{"title":"The Analysis of Odd Triple Harmonics to Detect Broken Rotor Bar in Delta-Connected Induction Motors","authors":"Ruhan Pontes Policarpo de Souza;Daniel Morinigo-Sotelo;Vanesa Fernandez-Cavero;Óscar Duque-Perez;Cristiano Marcos Agulhari;Alessandro Goedtel","doi":"10.1109/TIA.2024.3447632","DOIUrl":null,"url":null,"abstract":"This paper aims to use and explore odd triple harmonics to perform fault detection in delta-connected induction motors, demonstrating their suitability to detect broken rotor bars. Harmonic components arise around the main odd triple components, generated by the interaction of the fault and other effects, such as saturation and voltage unbalance. The paper presents the mathematical modeling introducing the harmonic components, along with experimental results under several load levels, voltage unbalanced, and under inverter-fed power supply, demonstrating the effectiveness of the detection of the odd triple harmonics. The results compare line and phase currents, demonstrating that the proposed harmonics perform satisfactorily in phase current, suitable for fault detection in a wide operating range, including low-load cases.","PeriodicalId":13337,"journal":{"name":"IEEE Transactions on Industry Applications","volume":"60 6","pages":"8736-8744"},"PeriodicalIF":4.2000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Industry Applications","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10643698/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
This paper aims to use and explore odd triple harmonics to perform fault detection in delta-connected induction motors, demonstrating their suitability to detect broken rotor bars. Harmonic components arise around the main odd triple components, generated by the interaction of the fault and other effects, such as saturation and voltage unbalance. The paper presents the mathematical modeling introducing the harmonic components, along with experimental results under several load levels, voltage unbalanced, and under inverter-fed power supply, demonstrating the effectiveness of the detection of the odd triple harmonics. The results compare line and phase currents, demonstrating that the proposed harmonics perform satisfactorily in phase current, suitable for fault detection in a wide operating range, including low-load cases.
期刊介绍:
The scope of the IEEE Transactions on Industry Applications includes all scope items of the IEEE Industry Applications Society, that is, the advancement of the theory and practice of electrical and electronic engineering in the development, design, manufacture, and application of electrical systems, apparatus, devices, and controls to the processes and equipment of industry and commerce; the promotion of safe, reliable, and economic installations; industry leadership in energy conservation and environmental, health, and safety issues; the creation of voluntary engineering standards and recommended practices; and the professional development of its membership.