by affinity purification. We demonstrate that these Abs can perform similarly to commercial monoclonal antibodies (mAbs), as well as mAbs and other pAbs developed against the same antigen. We report a workflow for test optimization using nasopharyngeal swabs collected for RT-qPCR, spiked with the inactivated virus to determine analytical performance characteristics as the limit of detection, among others. Our final prototype showed a performance similar to available tests (sensitivity of 83.3% compared to RT-qPCR, and 90.9% compared to commercial antigen tests). Finally, we discuss the possibility and the challenges of utilizing affinity-purified pAbs as an alternative for the local development of antigen tests in an outbreak context and as a tool to address inequalities in access to rapid tests.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
克服病毒感染快速检测的局限性:利用当地现有资源开发 SARS-Cov-2 侧流检测试剂盒
COVID-19 大流行凸显了发展中国家检测工作的不公平。缺乏侧流试验(LFT)生产能力是中低收入地区应对 COVID-19 的主要瓶颈。在此,我们报告了用于检测 SARS-CoV-2 的开放式侧流试验的开发情况,该试验与商业试验相当,只需当地供应。主要的关键资源是当地开发的马多克隆抗体(pAb),通过亲和纯化,这种抗体的灵敏度和选择性大大提高。我们证明,这些抗体的性能与商业单克隆抗体(mAbs)以及针对相同抗原开发的 mAbs 和其他 pAbs 相似。我们报告了使用鼻咽拭子进行 RT-qPCR 的测试优化工作流程,其中添加了灭活病毒,以确定检测限等分析性能特征。我们的最终原型显示出与现有测试类似的性能(与 RT-qPCR 相比灵敏度为 83.3%,与商业抗原测试相比灵敏度为 90.9%)。最后,我们讨论了利用亲和纯化 pAbs 作为疫情爆发情况下当地开发抗原检测的替代方法以及作为解决快速检测不平等问题的工具的可能性和挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection Ultrasensitive Electrochemical Biosensors Based on Allosteric Transcription Factors (aTFs) for Pb2+ Detection Salmonella Detection in Food Using a HEK-hTLR5 Reporter Cell-Based Sensor Paper-Based Microfluidic Device for Extracellular Lactate Detection Recent Electrochemical Advancements for Liquid-Biopsy Nucleic Acid Detection for Point-of-Care Prostate Cancer Diagnostics and Prognostics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1