{"title":"Experimental and numerical study on mechanical properties of PC shear wall bolted connection joints","authors":"Yindong Gong, Yunpeng Chu, Yanhui Liu, Zhipeng Zhai","doi":"10.1177/13694332241281542","DOIUrl":null,"url":null,"abstract":"Steel-bolt connection joint with embedded steel is increasingly utilized for prefabricated concrete (PC) shear walls and plays an indispensable role in the shear force transmission process. To enhance the mechanical performance of the connection joint in PC walls, a new pre-embedded steel bolt connection is proposed in this paper. The new connection can quickly connect prefabricated shear walls, with a simple construction process and short construction period. The present study respectively designed and fabricated four specimens with different connection configurations to conduct shear performance tests on the steel connectors and hysteresis performance tests on the connection joint. A numerical model for the joint was then established based on the shear test data of the steel connectors, to further analyze the mechanical performance of the proposed connection joint. The results indicate that depending on the different steel connection configurations, shear failure modes can be categorized into bolt shear failure and embedded steel pullout failure. The shear studs have minimal impact on the shear performance of the steel connectors. The flanges on both sides of the joint effectively enhance the hysteresis performance of the connection joint. Among the tested specimens, the one with a steel configuration at the connection joint featuring ribbed channel steel exhibits superior hysteresis performance, with higher load-bearing capacity, gradual stiffness degradation, and excellent energy dissipation capability. It is recommended to use these connection details for embedded steel connections at the joint during the design.","PeriodicalId":50849,"journal":{"name":"Advances in Structural Engineering","volume":"168 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Structural Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/13694332241281542","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Steel-bolt connection joint with embedded steel is increasingly utilized for prefabricated concrete (PC) shear walls and plays an indispensable role in the shear force transmission process. To enhance the mechanical performance of the connection joint in PC walls, a new pre-embedded steel bolt connection is proposed in this paper. The new connection can quickly connect prefabricated shear walls, with a simple construction process and short construction period. The present study respectively designed and fabricated four specimens with different connection configurations to conduct shear performance tests on the steel connectors and hysteresis performance tests on the connection joint. A numerical model for the joint was then established based on the shear test data of the steel connectors, to further analyze the mechanical performance of the proposed connection joint. The results indicate that depending on the different steel connection configurations, shear failure modes can be categorized into bolt shear failure and embedded steel pullout failure. The shear studs have minimal impact on the shear performance of the steel connectors. The flanges on both sides of the joint effectively enhance the hysteresis performance of the connection joint. Among the tested specimens, the one with a steel configuration at the connection joint featuring ribbed channel steel exhibits superior hysteresis performance, with higher load-bearing capacity, gradual stiffness degradation, and excellent energy dissipation capability. It is recommended to use these connection details for embedded steel connections at the joint during the design.
预埋钢筋的钢螺栓连接接头越来越多地用于预制混凝土(PC)剪力墙,在剪力传递过程中发挥着不可或缺的作用。为了提高 PC 墙连接接头的机械性能,本文提出了一种新型预埋钢螺栓连接。这种新型连接方式可快速连接预制剪力墙,施工工艺简单,施工周期短。本研究分别设计并制作了四个不同连接构造的试件,对钢连接件进行了剪切性能测试,并对连接接头进行了滞后性能测试。然后,根据钢连接件的剪切试验数据建立了连接接头的数值模型,进一步分析了拟建连接接头的力学性能。结果表明,根据不同的钢连接结构,剪切失效模式可分为螺栓剪切失效和嵌入钢拉拔失效。剪切螺栓对钢连接件的剪切性能影响很小。连接件两侧的法兰可有效提高连接件的滞后性能。在测试的试样中,连接接头处钢结构为带肋槽钢的试样具有更优越的滞后性能、更高的承载能力、渐进的刚度衰减和出色的消能能力。建议在设计中使用这些连接细节来处理连接处的嵌入式钢连接。
期刊介绍:
Advances in Structural Engineering was established in 1997 and has become one of the major peer-reviewed journals in the field of structural engineering. To better fulfil the mission of the journal, we have recently decided to launch two new features for the journal: (a) invited review papers providing an in-depth exposition of a topic of significant current interest; (b) short papers reporting truly new technologies in structural engineering.