{"title":"Is bicortical femoral pin insertion safe for Image-based Robotic Knee Arthroplasty Surgery ? A comparative complications analysis in 970 Consecutive Cases.","authors":"Christos Koutserimpas,Clément Favroul,Cécile Batailler,Elvire Servien,Sébastien Lustig","doi":"10.1016/j.jisako.2024.100317","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\r\nLimited data exists on complications associated with robotic image-based system in knee arthroplasty. This study aims to document complications in robotic arm-assisted knee arthroplasties, and evaluate the system's safety by comparing two femoral pin insertion methods: bicortical diaphyseal with additional stab wounds, and unicortical metaphyseal placement through the main incision.\r\n\r\nMETHODS\r\nAll patients undergoing primary knee arthroplasty with the image-based robotic system (Mako, Stryker, Mako Surgical Corp., Fort Lauderdale, FL, USA) from 1st March 2021 to 31st January 2024 with a minimum follow-up of 2 months were included. Demographics, system and non-system-related complications, as well as outcomes were recorded. Complications were categorized as either major (requiring a second surgical intervention) or minor.\r\n\r\nRESULTS\r\nA total of 970 consecutive cases (median age 69.3 years) were analyzed. The unicortical group comprised 651 cases, while the bicortical group 319. The incidence of non-system-related complications was 2.37%, with the most common being joint stiffness (10 cases; 1.03%), followed by lateral femoral condyle fracture (4;0.41%). The overall incidence of system-specific complications was 1.03%. Pin-related femoral fractures occurred in 0.2% of cases, all postoperatively and in the unicortical group. There was no statistically significant difference between the femoral pin insertion-related complication rates among the two groups (0.3% in the unicortical, compared to 0% in the bicortical group; p-value= 0.3). Complications included tibia fracture (0.1%), delayed wound healing (0.2%), superficial wound infection (0.1%), tibia osteomyelitis (0.1%), and \"exostosis\" (0.2%). The major complications rate was 0.3% and minor 0.7%.\r\n\r\nCONCLUSIONS\r\nMinimal system-specific overall complications indicate that robotic arm-assisted surgery is safe. The bicortical diaphyseal femoral pin insertion method does not increase the complication rates compared to the unicortical metaphyseal method.\r\n\r\nLEVEL OF EVIDENCE\r\nIII.","PeriodicalId":501663,"journal":{"name":"Journal of ISAKOS","volume":"170 1","pages":"100317"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of ISAKOS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.jisako.2024.100317","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
OBJECTIVES
Limited data exists on complications associated with robotic image-based system in knee arthroplasty. This study aims to document complications in robotic arm-assisted knee arthroplasties, and evaluate the system's safety by comparing two femoral pin insertion methods: bicortical diaphyseal with additional stab wounds, and unicortical metaphyseal placement through the main incision.
METHODS
All patients undergoing primary knee arthroplasty with the image-based robotic system (Mako, Stryker, Mako Surgical Corp., Fort Lauderdale, FL, USA) from 1st March 2021 to 31st January 2024 with a minimum follow-up of 2 months were included. Demographics, system and non-system-related complications, as well as outcomes were recorded. Complications were categorized as either major (requiring a second surgical intervention) or minor.
RESULTS
A total of 970 consecutive cases (median age 69.3 years) were analyzed. The unicortical group comprised 651 cases, while the bicortical group 319. The incidence of non-system-related complications was 2.37%, with the most common being joint stiffness (10 cases; 1.03%), followed by lateral femoral condyle fracture (4;0.41%). The overall incidence of system-specific complications was 1.03%. Pin-related femoral fractures occurred in 0.2% of cases, all postoperatively and in the unicortical group. There was no statistically significant difference between the femoral pin insertion-related complication rates among the two groups (0.3% in the unicortical, compared to 0% in the bicortical group; p-value= 0.3). Complications included tibia fracture (0.1%), delayed wound healing (0.2%), superficial wound infection (0.1%), tibia osteomyelitis (0.1%), and "exostosis" (0.2%). The major complications rate was 0.3% and minor 0.7%.
CONCLUSIONS
Minimal system-specific overall complications indicate that robotic arm-assisted surgery is safe. The bicortical diaphyseal femoral pin insertion method does not increase the complication rates compared to the unicortical metaphyseal method.
LEVEL OF EVIDENCE
III.