Experimental study on fatigue damage mitigation in welded beam-to-column connections with passive vibration control

IF 2.1 4区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Advances in Structural Engineering Pub Date : 2024-09-09 DOI:10.1177/13694332241281531
Fan Yang, Zhao Fang, Jianshao Zhang, Aiqun Li
{"title":"Experimental study on fatigue damage mitigation in welded beam-to-column connections with passive vibration control","authors":"Fan Yang, Zhao Fang, Jianshao Zhang, Aiqun Li","doi":"10.1177/13694332241281531","DOIUrl":null,"url":null,"abstract":"To investigate the effectiveness of a viscous fluid damper (VFD) in mitigating fatigue damage in welded beam-to-column connections, six specimens were manufactured with the full penetration groove weld process. These specimens were divided into three groups: S1, S2, and S3, each containing two specimens. One specimen in each group was equipped with VFD, while the other was not. All specimens underwent the same elastic cyclic loading stage, but a different plastic cyclic loading stage for each group. The study results indicate that the presence of VFD can significantly enhance the load-bearing capacity of the welded beam-to-column connection by 10%–15% when subjected to the same displacement amplitude at the beam end. The primary cause of failure in the welded beam-to-column connection is the fatigue damage of the weld toe on the beam flange, which requires more attention during the welding process. Additionally, the VFD can effectively reduce stress concentration at the weld seam area, leading to a maximum of 50% decrease in the maximum stress near the weld toe of the beam flange center, as observed in our study.","PeriodicalId":50849,"journal":{"name":"Advances in Structural Engineering","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Structural Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/13694332241281531","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

To investigate the effectiveness of a viscous fluid damper (VFD) in mitigating fatigue damage in welded beam-to-column connections, six specimens were manufactured with the full penetration groove weld process. These specimens were divided into three groups: S1, S2, and S3, each containing two specimens. One specimen in each group was equipped with VFD, while the other was not. All specimens underwent the same elastic cyclic loading stage, but a different plastic cyclic loading stage for each group. The study results indicate that the presence of VFD can significantly enhance the load-bearing capacity of the welded beam-to-column connection by 10%–15% when subjected to the same displacement amplitude at the beam end. The primary cause of failure in the welded beam-to-column connection is the fatigue damage of the weld toe on the beam flange, which requires more attention during the welding process. Additionally, the VFD can effectively reduce stress concentration at the weld seam area, leading to a maximum of 50% decrease in the maximum stress near the weld toe of the beam flange center, as observed in our study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用被动振动控制减轻梁柱焊接连接疲劳损伤的实验研究
为了研究粘性流体阻尼器(VFD)在减轻梁柱焊接连接疲劳损伤方面的效果,我们采用全熔透沟槽焊接工艺制作了六个试样。这些试样被分为三组:S1、S2 和 S3,每组包含两个试样。每组中有一个试样安装了变频驱动装置,另一个试样则没有。所有试样都经历了相同的弹性循环加载阶段,但每组都经历了不同的塑性循环加载阶段。研究结果表明,在梁端承受相同的位移振幅时,装有变频驱动装置的焊接梁柱连接的承载能力可显著提高 10%-15%。梁柱焊接连接失效的主要原因是梁翼缘焊趾的疲劳破坏,这需要在焊接过程中多加注意。此外,VFD 还能有效减少焊缝区域的应力集中,从而使梁翼缘板中心焊趾附近的最大应力最多降低 50%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Structural Engineering
Advances in Structural Engineering 工程技术-工程:土木
CiteScore
5.00
自引率
11.50%
发文量
230
审稿时长
2.3 months
期刊介绍: Advances in Structural Engineering was established in 1997 and has become one of the major peer-reviewed journals in the field of structural engineering. To better fulfil the mission of the journal, we have recently decided to launch two new features for the journal: (a) invited review papers providing an in-depth exposition of a topic of significant current interest; (b) short papers reporting truly new technologies in structural engineering.
期刊最新文献
Multi-experimental seismic analysis of low-rise thin reinforced concrete wall building with unconnected elastomeric isolators using real-time hybrid simulations Prediction and optimization framework of shear strength of reinforced concrete flanged shear wall based on machine learning and non-dominated sorting genetic algorithm-II Deep learning-based minute-scale digital prediction model for temperature induced deflection of a multi-tower double-layer steel truss bridge Experimental investigation on shear behavior of double-row perforated GFRP rib connectors in FRP-concrete hybrid beams Seismic response prediction method of train-bridge coupled system based on convolutional neural network-bidirectional long short-term memory-attention modeling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1