Bi-level generator start-up sequence optimization model for power system restoration considering the DoS attack

IF 5 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC International Journal of Electrical Power & Energy Systems Pub Date : 2024-09-17 DOI:10.1016/j.ijepes.2024.110219
{"title":"Bi-level generator start-up sequence optimization model for power system restoration considering the DoS attack","authors":"","doi":"10.1016/j.ijepes.2024.110219","DOIUrl":null,"url":null,"abstract":"<div><p>The reasonable generator start-up sequence (GSUS) strategy is beneficial to increasing the energy capacity of power systems after a blackout. Since the decision-making strategies of power systems are highly dependent on the cyber system, the denial of service (DoS) attack, as the most common type of cyber attacks, may prevent the generators from being re-started at their desired time and degrade performance of the optimal GSUS strategy in the power system restoration process, which has not been studied in the existing methods. To fill this gap, a bi-level GSUS optimization strategy against the DoS attack is proposed in this work. First, the effects of the DoS attack on the power generation of generators are analyzed and quantified by the generation energy loss. Then, a bi-level optimization model for the GSUS is proposed considering the DoS attack, where the upper-level model, referred to as the attacker model, aims to maximize the energy loss to prolong the restoration of generators by optimizing the time instant of the attack, while the lower-level model, referred to as the defender model, aims to maximize the energy generation by adjusting the optimal GSUS strategy in the restoration process. Both the upper-level and lower-level models are reformulated as mixed-integer linear programing problems, which can be efficiently solved by commercial solvers. Finally, the IEEE 39-bus power system and an actual power system in China are employed to verify the effectiveness of the proposed model.</p></div>","PeriodicalId":50326,"journal":{"name":"International Journal of Electrical Power & Energy Systems","volume":null,"pages":null},"PeriodicalIF":5.0000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S014206152400440X/pdfft?md5=c0b38df21c45444b7d06cd01d44ee27f&pid=1-s2.0-S014206152400440X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Power & Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S014206152400440X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The reasonable generator start-up sequence (GSUS) strategy is beneficial to increasing the energy capacity of power systems after a blackout. Since the decision-making strategies of power systems are highly dependent on the cyber system, the denial of service (DoS) attack, as the most common type of cyber attacks, may prevent the generators from being re-started at their desired time and degrade performance of the optimal GSUS strategy in the power system restoration process, which has not been studied in the existing methods. To fill this gap, a bi-level GSUS optimization strategy against the DoS attack is proposed in this work. First, the effects of the DoS attack on the power generation of generators are analyzed and quantified by the generation energy loss. Then, a bi-level optimization model for the GSUS is proposed considering the DoS attack, where the upper-level model, referred to as the attacker model, aims to maximize the energy loss to prolong the restoration of generators by optimizing the time instant of the attack, while the lower-level model, referred to as the defender model, aims to maximize the energy generation by adjusting the optimal GSUS strategy in the restoration process. Both the upper-level and lower-level models are reformulated as mixed-integer linear programing problems, which can be efficiently solved by commercial solvers. Finally, the IEEE 39-bus power system and an actual power system in China are employed to verify the effectiveness of the proposed model.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑 DoS 攻击的电力系统恢复双级发电机启动顺序优化模型
合理的发电机启动顺序(GSUS)策略有利于在停电后提高电力系统的发电能力。由于电力系统的决策策略高度依赖于网络系统,拒绝服务(DoS)攻击作为最常见的网络攻击类型,可能会阻止发电机在所需时间重新启动,降低电力系统恢复过程中最优 GSUS 策略的性能,而现有方法尚未对此进行研究。为填补这一空白,本文提出了一种针对 DoS 攻击的双层 GSUS 优化策略。首先,分析了 DoS 攻击对发电机发电量的影响,并通过发电能量损失进行量化。然后,考虑到 DoS 攻击,提出了 GSUS 的双层优化模型,其中上层模型称为攻击方模型,旨在通过优化攻击的时间瞬时来最大化能量损失,以延长发电机的恢复时间;下层模型称为防御方模型,旨在通过调整恢复过程中的最优 GSUS 策略来最大化发电量。上层模型和下层模型都被重新表述为混合整数线性规划问题,可由商用求解器高效求解。最后,利用 IEEE 39 总线电力系统和中国实际电力系统验证了所提模型的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Electrical Power & Energy Systems
International Journal of Electrical Power & Energy Systems 工程技术-工程:电子与电气
CiteScore
12.10
自引率
17.30%
发文量
1022
审稿时长
51 days
期刊介绍: The journal covers theoretical developments in electrical power and energy systems and their applications. The coverage embraces: generation and network planning; reliability; long and short term operation; expert systems; neural networks; object oriented systems; system control centres; database and information systems; stock and parameter estimation; system security and adequacy; network theory, modelling and computation; small and large system dynamics; dynamic model identification; on-line control including load and switching control; protection; distribution systems; energy economics; impact of non-conventional systems; and man-machine interfaces. As well as original research papers, the journal publishes short contributions, book reviews and conference reports. All papers are peer-reviewed by at least two referees.
期刊最新文献
Adaptive fault nature identification and soft restart criterion for hybrid multiterminal UHVDCs Mode identification-based model-free adaptive predictive damping control method for power system with wind farm considering communication delays Modeling of small-signal stability margin constrained optimal power flow Dynamic electricity theft behavior analysis based on active learning and incremental learning in new power systems Battery energy storage systems providing dynamic containment frequency response service
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1