Numerical simulation and analysis of fatigue performance for the humeral stem

IF 3.3 2区 医学 Q2 ENGINEERING, BIOMEDICAL Journal of the Mechanical Behavior of Biomedical Materials Pub Date : 2024-09-11 DOI:10.1016/j.jmbbm.2024.106738
Haitao Xie , Haiqiong Xie , Wei Chen , Jinghua Zeng , Xu Tao , Hao Li
{"title":"Numerical simulation and analysis of fatigue performance for the humeral stem","authors":"Haitao Xie ,&nbsp;Haiqiong Xie ,&nbsp;Wei Chen ,&nbsp;Jinghua Zeng ,&nbsp;Xu Tao ,&nbsp;Hao Li","doi":"10.1016/j.jmbbm.2024.106738","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and objective</h3><p>Fatigue failure of the humeral stem is a severe long-term failure after shoulder arthroplasty, causing harm to patients and resulting in complex revision surgeries. However, there are few studies on humeral stem fatigue testing, and corresponding testing standards have not been established. Therefore, this study aims to investigate the fatigue performance of the humeral stem by establishing an efficient numerical simulation method.</p></div><div><h3>Methods</h3><p>Material properties are obtained by uniaxial tensile and fatigue tests. A parameterized static analysis program was written, and an automated fatigue numerical simulation platform was established using Abaqus, Fe-safe, and Isight in combination, enabling the establishment of a numerical simulation method for the fatigue performance of the humeral stem.</p></div><div><h3>Result</h3><p>Standard testing conditions include an 8 mm diameter humeral stem, a 40-21B humeral head, an 8° tilt angle, and a 2 mm fillet radius. Further research found that the fatigue life of the humeral stem decreases with increasing patient weight, and patients should control their weight after surgery.</p></div><div><h3>Conclusions</h3><p>The established automated fatigue numerical simulation platform avoids repetitive operations and efficiently completes large-scale calculations, guiding preoperative humeral stem selection and testing.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"160 ","pages":"Article 106738"},"PeriodicalIF":3.3000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124003709","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective

Fatigue failure of the humeral stem is a severe long-term failure after shoulder arthroplasty, causing harm to patients and resulting in complex revision surgeries. However, there are few studies on humeral stem fatigue testing, and corresponding testing standards have not been established. Therefore, this study aims to investigate the fatigue performance of the humeral stem by establishing an efficient numerical simulation method.

Methods

Material properties are obtained by uniaxial tensile and fatigue tests. A parameterized static analysis program was written, and an automated fatigue numerical simulation platform was established using Abaqus, Fe-safe, and Isight in combination, enabling the establishment of a numerical simulation method for the fatigue performance of the humeral stem.

Result

Standard testing conditions include an 8 mm diameter humeral stem, a 40-21B humeral head, an 8° tilt angle, and a 2 mm fillet radius. Further research found that the fatigue life of the humeral stem decreases with increasing patient weight, and patients should control their weight after surgery.

Conclusions

The established automated fatigue numerical simulation platform avoids repetitive operations and efficiently completes large-scale calculations, guiding preoperative humeral stem selection and testing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肱骨柄疲劳性能的数值模拟和分析
背景和目的肱骨柄的疲劳失效是肩关节置换术后的一种严重的长期失效,对患者造成伤害,并导致复杂的翻修手术。然而,有关肱骨柄疲劳测试的研究很少,相应的测试标准也尚未建立。因此,本研究旨在通过建立一种高效的数值模拟方法来研究肱骨柄的疲劳性能。结果标准测试条件包括直径 8 mm 的肱骨柄、40-21B 的肱骨头、8° 倾角和 2 mm 圆角半径。进一步研究发现,肱骨柄的疲劳寿命会随着患者体重的增加而缩短,因此患者术后应控制体重。结论已建立的自动化疲劳数值模拟平台避免了重复操作,并能高效完成大规模计算,为肱骨柄的术前选择和测试提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
期刊最新文献
Macroscopic creep behavior of spheroids derived from mesenchymal stem cells under compression Sequential irradiation does not improve fatigue crack propagation resistance of human cortical bone at 15 kGy Editorial Board Improving the processability and mechanical strength of self-hardening robocasted hydroxyapatite scaffolds with silane coupling agents Plastic strain localization in Bouligand structures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1