A Novel Personalized Strategy for Hip Joint Flexion Assistance Based on Human Physiological State

Biosensors Pub Date : 2024-08-27 DOI:10.3390/bios14090418
Beixian Wu, Chunjie Chen, Sheng Wang, Hui Chen, Zhuo Wang, Yao Liu, Tingwei He, Jiale Zhang, Xinyu Wu
{"title":"A Novel Personalized Strategy for Hip Joint Flexion Assistance Based on Human Physiological State","authors":"Beixian Wu, Chunjie Chen, Sheng Wang, Hui Chen, Zhuo Wang, Yao Liu, Tingwei He, Jiale Zhang, Xinyu Wu","doi":"10.3390/bios14090418","DOIUrl":null,"url":null,"abstract":"Soft exosuits have emerged as potent assistive tools for walking support and rehabilitation training. However, most existing soft exosuit systems rely on preset assistance modes, which may not accurately align with individual physiological states and movement requirements, leading to variable user experiences and efficacy. While existing human-in-the-loop (HIL) research predominantly focuses on optimizing metabolic cost and torque difference parameters, there is a notable absence of real-time monitoring methods that closely reflect the human body’s physiological state and strategies that dynamically indicate walking efficiency. Motivated by this, we developed a novel personalized power-assist system. This system optimizes the power-assist output of the hip joint by monitoring the user’s physiological and motion signals in real time, including heart rate (HR), blood oxygen saturation (SpO2), and inertial measurement unit (IMU) data, to assist hip flexion based on feedback. The findings from a metabolic expenditure trial demonstrate that the innovative soft exosuit, which is based on a Physiological State Monitoring Control (PSMC) system, achieves a reduction of 7.81% in metabolic expenditure during treadmill walking at a speed of 3.5 km/h compared to walking without the assistance of the exosuit. Additionally, during continuous exercise with varying intensities, the metabolic consumption level is reduced by 5.1%, 5.8%, and 8.2% at speeds of 2, 4, and 6 km per hour, respectively. These results support the design of a novel hip flexion-assisting soft exosuit, demonstrating that applying different assistance forces in consideration of different physiological states is a reasonable approach to reducing metabolic consumption.","PeriodicalId":100185,"journal":{"name":"Biosensors","volume":"25 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.3390/bios14090418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Soft exosuits have emerged as potent assistive tools for walking support and rehabilitation training. However, most existing soft exosuit systems rely on preset assistance modes, which may not accurately align with individual physiological states and movement requirements, leading to variable user experiences and efficacy. While existing human-in-the-loop (HIL) research predominantly focuses on optimizing metabolic cost and torque difference parameters, there is a notable absence of real-time monitoring methods that closely reflect the human body’s physiological state and strategies that dynamically indicate walking efficiency. Motivated by this, we developed a novel personalized power-assist system. This system optimizes the power-assist output of the hip joint by monitoring the user’s physiological and motion signals in real time, including heart rate (HR), blood oxygen saturation (SpO2), and inertial measurement unit (IMU) data, to assist hip flexion based on feedback. The findings from a metabolic expenditure trial demonstrate that the innovative soft exosuit, which is based on a Physiological State Monitoring Control (PSMC) system, achieves a reduction of 7.81% in metabolic expenditure during treadmill walking at a speed of 3.5 km/h compared to walking without the assistance of the exosuit. Additionally, during continuous exercise with varying intensities, the metabolic consumption level is reduced by 5.1%, 5.8%, and 8.2% at speeds of 2, 4, and 6 km per hour, respectively. These results support the design of a novel hip flexion-assisting soft exosuit, demonstrating that applying different assistance forces in consideration of different physiological states is a reasonable approach to reducing metabolic consumption.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于人体生理状态的新型髋关节屈伸辅助个性化策略
软质外衣已成为行走支持和康复训练的有力辅助工具。然而,大多数现有的软质外衣系统都依赖于预设的辅助模式,这些模式可能无法准确符合个人的生理状态和运动要求,从而导致用户体验和功效各不相同。虽然现有的人体在环(HIL)研究主要集中在优化代谢成本和扭矩差参数上,但密切反映人体生理状态的实时监测方法和动态显示行走效率的策略却明显缺乏。受此启发,我们开发了一种新型个性化动力辅助系统。该系统通过实时监测用户的生理和运动信号(包括心率(HR)、血氧饱和度(SpO2)和惯性测量单元(IMU)数据)来优化髋关节的动力辅助输出,并根据反馈来辅助髋关节屈曲。代谢消耗试验结果表明,基于生理状态监测控制(PSMC)系统的创新型软外穿衣在跑步机上以 3.5 公里/小时的速度行走时,与没有外穿衣辅助的行走相比,代谢消耗减少了 7.81%。此外,在不同强度的连续运动中,以每小时 2 公里、4 公里和 6 公里的速度行走时,代谢消耗水平分别降低了 5.1%、5.8% 和 8.2%。这些结果支持新型髋关节屈曲辅助软外装的设计,证明根据不同的生理状态施加不同的辅助力是减少代谢消耗的合理方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection Ultrasensitive Electrochemical Biosensors Based on Allosteric Transcription Factors (aTFs) for Pb2+ Detection Salmonella Detection in Food Using a HEK-hTLR5 Reporter Cell-Based Sensor Paper-Based Microfluidic Device for Extracellular Lactate Detection Recent Electrochemical Advancements for Liquid-Biopsy Nucleic Acid Detection for Point-of-Care Prostate Cancer Diagnostics and Prognostics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1