Does Sagittal Alignment Matter? A Biomechanical Look at Pinning Pediatric Supracondylar Humerus Fractures.

IF 1.4 3区 医学 Q3 ORTHOPEDICS Journal of Pediatric Orthopaedics Pub Date : 2024-09-10 DOI:10.1097/bpo.0000000000002809
Ryan Serbin,Marc Duemmler,Kirby Bonvillain,Kelsie Coe,Nahir A Habet,Susan Odum,Michael Paloski
{"title":"Does Sagittal Alignment Matter? A Biomechanical Look at Pinning Pediatric Supracondylar Humerus Fractures.","authors":"Ryan Serbin,Marc Duemmler,Kirby Bonvillain,Kelsie Coe,Nahir A Habet,Susan Odum,Michael Paloski","doi":"10.1097/bpo.0000000000002809","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\r\nClosed manipulation and percutaneous pinning is standard of care for displaced supracondylar humerus fractures, yet the optimal pin configuration, particularly in the sagittal plane, is not well defined. This study evaluates how sagittal plane pin variations affect construct strength biomechanically.\r\n\r\nMETHODS\r\nOne hundred synthetic pediatric humerus models were used to emulate supracondylar humerus fracture. The models were pinned using 4 different configurations uniformly divergent in the coronal plane with variations in the sagittal plane: (1) 2 diverging pins with the lateral pin anterior (n = 25), (2) 2 diverging pins with the lateral pin posterior (n = 25), (3) 2 parallel pins (n = 25), and (4) 3 parallel pins (n = 25). The models were tested under bending (flexion, extension, and varus) and rotational (internal and external) forces, measuring stiffness and torque. Statistical analyses identified significant differences across configurations.\r\n\r\nRESULTS\r\nThe 2-pin parallel configuration (9.68 N/mm in extension, 8.76 N/mm in flexion, 0.14 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation) performed similarly to the 3-pin parallel setup (10.77 N/mm in extension, 7.78 N/mm in flexion, 0.16 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation), with no significant differences in stiffness. In contrast, both parallel configurations significantly outperformed the 2-pin anterior (5.22 N/mm in extension, 5.7 N/mm in flexion, 0.11 N-m/deg in internal rotation and 0.10 N-m/deg in external rotation) and posterior (9.86 N/mm in extension, 8.31 N/mm in flexion, 0.12N-m/deg in internal rotation, and 0.11 N-m/deg in external rotation) configurations in resisting deformation. No notable disparities were observed in varus loading among any configurations.\r\n\r\nCONCLUSIONS\r\nThis study illuminates the sagittal plane's role in construct stability. It suggests that, when utilizing 2-pins, parallel configurations in the sagittal plane improve biomechanical stability. In addition, it suggests avoiding the lateral anterior pin configuration due to its biomechanical inferiority. Further research should assess ultimate strength and compare various 3-pin configurations to better delineate differences between 2-pin and 3-pin configurations regarding sagittal plane alignment.\r\n\r\nLEVEL OF EVIDENCE\r\nLevel III-biomechanical study.","PeriodicalId":16945,"journal":{"name":"Journal of Pediatric Orthopaedics","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/bpo.0000000000002809","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVE Closed manipulation and percutaneous pinning is standard of care for displaced supracondylar humerus fractures, yet the optimal pin configuration, particularly in the sagittal plane, is not well defined. This study evaluates how sagittal plane pin variations affect construct strength biomechanically. METHODS One hundred synthetic pediatric humerus models were used to emulate supracondylar humerus fracture. The models were pinned using 4 different configurations uniformly divergent in the coronal plane with variations in the sagittal plane: (1) 2 diverging pins with the lateral pin anterior (n = 25), (2) 2 diverging pins with the lateral pin posterior (n = 25), (3) 2 parallel pins (n = 25), and (4) 3 parallel pins (n = 25). The models were tested under bending (flexion, extension, and varus) and rotational (internal and external) forces, measuring stiffness and torque. Statistical analyses identified significant differences across configurations. RESULTS The 2-pin parallel configuration (9.68 N/mm in extension, 8.76 N/mm in flexion, 0.14 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation) performed similarly to the 3-pin parallel setup (10.77 N/mm in extension, 7.78 N/mm in flexion, 0.16 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation), with no significant differences in stiffness. In contrast, both parallel configurations significantly outperformed the 2-pin anterior (5.22 N/mm in extension, 5.7 N/mm in flexion, 0.11 N-m/deg in internal rotation and 0.10 N-m/deg in external rotation) and posterior (9.86 N/mm in extension, 8.31 N/mm in flexion, 0.12N-m/deg in internal rotation, and 0.11 N-m/deg in external rotation) configurations in resisting deformation. No notable disparities were observed in varus loading among any configurations. CONCLUSIONS This study illuminates the sagittal plane's role in construct stability. It suggests that, when utilizing 2-pins, parallel configurations in the sagittal plane improve biomechanical stability. In addition, it suggests avoiding the lateral anterior pin configuration due to its biomechanical inferiority. Further research should assess ultimate strength and compare various 3-pin configurations to better delineate differences between 2-pin and 3-pin configurations regarding sagittal plane alignment. LEVEL OF EVIDENCE Level III-biomechanical study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
矢状对齐重要吗?从生物力学角度看小儿肱骨髁上骨折的钢钉固定。
目的闭合操作和经皮置入钢钉是治疗移位肱骨髁上骨折的标准方法,但最佳的钢钉配置,尤其是矢状面上的钢钉配置,尚未得到很好的定义。本研究评估了矢状面针的变化对生物力学结构强度的影响。方法用 100 个合成小儿肱骨模型模拟肱骨髁上骨折。这些模型采用四种不同的结构进行固定,这些结构在冠状面上均匀发散,而在矢状面上有所变化:(1) 2个发散针,侧针在前方(n = 25);(2) 2个发散针,侧针在后方(n = 25);(3) 2个平行针(n = 25);(4) 3个平行针(n = 25)。这些模型在弯曲(屈曲、伸展和外翻)和旋转(内部和外部)力作用下进行了测试,测量了硬度和扭矩。结果2针平行配置(伸展时9.68 N/mm,屈曲时8.76 N/mm,内旋时0.14 N-m/deg,外旋时0.14 N-m/deg)与3针平行配置(伸展时10.77 N/mm,屈曲时7.78 N/mm,内旋时0.16 N-m/deg,外旋时0.14 N-m/deg)性能相似,刚度无显著差异。相比之下,两种平行结构在抵抗变形方面明显优于双针前结构(伸展5.22 N/mm,屈曲5.7 N/mm,内旋0.11 N-m/deg,外旋0.10 N-m/deg)和后结构(伸展9.86 N/mm,屈曲8.31 N/mm,内旋0.12 N-m/deg,外旋0.11 N-m/deg)。本研究阐明了矢状面在结构稳定性中的作用。该研究表明,在使用 2 针时,矢状面上的平行配置可提高生物力学稳定性。此外,它还建议避免使用外侧前方针脚配置,因为这种配置在生物力学上效果较差。进一步的研究应评估终极强度并比较各种 3 针配置,以更好地界定 2 针和 3 针配置在矢状面对齐方面的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.30
自引率
17.60%
发文量
512
审稿时长
6 months
期刊介绍: ​Journal of Pediatric Orthopaedics is a leading journal that focuses specifically on traumatic injuries to give you hands-on on coverage of a fast-growing field. You''ll get articles that cover everything from the nature of injury to the effects of new drug therapies; everything from recommendations for more effective surgical approaches to the latest laboratory findings.
期刊最新文献
Triple Pelvic Osteotomy for Hip Dysplasia: The Akbulut-Coskun Technique Using a Modified Stoppa Approach. Analysis of Serial Foot Radiographs to Determine Foot Height Multipliers. Long-term Clinical and Radiographic Results of Posteromedial Lateral Release for Neuromuscular Clubfoot Deformity. Injuries Following COVID-19 Infection in Academy-level Male Youth Soccer Players. What is the Utilization and Impact of Advanced Imaging for Tibial Tubercle Fractures? An Analysis of 598 Patients From the Tibial Tubercle Study (TITUS) Group.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1