{"title":"Enhanced peroxidase‐like activity of MnFe2O4 nanoparticles on halloysite nanotubes for uric acid detection","authors":"Hengxia Shen, Zhenbo Xiang, Anfang Dang","doi":"10.1002/apj.3143","DOIUrl":null,"url":null,"abstract":"Nanozymes have significantly advanced sensing assays by replicating native enzyme functions. However, designing nanozymes with high catalytic activity and easy recyclability remains challenging. The study presented here has resulted in the development of a highly efficient and sensitive colorimetric system for the detection of uric acid, utilizing MnFe<jats:sub>2</jats:sub>O<jats:sub>4</jats:sub>@HNTs—a novel composite material consisting of MnFe<jats:sub>2</jats:sub>O<jats:sub>4</jats:sub> loaded onto halloysite nanotubes. These nanocomposites exhibited outstanding peroxidase‐like activity and attractive magnetic properties. The catalytic efficiency of the MnFe<jats:sub>2</jats:sub>O<jats:sub>4</jats:sub>@HNTs in the oxidation of 3,3′,5,5′‐tetramethylbenzidine, in the presence of H<jats:sub>2</jats:sub>O<jats:sub>2</jats:sub>, was remarkable, leading to a distinct color change from colorless to blue. A linear relationship was observed between absorbance and UA concentration in the range of 1–20 μM, with a detection limit as low as 52 nM. Mechanistic investigations revealed that reactive oxygen species (ROS), specifically singlet oxygen (<jats:sup>1</jats:sup>O<jats:sub>2</jats:sub>), were generated through the decomposition of H<jats:sub>2</jats:sub>O<jats:sub>2</jats:sub>, which is responsible for the peroxidase‐like activity demonstrated by the MnFe<jats:sub>2</jats:sub>O<jats:sub>4</jats:sub>@HNTs. The method showed minimal interference from serum substances and high selectivity. Magnetic MnFe<jats:sub>2</jats:sub>O<jats:sub>4</jats:sub> allowed easy separation and maintained over 95% activity after seven reuse cycles. The developed assay was successfully applied to the detection of uric acid in human serum, achieving recoveries greater than 98.60%. This research significantly advances the design of recyclable high‐performance nanozymes and establishes an effective colorimetric sensing platform for UA detection in clinical samples, potentially improving diagnostic tools for healthcare applications.","PeriodicalId":8852,"journal":{"name":"Asia-Pacific Journal of Chemical Engineering","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Chemical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/apj.3143","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemical Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
Nanozymes have significantly advanced sensing assays by replicating native enzyme functions. However, designing nanozymes with high catalytic activity and easy recyclability remains challenging. The study presented here has resulted in the development of a highly efficient and sensitive colorimetric system for the detection of uric acid, utilizing MnFe2O4@HNTs—a novel composite material consisting of MnFe2O4 loaded onto halloysite nanotubes. These nanocomposites exhibited outstanding peroxidase‐like activity and attractive magnetic properties. The catalytic efficiency of the MnFe2O4@HNTs in the oxidation of 3,3′,5,5′‐tetramethylbenzidine, in the presence of H2O2, was remarkable, leading to a distinct color change from colorless to blue. A linear relationship was observed between absorbance and UA concentration in the range of 1–20 μM, with a detection limit as low as 52 nM. Mechanistic investigations revealed that reactive oxygen species (ROS), specifically singlet oxygen (1O2), were generated through the decomposition of H2O2, which is responsible for the peroxidase‐like activity demonstrated by the MnFe2O4@HNTs. The method showed minimal interference from serum substances and high selectivity. Magnetic MnFe2O4 allowed easy separation and maintained over 95% activity after seven reuse cycles. The developed assay was successfully applied to the detection of uric acid in human serum, achieving recoveries greater than 98.60%. This research significantly advances the design of recyclable high‐performance nanozymes and establishes an effective colorimetric sensing platform for UA detection in clinical samples, potentially improving diagnostic tools for healthcare applications.
期刊介绍:
Asia-Pacific Journal of Chemical Engineering is aimed at capturing current developments and initiatives in chemical engineering related and specialised areas. Publishing six issues each year, the journal showcases innovative technological developments, providing an opportunity for technology transfer and collaboration.
Asia-Pacific Journal of Chemical Engineering will focus particular attention on the key areas of: Process Application (separation, polymer, catalysis, nanotechnology, electrochemistry, nuclear technology); Energy and Environmental Technology (materials for energy storage and conversion, coal gasification, gas liquefaction, air pollution control, water treatment, waste utilization and management, nuclear waste remediation); and Biochemical Engineering (including targeted drug delivery applications).