Patient-specific surrogate model to predict pelvic floor dynamics during vaginal delivery

IF 3.3 2区 医学 Q2 ENGINEERING, BIOMEDICAL Journal of the Mechanical Behavior of Biomedical Materials Pub Date : 2024-09-17 DOI:10.1016/j.jmbbm.2024.106736
{"title":"Patient-specific surrogate model to predict pelvic floor dynamics during vaginal delivery","authors":"","doi":"10.1016/j.jmbbm.2024.106736","DOIUrl":null,"url":null,"abstract":"<div><p>Childbirth is a challenging event that can lead to long-term consequences such as prolapse or incontinence. While computational models are widely used to mimic vaginal delivery, their integration into clinical practice is hindered by time constraints. The primary goal of this study is to introduce an artificial intelligence pipeline that leverages patient-specific surrogate modeling to predict pelvic floor injuries during vaginal delivery. A finite element-based machine learning approach was implemented to generate a dataset with information from finite element simulations. Thousands of childbirth simulations were conducted, varying the dimensions of the pelvic floor muscles and the mechanical properties used for their characterization. Additionally, a mesh morphing algorithm was developed to obtain patient-specific models. Machine learning models, specifically tree-based algorithms such as Random Forest (RF) and Extreme Gradient Boosting, as well as Artificial Neural Networks, were trained to predict the nodal coordinates of nodes within the pelvic floor, aiming to predict the muscle stretch during a critical interval. The results indicate that the RF model performs best, with a mean absolute error (MAE) of 0.086 mm and a mean absolute percentage error of 0.38%. Overall, more than 80% of the nodes have an error smaller than 0.1 mm. The MAE for the calculated stretch is equal to 0.0011. The implemented pipeline allows loading the trained model and making predictions in less than 11 s. This work demonstrates the feasibility of implementing a machine learning framework in clinical practice to predict potential maternal injuries and assist in medical-decision making.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1751616124003680/pdfft?md5=18db24375ec240fe21dbc2ce80d7caa1&pid=1-s2.0-S1751616124003680-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124003680","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Childbirth is a challenging event that can lead to long-term consequences such as prolapse or incontinence. While computational models are widely used to mimic vaginal delivery, their integration into clinical practice is hindered by time constraints. The primary goal of this study is to introduce an artificial intelligence pipeline that leverages patient-specific surrogate modeling to predict pelvic floor injuries during vaginal delivery. A finite element-based machine learning approach was implemented to generate a dataset with information from finite element simulations. Thousands of childbirth simulations were conducted, varying the dimensions of the pelvic floor muscles and the mechanical properties used for their characterization. Additionally, a mesh morphing algorithm was developed to obtain patient-specific models. Machine learning models, specifically tree-based algorithms such as Random Forest (RF) and Extreme Gradient Boosting, as well as Artificial Neural Networks, were trained to predict the nodal coordinates of nodes within the pelvic floor, aiming to predict the muscle stretch during a critical interval. The results indicate that the RF model performs best, with a mean absolute error (MAE) of 0.086 mm and a mean absolute percentage error of 0.38%. Overall, more than 80% of the nodes have an error smaller than 0.1 mm. The MAE for the calculated stretch is equal to 0.0011. The implemented pipeline allows loading the trained model and making predictions in less than 11 s. This work demonstrates the feasibility of implementing a machine learning framework in clinical practice to predict potential maternal injuries and assist in medical-decision making.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
期刊最新文献
Patient-specific surrogate model to predict pelvic floor dynamics during vaginal delivery Promotion effect of proanthocyanidin on dentin remineralization via the polymer induced liquid precursor process The mechanical properties of chimeric silk are improved by expressing the full-length Trichonephila clavipes major ampullate spidroin gene in the silkworm Bombyx mori via recombinant AcMNPV Biological tissue for transcatheter aortic valve: The effect of crimping on fatigue strength Mechanical investigation of a Tandem embolization-visualization system for minimally invasive procedures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1