{"title":"An initial exploration of factors that may impact radiographer performance in reporting mammograms","authors":"","doi":"10.1016/j.radi.2024.09.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>In the United Kingdom, radiographers with a qualification in image interpretation have interpreted mammograms since 1995. These radiographers work under the title of radiography advanced practitioners (RAP) or Consultant Radiographer. This study extends upon what has been very recently published by exploring further clinical, non-clinical and experiential factors that may impact the reporting performance of RAPs.</p></div><div><h3>Methods</h3><p>Fifteen RAPs interpreted an image test set of 60 2D mammograms of known truth using the Detected-X software platform. Unknown to the reader, twenty cases contained a malignancy. Sensitivity, specificity, lesion sensitivity, receiver operating characteristic (ROC) and jack-knife free response operating characteristic (AFROC) values were established for each RAP. Specific features that had significant impact on accuracy were identified using Student's-T and Mann Whitney tests.</p></div><div><h3>Results</h3><p>RAPs with more than 10 years' experience in image interpretation, compared to those with less than 10 years’ experience, demonstrated lower specificity (51.3% vs 84.8%, p = 0.0264), ROC (0.83 vs 0.91, p = 0.0264) and AFROC (0.75 vs 0.87, p = 0.0037) values. Further, higher sensitivity values of 90.7% were seen in those RAPs who had an eye test in the last year compared to those who had not, 82% (p = 0.021). Other changes are presented in the paper.</p></div><div><h3>Conclusion</h3><p>These data reveal previously unidentified factors that impact the diagnostic efficacy of RAPs when interpreting mammographic images. Highlighting such findings will empower screening authorities to better examine ways of standardising performance and offer a baseline for performance benchmarks.</p></div><div><h3>Implications for practice</h3><p>This study for the first time performs an initial exploration of the factors that may be associated with RAP performance when interpreting screening mammograms.</p></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1078817424002189/pdfft?md5=3716c31510179ed96650a25bd34a6db5&pid=1-s2.0-S1078817424002189-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817424002189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
In the United Kingdom, radiographers with a qualification in image interpretation have interpreted mammograms since 1995. These radiographers work under the title of radiography advanced practitioners (RAP) or Consultant Radiographer. This study extends upon what has been very recently published by exploring further clinical, non-clinical and experiential factors that may impact the reporting performance of RAPs.
Methods
Fifteen RAPs interpreted an image test set of 60 2D mammograms of known truth using the Detected-X software platform. Unknown to the reader, twenty cases contained a malignancy. Sensitivity, specificity, lesion sensitivity, receiver operating characteristic (ROC) and jack-knife free response operating characteristic (AFROC) values were established for each RAP. Specific features that had significant impact on accuracy were identified using Student's-T and Mann Whitney tests.
Results
RAPs with more than 10 years' experience in image interpretation, compared to those with less than 10 years’ experience, demonstrated lower specificity (51.3% vs 84.8%, p = 0.0264), ROC (0.83 vs 0.91, p = 0.0264) and AFROC (0.75 vs 0.87, p = 0.0037) values. Further, higher sensitivity values of 90.7% were seen in those RAPs who had an eye test in the last year compared to those who had not, 82% (p = 0.021). Other changes are presented in the paper.
Conclusion
These data reveal previously unidentified factors that impact the diagnostic efficacy of RAPs when interpreting mammographic images. Highlighting such findings will empower screening authorities to better examine ways of standardising performance and offer a baseline for performance benchmarks.
Implications for practice
This study for the first time performs an initial exploration of the factors that may be associated with RAP performance when interpreting screening mammograms.
RadiographyRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍:
Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.