Does Monopolar Electrocautery Affect the Fetus during Cesarean Section?

Q4 Medicine Medicina Pub Date : 2024-09-05 DOI:10.3390/medicina60091453
Sevki Goksun Gokulu, Hamza Yildiz, Ali Yildizbakan, Gorkem Ulger, Huseyin Durukan, Yalcin Celik, Hakan Aytan
{"title":"Does Monopolar Electrocautery Affect the Fetus during Cesarean Section?","authors":"Sevki Goksun Gokulu, Hamza Yildiz, Ali Yildizbakan, Gorkem Ulger, Huseyin Durukan, Yalcin Celik, Hakan Aytan","doi":"10.3390/medicina60091453","DOIUrl":null,"url":null,"abstract":"Background and Objectives: This study aimed to assess the impact of monopolar electrocautery on the fetus during cesarean section. Materials and methods: A retrospective analysis was conducted with 552 patients delivered by cesarean section. Patients were grouped based on usage of monopolar electrocautery. In 272 patients, monopolar electrocautery was used to separate the tissues before the delivery. In 280 patients, no electrocautery was used. Newborn vital signs, Apgar scores, umbilical cord blood parameters, newborn serum parameters collected within 6th postpartum hour, and rate of newborn intensive care unit admission were compared. Results: The 1st and 5th minute Apgar scores were significantly higher in the electrocautery group; however, this difference lost its significance at the 10th minute. The median newborn pulse rate (148 (7) vs. 146 (6) beats per minute, p = 0.026), umbilical cord blood pH, and partial oxygen pressure were significantly higher in the electrocautery group compared to the no-electrocautery group (7.34 ± 0.06 vs. 7.31 ± 0.06, p < 0.001, and 25.5 (14.77) vs. 23 (16.08) mmHg, p = 0.025, respectively). The median umbilical cord blood serum calcium level was 1.51 (0.64) mmol/L in the electrocautery group, which was significantly lower than 1.9 (0.82) mmol/L in the no-electrocautery group (p = 0.002). The incidence of hypoglycemia was significantly lower in the electrocautery group than in the no-electrocautery group (2.2% vs. 5.7%, p = 0.035). Conclusions: Monopolar electrocautery during cesarean section affects the fetus, but it is safe to use it. Electrocautery is independently associated with umbilical cord blood pH and calcium level. Electrocautery may be associated with a lower incidence of hypoglycemia.","PeriodicalId":18512,"journal":{"name":"Medicina","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/medicina60091453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objectives: This study aimed to assess the impact of monopolar electrocautery on the fetus during cesarean section. Materials and methods: A retrospective analysis was conducted with 552 patients delivered by cesarean section. Patients were grouped based on usage of monopolar electrocautery. In 272 patients, monopolar electrocautery was used to separate the tissues before the delivery. In 280 patients, no electrocautery was used. Newborn vital signs, Apgar scores, umbilical cord blood parameters, newborn serum parameters collected within 6th postpartum hour, and rate of newborn intensive care unit admission were compared. Results: The 1st and 5th minute Apgar scores were significantly higher in the electrocautery group; however, this difference lost its significance at the 10th minute. The median newborn pulse rate (148 (7) vs. 146 (6) beats per minute, p = 0.026), umbilical cord blood pH, and partial oxygen pressure were significantly higher in the electrocautery group compared to the no-electrocautery group (7.34 ± 0.06 vs. 7.31 ± 0.06, p < 0.001, and 25.5 (14.77) vs. 23 (16.08) mmHg, p = 0.025, respectively). The median umbilical cord blood serum calcium level was 1.51 (0.64) mmol/L in the electrocautery group, which was significantly lower than 1.9 (0.82) mmol/L in the no-electrocautery group (p = 0.002). The incidence of hypoglycemia was significantly lower in the electrocautery group than in the no-electrocautery group (2.2% vs. 5.7%, p = 0.035). Conclusions: Monopolar electrocautery during cesarean section affects the fetus, but it is safe to use it. Electrocautery is independently associated with umbilical cord blood pH and calcium level. Electrocautery may be associated with a lower incidence of hypoglycemia.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
剖腹产手术中单极电烧对胎儿有影响吗?
背景和目的:本研究旨在评估剖宫产术中单极电烧对胎儿的影响。材料和方法:对 552 例剖宫产患者进行了回顾性分析。根据单极电烧的使用情况对患者进行分组。272例患者在分娩前使用了单极电烧分离组织。280名患者未使用电烧。比较了新生儿生命体征、Apgar 评分、脐带血参数、产后 6 小时内采集的新生儿血清参数以及新生儿重症监护室入院率。结果电灼组在第 1 分钟和第 5 分钟的 Apgar 评分明显更高,但在第 10 分钟时,这种差异失去了意义。电灼组新生儿脉搏中位数(148 (7) vs. 146 (6) 次/分钟,p = 0.026)、脐带血 pH 值和氧分压均显著高于非电灼组(分别为 7.34 ± 0.06 vs. 7.31 ± 0.06,p < 0.001 和 25.5 (14.77) vs. 23 (16.08) mmHg,p = 0.025)。电灼组的脐带血血清钙中位数为 1.51 (0.64) mmol/L,明显低于无电灼组的 1.9 (0.82) mmol/L(p = 0.002)。电灼组的低血糖发生率明显低于无电灼组(2.2% 对 5.7%,p = 0.035)。结论剖宫产术中的单极电烧会影响胎儿,但使用单极电烧是安全的。电烧与脐带血pH值和钙水平无关。电烧可能与低血糖发生率较低有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medicina
Medicina Medicine-Medicine (all)
CiteScore
0.10
自引率
0.00%
发文量
66
审稿时长
24 weeks
期刊介绍: Publicada con el apoyo del Ministerio de Ciencia, Tecnología e Innovación Productiva. Medicina no tiene propósitos comerciales. El objeto de su creación ha sido propender al adelanto de la medicina argentina. Los beneficios que pudieran obtenerse serán aplicados exclusivamente a ese fin.
期刊最新文献
Insights into the Two Most Common Cancers of Primitive Gut-Derived Structures and Their Microbial Connections Intravital Position Study of the Clinical Anatomy of the Middle Lobe and Superior Poles of the Thyroid Gland An Analysis of Emergency Surgical Outcomes for Pediatric Traumatic Brain Injury: A Ten-Year Single-Institute Retrospective Study in Taiwan Evaluation of Left Atrial Electromechanical Delay and Left Atrial Phasic Functions in Patients Undergoing Treatment with Cardiotoxic Chemotherapeutic Agents Self-Reported Gastrointestinal Symptoms Associated with NSAIDs and Caffeine Consumption in a Jordanian Subpopulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1