Advances in the Goertzel Filter Bank Channelizer for Cryogenic Sensors Readout

IF 1.1 3区 物理与天体物理 Q4 PHYSICS, APPLIED Journal of Low Temperature Physics Pub Date : 2024-09-12 DOI:10.1007/s10909-024-03204-z
L. P. Ferreyro, M. E. García Redondo, J. M. Salum, T. Muscheid, M. Hampel, A. Almela, A. Fuster, J. M. Geria, J. Bonaparte, J. Bonilla-Neira, L. E. Ardila-Perez, R. Gartmann, N. Müller, M. Wegner, O. Sander, M. Platino, S. Kempf, A. Etchegoyen, M. Weber
{"title":"Advances in the Goertzel Filter Bank Channelizer for Cryogenic Sensors Readout","authors":"L. P. Ferreyro,&nbsp;M. E. García Redondo,&nbsp;J. M. Salum,&nbsp;T. Muscheid,&nbsp;M. Hampel,&nbsp;A. Almela,&nbsp;A. Fuster,&nbsp;J. M. Geria,&nbsp;J. Bonaparte,&nbsp;J. Bonilla-Neira,&nbsp;L. E. Ardila-Perez,&nbsp;R. Gartmann,&nbsp;N. Müller,&nbsp;M. Wegner,&nbsp;O. Sander,&nbsp;M. Platino,&nbsp;S. Kempf,&nbsp;A. Etchegoyen,&nbsp;M. Weber","doi":"10.1007/s10909-024-03204-z","DOIUrl":null,"url":null,"abstract":"<div><p>Neutrino mass estimation experiments and cosmic microwave background (CMB) radiation surveys both employ low-temperature detectors (LTD) known as calorimeters and bolometers, respectively. These detectors operate typically between 10 and 300 mK. LTDs multiplexed by means of a microwave superconducting quantum interference device multiplexer (µMUX) demonstrated to be an excellent device for the readout of several detectors in the microwave region. This entails generating a multi-tonal signal and its subsequent readout. A single-tone detection method based on a Goertzel filter bank (GFB) channelizer was used for the readout of the aforementioned signal, implemented in a software-defined radio readout architecture within a field-programmable gate array. The measurements presented here demonstrate remarkable results in validating the suitability of the GFB channelizer for this system.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"217 Part 4","pages":"409 - 417"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10909-024-03204-z.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-024-03204-z","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Neutrino mass estimation experiments and cosmic microwave background (CMB) radiation surveys both employ low-temperature detectors (LTD) known as calorimeters and bolometers, respectively. These detectors operate typically between 10 and 300 mK. LTDs multiplexed by means of a microwave superconducting quantum interference device multiplexer (µMUX) demonstrated to be an excellent device for the readout of several detectors in the microwave region. This entails generating a multi-tonal signal and its subsequent readout. A single-tone detection method based on a Goertzel filter bank (GFB) channelizer was used for the readout of the aforementioned signal, implemented in a software-defined radio readout architecture within a field-programmable gate array. The measurements presented here demonstrate remarkable results in validating the suitability of the GFB channelizer for this system.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于低温传感器读数的 Goertzel 滤波器组通道器的进展
中微子质量估算实验和宇宙微波背景(CMB)辐射测量都采用了低温探测器(LTD),分别称为热量计和波长计。这些探测器的工作温度通常在 10 到 300 mK 之间。通过微波超导量子干涉装置复用器(µMUX)复用的低温探测器被证明是在微波区域读出多个探测器的绝佳设备。这就需要产生一个多音调信号,然后进行读出。在现场可编程门阵列的软件定义无线电读出架构中,使用了基于戈尔策尔滤波器组(GFB)信道器的单音检测方法来读出上述信号。本文介绍的测量结果表明,GFB 信道器在验证该系统的适用性方面取得了显著成效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Low Temperature Physics
Journal of Low Temperature Physics 物理-物理:凝聚态物理
CiteScore
3.30
自引率
25.00%
发文量
245
审稿时长
1 months
期刊介绍: The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.
期刊最新文献
Enhanced Stability of Self-Bound Droplets in Quasi-One Dimension via Interspecies Quantum Fluctuations in Ultracold Bose–Bose Mixtures Superconductivity in Alkali Metal-Deposited Monolayer BC: MBC (M = Na, K) On the Superstatistical Properties of the Klein-Gordon Oscillator Using Gamma, Log, and F Distributions The Magnetic Microbolometer Detection Chain: A Proposed Detection System to Observe the B Modes of the Cosmic Microwave Background Tutorial: From Topology to Hall Effects—Implications of Berry Phase Physics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1