Approaching the Lower Temporal Limit of Laser-Produced Plasma Sources for Table-Top Soft X-ray NEXAFS Measurements

Danika Nimlos, Alejandro Arellano, Scott Kevin Cushing
{"title":"Approaching the Lower Temporal Limit of Laser-Produced Plasma Sources for Table-Top Soft X-ray NEXAFS Measurements","authors":"Danika Nimlos, Alejandro Arellano, Scott Kevin Cushing","doi":"arxiv-2409.02280","DOIUrl":null,"url":null,"abstract":"The increasing popularity of time-resolved X-ray absorption measurements for\nunderstanding dynamics in molecular and material systems has led to many\nadvances in table-top sources for pulsed X-rays. We report on a table top\nlaser-produced plasma (LPP) source that can perform soft X-ray (SXR), near edge\nX-ray absorption fine structure (NEXAFS) measurements using a laser source with\n23 ps pulse duration. The spectrometer's key specifications, such as\nbrilliance, resolution, and stability, are characterized against the more\ncommonly used longer-pulse-duration LPP sources. The 23 ps laser produced\napproximately an order of magnitude weaker SXR flux than the 8 ns laser for a\nhigher power density due to the smaller total energy absorbed by the plasma.\nThe increased repetition rate and an implemented self-referencing scheme still\nallowed for high-resolution, synchrotron-like NEXAFS measurements of Si3N4 and\nTiO2 thin films with 2.5 minute acquisition times. It was observed that\ndegradation of the gas jet nozzle led to long-term instability of the source,\nwhich can be remediated using alternative nozzle designs. This work\ndemonstrates the feasibility of achieving higher temporal resolution in future\ntime-resolved X-ray absorption measurements using table-top laser-produced\nplasma sources","PeriodicalId":501274,"journal":{"name":"arXiv - PHYS - Plasma Physics","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - PHYS - Plasma Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2409.02280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing popularity of time-resolved X-ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table-top sources for pulsed X-rays. We report on a table top laser-produced plasma (LPP) source that can perform soft X-ray (SXR), near edge X-ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer-pulse-duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate and an implemented self-referencing scheme still allowed for high-resolution, synchrotron-like NEXAFS measurements of Si3N4 and TiO2 thin films with 2.5 minute acquisition times. It was observed that degradation of the gas jet nozzle led to long-term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time-resolved X-ray absorption measurements using table-top laser-produced plasma sources
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
接近用于桌面软 X 射线 NEXAFS 测量的激光产生等离子体源的时间下限
为了解分子和材料系统的动力学而进行的时间分辨 X 射线吸收测量越来越受欢迎,这促使台式脉冲 X 射线源取得了许多进展。我们报告了一种台式激光产生的等离子体(LPP)源,它可以使用 23 ps 脉冲持续时间的激光源进行软 X 射线(SXR)、近边缘 X 射线吸收精细结构(NEXAFS)测量。该光谱仪的主要技术指标,如亮度、分辨率和稳定性等,都是根据更常用的长脉冲持续时间 LPP 源来确定的。由于等离子体吸收的总能量较小,在较高功率密度下,23 ps 激光产生的 SXR 流量比 8 ns 激光产生的 SXR 流量弱大约一个数量级。据观察,气体喷射喷嘴的退化导致了光源的长期不稳定性,这可以通过使用替代喷嘴设计来解决。这项工作证明了在未来使用台式激光等离子体源进行时间分辨 X 射线吸收测量时实现更高的时间分辨率的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Oscillation damper for misaligned witness in plasma wakefield accelerator Turbulence and transport in mirror geometries in the Large Plasma Device Wave Steepening and Shock Formation in Ultracold Neutral Plasmas Limitations from charge quantization on the parallel temperature diagnostic of nonneutral plasmas An Extended Variational Method for the Resistive Wall Mode in Toroidal Plasma Confinement Devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1