XP-Endo Finisher behaviour and irrigant temperature in intracanal environment: Clinical measurements

IF 7.1 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International endodontic journal Pub Date : 2024-09-12 DOI:10.1111/iej.14146
Fernanda de Melo Silva, Isabella Figueiredo Assis Macedo, Pedro Damas Resende, Warley Luciano Fonseca Tavares, Vicente Tadeu Lopes Buono, Leandro de Arruda Santos, Isabella Faria da Cunha Peixoto, Ana Cecília Diniz Viana
{"title":"XP-Endo Finisher behaviour and irrigant temperature in intracanal environment: Clinical measurements","authors":"Fernanda de Melo Silva,&nbsp;Isabella Figueiredo Assis Macedo,&nbsp;Pedro Damas Resende,&nbsp;Warley Luciano Fonseca Tavares,&nbsp;Vicente Tadeu Lopes Buono,&nbsp;Leandro de Arruda Santos,&nbsp;Isabella Faria da Cunha Peixoto,&nbsp;Ana Cecília Diniz Viana","doi":"10.1111/iej.14146","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Aim</h3>\n \n <p>To evaluate the behaviour of the XP-Endo Finisher and the variation in the intracanal temperature of the irrigant at rest and when activated over time.</p>\n </section>\n \n <section>\n \n <h3> Methodology</h3>\n \n <p>Differential scanning calorimetry (DSC) determined the transformation temperatures of XP-Endo Finisher instruments. A digital thermocouple was used to measure the temperature of the irrigant inside the pulp chamber. Two measurements were performed for each tooth (<i>n</i> = 12): with the irrigant at rest and during XP-Endo agitation for 60 s to observe the temperature evolution. The data were statistically analysed using a <i>t-</i>test with a confidence level of 95%.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>DSC results suggested that the XP-Endo Finisher had a mixed R-phase and austenitic structure at room temperature. The temperature values at predetermined time points (0, 10, 40, 70, 120 and 240 s) were measured, and no statistical difference was observed between the values of the resting and activated solutions at any of the selected points (<i>p</i> &gt; .05). For the protocol performed with the XP-Endo file, the mean irrigant temperature observed at instrument insertion inside the root canal was 28.65°C. After 60 s of agitation, the temperature was 34.02°C. The solution temperature stabilized inside the canal only after 211 s at 35.5°C. The mean maximum irrigation solution temperature recorded inside the canal was 35.5°C without agitation and after XP-endo agitation (<i>p</i> &gt; .05).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Although the XP-Endo Finisher system does not promote heating of the irrigation solution, file expansion responsible for improved instrument cleaning starts at a temperature below the expected value.</p>\n </section>\n </div>","PeriodicalId":13724,"journal":{"name":"International endodontic journal","volume":"58 1","pages":"141-149"},"PeriodicalIF":7.1000,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International endodontic journal","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/iej.14146","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim

To evaluate the behaviour of the XP-Endo Finisher and the variation in the intracanal temperature of the irrigant at rest and when activated over time.

Methodology

Differential scanning calorimetry (DSC) determined the transformation temperatures of XP-Endo Finisher instruments. A digital thermocouple was used to measure the temperature of the irrigant inside the pulp chamber. Two measurements were performed for each tooth (n = 12): with the irrigant at rest and during XP-Endo agitation for 60 s to observe the temperature evolution. The data were statistically analysed using a t-test with a confidence level of 95%.

Results

DSC results suggested that the XP-Endo Finisher had a mixed R-phase and austenitic structure at room temperature. The temperature values at predetermined time points (0, 10, 40, 70, 120 and 240 s) were measured, and no statistical difference was observed between the values of the resting and activated solutions at any of the selected points (p > .05). For the protocol performed with the XP-Endo file, the mean irrigant temperature observed at instrument insertion inside the root canal was 28.65°C. After 60 s of agitation, the temperature was 34.02°C. The solution temperature stabilized inside the canal only after 211 s at 35.5°C. The mean maximum irrigation solution temperature recorded inside the canal was 35.5°C without agitation and after XP-endo agitation (p > .05).

Conclusions

Although the XP-Endo Finisher system does not promote heating of the irrigation solution, file expansion responsible for improved instrument cleaning starts at a temperature below the expected value.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
XP-Endo Finisher 在龋内环境中的表现和灌洗液温度:临床测量
评估 XP-Endo Finisher 的性能,以及灌洗剂在静止时和激活后随着时间的推移在龋洞内温度的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International endodontic journal
International endodontic journal 医学-牙科与口腔外科
CiteScore
10.20
自引率
28.00%
发文量
195
审稿时长
4-8 weeks
期刊介绍: The International Endodontic Journal is published monthly and strives to publish original articles of the highest quality to disseminate scientific and clinical knowledge; all manuscripts are subjected to peer review. Original scientific articles are published in the areas of biomedical science, applied materials science, bioengineering, epidemiology and social science relevant to endodontic disease and its management, and to the restoration of root-treated teeth. In addition, review articles, reports of clinical cases, book reviews, summaries and abstracts of scientific meetings and news items are accepted. The International Endodontic Journal is essential reading for general dental practitioners, specialist endodontists, research, scientists and dental teachers.
期刊最新文献
Guided Cavity Preparation to Access an Invagination and Preserve Pulp Vitality of an Immature Maxillary Lateral Incisor With Type IIIa Dens Invaginatus: Technical Overview and a Case Report With 3-Year Follow-Up. Restoring Cell-Cell Junctions in DSPP-Deficient Odontoblasts Through Nanofibrous Topography and Wnt5a-Cdc42 Activation: A Laboratory Investigation. Feasibility and Precision of Robot-Assisted Autotransplantation of Teeth: An In Vitro Study. NLRP1 as a Novel Pyroptosis Biomarker in Irreversible Pulpitis: A Laboratory Investigation and Animal Model Study. Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1