{"title":"Selective apigenin assay in plant extracts and herbal supplement with molecularly imprinted polymer-based electrochemical sensor","authors":"","doi":"10.1016/j.talanta.2024.126895","DOIUrl":null,"url":null,"abstract":"<div><p>This study is the first successful application of a nanomaterial-supported molecularly imprinted polymer (MIP)-based electrochemical sensor for the sensitive and selective determination of apigenin (API), which is a naturally occurring product of the flavone class that is an aglycone of several glycosides. Secondary metabolites are biologically active substances produced by plants in response to various environmental factors. The levels of these compounds can vary depending on factors such as climate, soil conditions and the season in which the plants are grown. Therefore, the analysis of these compounds is essential to properly understand the biological effects of plant extracts and to ensure their safe use. To increase the glassy carbon electrode (GCE) surface's active surface area and porosity, zinc oxide nanoparticles (ZnO NPs) were integrated into the MIP-based electrochemical sensor design. Tryptophan methacrylate (TrpMA) was selected as the functional monomer along with other MIP components such as 2-hydroxyethyl methacrylate (HEMA, basic monomer), 2-hydroxy-2-methylpropiophenone (initiator), and ethylene glycol dimethacrylate (EGDMA, crosslinking agent). The morphological and electrochemical characterizations of the developed API/ZnO NPs/TrpMA@MIP-GCE sensor were performed with scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The indirect measurement approach via 5.0 mM [Fe(CN)<sub>6</sub>]<sup>3–/4–</sup> solution was utilized to determine API in the linear range of 1.0x10<sup>−13</sup> M − 1.0x10<sup>−12</sup> M. The limit of detection (LOD) and limit of quantification (LOQ) for standard solutions were found to be 2.47x10<sup>−14</sup> and 8.23x10<sup>−14</sup> M, respectively. In addition, the extraction processes were carried out using ultrasound-assisted extraction (UAE) and maceration (MCR) procedures. For <em>Apium graveolens</em> L., <em>Petroselinum crispum</em> (Mill.) Fuss and herbal supplement, the API recoveries varied from 98.79 % to 102.71 %, with average relative standard deviations (RSD) less than 2.25 % in all three cases. The sensor's successful performance in the presence of components with chemical structures similar to the API was also demonstrated, revealing its unique selectivity.</p></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":null,"pages":null},"PeriodicalIF":5.6000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914024012748","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
This study is the first successful application of a nanomaterial-supported molecularly imprinted polymer (MIP)-based electrochemical sensor for the sensitive and selective determination of apigenin (API), which is a naturally occurring product of the flavone class that is an aglycone of several glycosides. Secondary metabolites are biologically active substances produced by plants in response to various environmental factors. The levels of these compounds can vary depending on factors such as climate, soil conditions and the season in which the plants are grown. Therefore, the analysis of these compounds is essential to properly understand the biological effects of plant extracts and to ensure their safe use. To increase the glassy carbon electrode (GCE) surface's active surface area and porosity, zinc oxide nanoparticles (ZnO NPs) were integrated into the MIP-based electrochemical sensor design. Tryptophan methacrylate (TrpMA) was selected as the functional monomer along with other MIP components such as 2-hydroxyethyl methacrylate (HEMA, basic monomer), 2-hydroxy-2-methylpropiophenone (initiator), and ethylene glycol dimethacrylate (EGDMA, crosslinking agent). The morphological and electrochemical characterizations of the developed API/ZnO NPs/TrpMA@MIP-GCE sensor were performed with scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The indirect measurement approach via 5.0 mM [Fe(CN)6]3–/4– solution was utilized to determine API in the linear range of 1.0x10−13 M − 1.0x10−12 M. The limit of detection (LOD) and limit of quantification (LOQ) for standard solutions were found to be 2.47x10−14 and 8.23x10−14 M, respectively. In addition, the extraction processes were carried out using ultrasound-assisted extraction (UAE) and maceration (MCR) procedures. For Apium graveolens L., Petroselinum crispum (Mill.) Fuss and herbal supplement, the API recoveries varied from 98.79 % to 102.71 %, with average relative standard deviations (RSD) less than 2.25 % in all three cases. The sensor's successful performance in the presence of components with chemical structures similar to the API was also demonstrated, revealing its unique selectivity.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.