A flexible electrochemical sensor based on Fe-doped polydopamine derived carbon for simultaneous detection of dopamine and uric acid†

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-09-03 DOI:10.1039/D4AY00980K
Xinyu Wang, Wenbin Wang, Meng Gao, Min Fu, Linzheng Ma and Wei Chen
{"title":"A flexible electrochemical sensor based on Fe-doped polydopamine derived carbon for simultaneous detection of dopamine and uric acid†","authors":"Xinyu Wang, Wenbin Wang, Meng Gao, Min Fu, Linzheng Ma and Wei Chen","doi":"10.1039/D4AY00980K","DOIUrl":null,"url":null,"abstract":"<p >A free-standing electrode based on carbon cloth-supported Fe-doped polydopamine-derived carbon (Fe/PDA-C/CC) was developed for the simultaneous detection of dopamine (DA) and uric acid (UA). First, dopamine was self-polymerized on the surface of the carbon cloth to obtain polydopamine coatings. Subsequently, Fe<small><sup>3+</sup></small> was introduced through the formation of a coordinate bond with the hydroxyl functional group in the polydopamine layer. After calcination, a flexible and free-standing electrode was obtained. The sensing performance and mechanism of the Fe/PDA-C/CC sensor was investigated and is discussed in detail herein. Experimental results demonstrated that Fe/PDA-C/CC could simultaneously detect DA and UA with a wide detection range of 0.5–300 μM and 0.5–400 μM with low detection limits of 0.041 μM and 0.012 μM, respectively. Meanwhile, Fe/PDA-C/CC possessed excellent anti-interference performance, repeatability, stability, and accuracy in real samples. Overall, this study provides a facile and effective approach for simultaneous detection of UA and DA.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 41","pages":" 6974-6987"},"PeriodicalIF":2.6000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00980k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A free-standing electrode based on carbon cloth-supported Fe-doped polydopamine-derived carbon (Fe/PDA-C/CC) was developed for the simultaneous detection of dopamine (DA) and uric acid (UA). First, dopamine was self-polymerized on the surface of the carbon cloth to obtain polydopamine coatings. Subsequently, Fe3+ was introduced through the formation of a coordinate bond with the hydroxyl functional group in the polydopamine layer. After calcination, a flexible and free-standing electrode was obtained. The sensing performance and mechanism of the Fe/PDA-C/CC sensor was investigated and is discussed in detail herein. Experimental results demonstrated that Fe/PDA-C/CC could simultaneously detect DA and UA with a wide detection range of 0.5–300 μM and 0.5–400 μM with low detection limits of 0.041 μM and 0.012 μM, respectively. Meanwhile, Fe/PDA-C/CC possessed excellent anti-interference performance, repeatability, stability, and accuracy in real samples. Overall, this study provides a facile and effective approach for simultaneous detection of UA and DA.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于掺杂铁的多巴胺衍生碳的柔性电化学传感器,用于同时检测多巴胺和尿酸
基于碳布支撑的掺杂铁的聚多巴胺衍生碳(Fe/PDA-C/CC)开发了一种独立电极,用于同时检测多巴胺(DA)和尿酸(UA)。首先,在碳布表面自聚多巴胺,得到多巴胺涂层。然后,通过与多巴胺涂层中的羟基官能团形成配位键引入 Fe3+。经过煅烧后,就得到了柔性独立电极。实验详细研究并讨论了 Fe/PDA-C/CC 传感器的传感性能和机理。实验结果表明,Fe/PDA-C/CC 可同时检测 DA 和 UA,检测范围分别为 0.5-300 μM 和 0.5-400 μM,检出限分别为 0.041 μM 和 0.012 μM。同时,Fe/PDA-C/CC 在实际样品中具有良好的抗干扰性、重复性、稳定性和准确性。总之,该研究为同时检测 UA 和 DA 提供了一种简便有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
Back cover Analysis of diazepam residues in aquatic products based on magnetic molecularly imprinted polymers. Single-enzyme-driven cascade amplification integrating target recycling and a DNA walker for highly sensitive nucleic acid detection. Capillary electrophoresis-contactless conductivity detection for routine screening of PDE-5 inhibitor adulterants in sexual-enhancement supplements. DNA-mediated synergistic proximity ligation for ultrasensitive electrochemiluminescence detection of microcystin-LR.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1