Regression prediction model for shear strength of cold joint in concrete

IF 3.9 2区 工程技术 Q1 ENGINEERING, CIVIL Structures Pub Date : 2024-09-03 DOI:10.1016/j.istruc.2024.107168
Ziqin Zhong, Shixing Zhao, Jing Xia, Qirui Luo, Qiaoling Zhou, Shuheng Yang, Fei He, Yu Yao
{"title":"Regression prediction model for shear strength of cold joint in concrete","authors":"Ziqin Zhong, Shixing Zhao, Jing Xia, Qirui Luo, Qiaoling Zhou, Shuheng Yang, Fei He, Yu Yao","doi":"10.1016/j.istruc.2024.107168","DOIUrl":null,"url":null,"abstract":"The shear resistance of cold joint in concrete is influenced by various design parameters. Traditional mechanical models typically consider only a limited number of parameters to predict the shear strength of cold joints. This research aims to explore the complex nonlinear relationship between design parameters and cold joint shear strength using statistical method and machine learning technology. The goal is to develop a more accurate, reliable, and engineering applicable regression model for predicting shear strength. A dataset of 546 Z-shaped shear specimens characterizing cold joint in concrete was constructed, involving a total of 16 variables that may affect shear performance. Correlation analysis and recursive elimination were adopted to eliminate correlated and insignificant variables based on their importance. Multiple linear regression (MLR), random forest regression (RFR), and support vector machine regression (SVR) prediction models for cold joint shear strength were established based on rigorously screened variables and comprehensively evaluated using multiple methods. It was found that the most significant factors influencing the shear strength of cold joints are concrete strength, interface shear key, product of interface reinforcement strength and its reinforcement ratio, normal stress, fiber length of new concrete, casting method of the new concrete, and product of the fiber length and its tensile strength of old concrete. The MLR, SVR, and RFR models all exhibited superior performance relative to traditional mechanics-based models with regard to shear strength prediction of cold joints. The RFR model is recommended for predicting the shear strength of cold joints due to its superior evaluation indexes in comparison to the MLR and SVR models, and variable sensitivity analysis shows that it does not yield common-sense errors.","PeriodicalId":48642,"journal":{"name":"Structures","volume":null,"pages":null},"PeriodicalIF":3.9000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1016/j.istruc.2024.107168","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

The shear resistance of cold joint in concrete is influenced by various design parameters. Traditional mechanical models typically consider only a limited number of parameters to predict the shear strength of cold joints. This research aims to explore the complex nonlinear relationship between design parameters and cold joint shear strength using statistical method and machine learning technology. The goal is to develop a more accurate, reliable, and engineering applicable regression model for predicting shear strength. A dataset of 546 Z-shaped shear specimens characterizing cold joint in concrete was constructed, involving a total of 16 variables that may affect shear performance. Correlation analysis and recursive elimination were adopted to eliminate correlated and insignificant variables based on their importance. Multiple linear regression (MLR), random forest regression (RFR), and support vector machine regression (SVR) prediction models for cold joint shear strength were established based on rigorously screened variables and comprehensively evaluated using multiple methods. It was found that the most significant factors influencing the shear strength of cold joints are concrete strength, interface shear key, product of interface reinforcement strength and its reinforcement ratio, normal stress, fiber length of new concrete, casting method of the new concrete, and product of the fiber length and its tensile strength of old concrete. The MLR, SVR, and RFR models all exhibited superior performance relative to traditional mechanics-based models with regard to shear strength prediction of cold joints. The RFR model is recommended for predicting the shear strength of cold joints due to its superior evaluation indexes in comparison to the MLR and SVR models, and variable sensitivity analysis shows that it does not yield common-sense errors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
混凝土冷缝抗剪强度回归预测模型
混凝土冷接缝的抗剪性能受各种设计参数的影响。传统的力学模型通常只考虑有限的参数来预测冷接缝的抗剪强度。本研究旨在利用统计方法和机器学习技术探索设计参数与冷接缝抗剪强度之间复杂的非线性关系。目标是开发出一种更准确、更可靠、更适用于工程的回归模型,用于预测剪切强度。我们构建了一个包含 546 个 Z 型剪切试件的数据集,这些试件表征了混凝土冷接缝的特性,共涉及 16 个可能影响剪切性能的变量。根据变量的重要性,采用相关分析和递归剔除法剔除相关和不重要的变量。在严格筛选变量的基础上,建立了冷接缝抗剪强度的多元线性回归(MLR)、随机森林回归(RFR)和支持向量机回归(SVR)预测模型,并采用多种方法进行了综合评估。结果发现,影响冷缝抗剪强度的最主要因素是混凝土强度、界面剪力键、界面钢筋强度与其配筋率的乘积、法向应力、新混凝土的纤维长度、新混凝土的浇筑方法以及旧混凝土的纤维长度与其抗拉强度的乘积。与传统的力学模型相比,MLR、SVR 和 RFR 模型在冷接缝剪切强度预测方面都表现出更优越的性能。由于 RFR 模型的评价指标优于 MLR 和 SVR 模型,且变量敏感性分析表明 RFR 模型不会产生常识性误差,因此推荐使用 RFR 模型预测冷接缝的抗剪强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Structures
Structures Engineering-Architecture
CiteScore
5.70
自引率
17.10%
发文量
1187
期刊介绍: Structures aims to publish internationally-leading research across the full breadth of structural engineering. Papers for Structures are particularly welcome in which high-quality research will benefit from wide readership of academics and practitioners such that not only high citation rates but also tangible industrial-related pathways to impact are achieved.
期刊最新文献
Experimental study on acoustic emission damage in precast reinforced concrete interior joints containing disc springs Experimental and numerical studies on the mechanical behavior of metallic connecting pieces in point-supported glass facades A new cross section hypothesis-based approach for quantifying deployment characteristics of deployable inflatable structures Numerical study on seismic performance of a prefabricated subway station considering the influence of construction process Investigation on shear performance of sliding-type rapid segmental joints for shield tunnels
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1