Reliability of Uroflowmetry Pattern Interpretation in Adult Women.

IF 1.8 3区 医学 Q3 UROLOGY & NEPHROLOGY Neurourology and Urodynamics Pub Date : 2024-09-12 DOI:10.1002/nau.25584
Leslie M Rickey,Elizabeth R Mueller,Diane K Newman,Alayne D Markland,Chloe Falke,Kyle Rudser,Ariana L Smith,Margaret G Mueller,Jerry L Lowder,Emily S Lukacz,
{"title":"Reliability of Uroflowmetry Pattern Interpretation in Adult Women.","authors":"Leslie M Rickey,Elizabeth R Mueller,Diane K Newman,Alayne D Markland,Chloe Falke,Kyle Rudser,Ariana L Smith,Margaret G Mueller,Jerry L Lowder,Emily S Lukacz,","doi":"10.1002/nau.25584","DOIUrl":null,"url":null,"abstract":"INTRODUCTION\r\nUroflowmetry is often used to assess lower urinary tract symptoms (LUTS). Criteria for characterization of flow patterns are not well established, and subjective interpretation is the most common approach for flow curve classification. We assessed the reliability of uroflowmetry curve interpretation in adult women.\r\n\r\nMATERIALS AND METHODS\r\nUroflowmetry studies were obtained in 296 women who participated in an observational cohort study. Four investigators with expertise in female LUTS and urodynamics reviewed and categorized each tracing for interrater reliability. A random subset of 50 tracings was re-reviewed by each investigator for intrarater reliability. The uroflowmetry tracings were rated using categories of continuous, continuous fluctuating, interrupted, and prolonged. Other parameters included flow rate, voided volume, time to maximum flow, and voiding time. Agreement between raters is summarized with kappa (k) statistics and percentage where at least three raters agreed.\r\n\r\nRESULTS\r\nThe mean age of participants was 44.8 ± 18.3 years. Participant age categories were 18-24 years: 20%; 25-34 years: 17%; 35-64 years: 42%; 65+ years: 18%. Nine percent described their race as Asian, 31% Black, 62% White, and 89% were of non-Hispanic ethnicity. The interrater reliability was highest for the continuous flow category (k = 0.65), 0.47 for prolonged, 0.41 for continuous fluctuating, and 0.39 for interrupted flow curves. Agreement among at least three raters occurred in 74.3% of uroflow curves (69% for continuous, 33% for continuous fluctuating, 23% for interrupted, and 25% for prolonged). For intrarater reliability, the mean k was 0.72 with a range of 0.57-0.85.\r\n\r\nCONCLUSIONS\r\nCurrently accepted uroflowmetry pattern categories have fair to moderate interrater reliability, which is lower for flow curves that do not meet \"continuous\" criteria. Given the subjective nature of interpreting uroflowmetry data, more consistent and clear parameters may enhance reliability for use in research and as a screening tool for LUTS and voiding dysfunction.\r\n\r\nTRIAL REGISTRATION\r\nParent trial: Validation of Bladder Health Instrument for Evaluation in Women (VIEW); ClinicalTrials.gov ID: NCT04016298.","PeriodicalId":19200,"journal":{"name":"Neurourology and Urodynamics","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurourology and Urodynamics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nau.25584","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

INTRODUCTION Uroflowmetry is often used to assess lower urinary tract symptoms (LUTS). Criteria for characterization of flow patterns are not well established, and subjective interpretation is the most common approach for flow curve classification. We assessed the reliability of uroflowmetry curve interpretation in adult women. MATERIALS AND METHODS Uroflowmetry studies were obtained in 296 women who participated in an observational cohort study. Four investigators with expertise in female LUTS and urodynamics reviewed and categorized each tracing for interrater reliability. A random subset of 50 tracings was re-reviewed by each investigator for intrarater reliability. The uroflowmetry tracings were rated using categories of continuous, continuous fluctuating, interrupted, and prolonged. Other parameters included flow rate, voided volume, time to maximum flow, and voiding time. Agreement between raters is summarized with kappa (k) statistics and percentage where at least three raters agreed. RESULTS The mean age of participants was 44.8 ± 18.3 years. Participant age categories were 18-24 years: 20%; 25-34 years: 17%; 35-64 years: 42%; 65+ years: 18%. Nine percent described their race as Asian, 31% Black, 62% White, and 89% were of non-Hispanic ethnicity. The interrater reliability was highest for the continuous flow category (k = 0.65), 0.47 for prolonged, 0.41 for continuous fluctuating, and 0.39 for interrupted flow curves. Agreement among at least three raters occurred in 74.3% of uroflow curves (69% for continuous, 33% for continuous fluctuating, 23% for interrupted, and 25% for prolonged). For intrarater reliability, the mean k was 0.72 with a range of 0.57-0.85. CONCLUSIONS Currently accepted uroflowmetry pattern categories have fair to moderate interrater reliability, which is lower for flow curves that do not meet "continuous" criteria. Given the subjective nature of interpreting uroflowmetry data, more consistent and clear parameters may enhance reliability for use in research and as a screening tool for LUTS and voiding dysfunction. TRIAL REGISTRATION Parent trial: Validation of Bladder Health Instrument for Evaluation in Women (VIEW); ClinicalTrials.gov ID: NCT04016298.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
成年女性尿流率测量模式判读的可靠性
导言尿流测定法常用于评估下尿路症状(LUTS)。尿流模式的特征描述标准尚不完善,主观解释是尿流曲线分类最常用的方法。我们评估了成年女性尿流率测量曲线判读的可靠性。材料和方法尿流率测量研究的对象是参与观察性队列研究的 296 名女性。四名在女性尿失禁和尿动力学方面具有专长的研究人员对每条描记曲线进行了审查和分类,以确保研究人员之间的可靠性。每名研究人员随机抽取 50 个描记样本进行复查,以确保描记样本的内部可靠性。尿流率测量描记分为连续、连续波动、中断和延长四类。其他参数包括流速、排尿量、达到最大流量的时间和排尿时间。评分者之间的一致性用卡帕(kappa)统计和至少三名评分者一致的百分比进行总结。参与者的年龄分布为:18-24 岁:20%;25-34 岁:17%;35-64 岁:17%:17%;35-64 岁42%;65 岁以上:18%:18%.9%的人自称种族为亚洲人,31%为黑人,62%为白人,89%为非西班牙裔。连续血流类别的评分者间可靠性最高(k = 0.65),延长血流类别的评分者间可靠性为 0.47,连续波动血流类别的评分者间可靠性为 0.41,间断血流曲线类别的评分者间可靠性为 0.39。74.3%的尿流曲线(69%为连续性,33%为连续波动性,23%为间断性,25%为延长性)至少有三名评分者的评分结果一致。结论目前公认的尿流测量模式分类具有一般到中等程度的评分者间可靠性,而不符合 "连续 "标准的尿流曲线的评分者间可靠性则较低。鉴于尿流率测量数据解释的主观性,更一致、更明确的参数可提高可靠性,用于研究以及作为 LUTS 和排尿功能障碍的筛查工具:妇女膀胱健康评估工具验证(VIEW);ClinicalTrials.gov ID:NCT04016298。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Neurourology and Urodynamics
Neurourology and Urodynamics 医学-泌尿学与肾脏学
CiteScore
4.30
自引率
10.00%
发文量
231
审稿时长
4-8 weeks
期刊介绍: Neurourology and Urodynamics welcomes original scientific contributions from all parts of the world on topics related to urinary tract function, urinary and fecal continence and pelvic floor function.
期刊最新文献
Impact of Antibiotic Choice at the Time of Sacral Neuromodulation Implantation on Rates of Surgical Site Infection. Comparison of Surgical Outcomes of Autologous Mid-Urethral Fascia Slings and Retropubic Mid-Urethral Slings for Women Undergoing a Primary Surgery for Stress Urinary Incontinence: A Systematic Review and Meta-Analysis. Development and Testing of the Spinal Cord Injury Bladder and Bowel Control Questionnaire (SCI-BBC-Q). Growing Up With Neurogenic Bladder: Navigating the Challenges and Controversies in Pediatric to Adult Transition and Lifelong Care: A Report From the Neurogenic Bladder Research Group (NBRG). Preventive Effects of Gonadotropin-Releasing Hormone Treatment on Urinary Bladder and Kidney Damage in Spinal Cord Injured Rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1