Influence of dimensional deviation and thickness non-uniformity on the small-size specimen tensile results of CLF-1 steel

IF 1.9 3区 工程技术 Q1 NUCLEAR SCIENCE & TECHNOLOGY Fusion Engineering and Design Pub Date : 2024-09-13 DOI:10.1016/j.fusengdes.2024.114673
Shushan Cui , Lifeng He , Xinfu He , Jiru Zhong , Bin Long , Dongli Zou
{"title":"Influence of dimensional deviation and thickness non-uniformity on the small-size specimen tensile results of CLF-1 steel","authors":"Shushan Cui ,&nbsp;Lifeng He ,&nbsp;Xinfu He ,&nbsp;Jiru Zhong ,&nbsp;Bin Long ,&nbsp;Dongli Zou","doi":"10.1016/j.fusengdes.2024.114673","DOIUrl":null,"url":null,"abstract":"<div><p>Tensile testing of small-size specimens has been widely used to evaluate the influence of neutron irradiation on the mechanical properties for structural materials of fusion reactors. In recent years, researchers have been trying to standardize small-size specimen tensile test method. In the present paper, we have investigated the influence of dimensional deviation and thickness non-uniformity on the tensile results of small-size specimen by both experiments and finite element simulations, based on one of the candidate structural materials of fusion reactor, <em>i.e.</em> CLF-1 steel. It was found that under the conditions of small grain size, small metallurgical defect size and suitable specimen preparation, the tensile results of SS-J3 specimen could be close to the results of large-size specimen. Slightly higher yield and ultimate strengths for small specimens may be caused by the surface treatment of the wheel grinding. The repeatability of ultimate strength was better than that of yield strength, and the repeatability of elongation was worse than that of strength. For tensile tests on eight SS-J3 specimens, the maximum difference in total elongation was about 3 %. With ±0.1 mm deviation of thickness and parallel width, the maximum variation in total elongation was about 1.8 %. The ductility properties were sensitive to specimen's thickness non-uniformity, the measured uniform and total elongations would obviously decrease even with 0.01 mm thickness non-uniformity.</p></div>","PeriodicalId":55133,"journal":{"name":"Fusion Engineering and Design","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fusion Engineering and Design","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0920379624005246","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Tensile testing of small-size specimens has been widely used to evaluate the influence of neutron irradiation on the mechanical properties for structural materials of fusion reactors. In recent years, researchers have been trying to standardize small-size specimen tensile test method. In the present paper, we have investigated the influence of dimensional deviation and thickness non-uniformity on the tensile results of small-size specimen by both experiments and finite element simulations, based on one of the candidate structural materials of fusion reactor, i.e. CLF-1 steel. It was found that under the conditions of small grain size, small metallurgical defect size and suitable specimen preparation, the tensile results of SS-J3 specimen could be close to the results of large-size specimen. Slightly higher yield and ultimate strengths for small specimens may be caused by the surface treatment of the wheel grinding. The repeatability of ultimate strength was better than that of yield strength, and the repeatability of elongation was worse than that of strength. For tensile tests on eight SS-J3 specimens, the maximum difference in total elongation was about 3 %. With ±0.1 mm deviation of thickness and parallel width, the maximum variation in total elongation was about 1.8 %. The ductility properties were sensitive to specimen's thickness non-uniformity, the measured uniform and total elongations would obviously decrease even with 0.01 mm thickness non-uniformity.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
尺寸偏差和厚度不均匀对 CLF-1 钢小尺寸试样拉伸结果的影响
小尺寸试样拉伸试验已被广泛用于评估中子辐照对聚变反应堆结构材料力学性能的影响。近年来,研究人员一直在尝试将小尺寸试样拉伸试验方法标准化。本文以聚变堆候选结构材料之一的 CLF-1 钢为例,通过实验和有限元模拟研究了尺寸偏差和厚度不均匀对小尺寸试样拉伸结果的影响。结果发现,在晶粒尺寸小、冶金缺陷尺寸小和试样制备合适的条件下,SS-J3 试样的拉伸结果可以接近大尺寸试样的结果。小尺寸试样的屈服强度和极限强度略高,可能是由于砂轮磨削的表面处理造成的。极限强度的重复性比屈服强度的重复性好,而伸长率的重复性比强度的重复性差。在 8 个 SS-J3 试样的拉伸试验中,总伸长率的最大差异约为 3%。在厚度和平行宽度偏差为±0.1毫米的情况下,总伸长率的最大差异约为1.8%。延展性能对试样厚度不均匀很敏感,即使厚度不均匀度为 0.01 毫米,测得的均匀伸长率和总伸长率也会明显下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Fusion Engineering and Design
Fusion Engineering and Design 工程技术-核科学技术
CiteScore
3.50
自引率
23.50%
发文量
275
审稿时长
3.8 months
期刊介绍: The journal accepts papers about experiments (both plasma and technology), theory, models, methods, and designs in areas relating to technology, engineering, and applied science aspects of magnetic and inertial fusion energy. Specific areas of interest include: MFE and IFE design studies for experiments and reactors; fusion nuclear technologies and materials, including blankets and shields; analysis of reactor plasmas; plasma heating, fuelling, and vacuum systems; drivers, targets, and special technologies for IFE, controls and diagnostics; fuel cycle analysis and tritium reprocessing and handling; operations and remote maintenance of reactors; safety, decommissioning, and waste management; economic and environmental analysis of components and systems.
期刊最新文献
Direct internal recycling fractions approaching unity Experimental study on the critical current in highly flexible REBCO cables under copper tube compaction Parametric study of liquid metal flows in conducting circular ducts in a strong nonuniform magnetic field Thermal hydraulic and material analysis of upgraded flat-type Graphite divertor mock-up for Pakistan Spherical Tokamak (PST) Numerical structural analysis and flow-induced vibration study in support of the design of the EU-DEMO once-through steam generator mock-up for the STEAM experimental facility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1