Assessment on the Personal Exposure Risk Associated With Real-Time Indoor PM2.5 in Different Microenvironments

IF 4.3 2区 环境科学与生态学 Q1 CONSTRUCTION & BUILDING TECHNOLOGY Indoor air Pub Date : 2024-09-17 DOI:10.1155/2024/2236778
Shuiping Dai, Yuhang He, Ni Zeng, Zhenglu Wang
{"title":"Assessment on the Personal Exposure Risk Associated With Real-Time Indoor PM2.5 in Different Microenvironments","authors":"Shuiping Dai,&nbsp;Yuhang He,&nbsp;Ni Zeng,&nbsp;Zhenglu Wang","doi":"10.1155/2024/2236778","DOIUrl":null,"url":null,"abstract":"<p>The cytotoxicity of PM<sub>2.5</sub> (fine particulate) derived from varying fuels burning in different microenvironments remains unclear. In this study, the toxicity of PM<sub>2.5</sub> collected from northern China in the winter on human cervical carcinoma (HeLa) cells was determined. The PM<sub>2.5</sub> from chunk coal (CC) combustion caused greater apoptosis (22.47%) than firewood (FW) burning (5.32%), while the effects on cell viability showed contrary patterns between FW (stimulation: 132.38%) and CC (inhibition: 87.05%). Furthermore, all the samples induced significant oxidative stress and inflammatory responses in cells. Intriguingly, PM<sub>2.5</sub> samples collected from FW burning upregulated the expression genes involved in pathways in cancer, whereas those from CC burning downregulated the levels. Accordingly, the health risks of different samples were assessed through a probabilistic model. The risk level of samples of CC burning from the living room (CC/L) was 0.752, followed by CC from the bedroom (CC/B, 0.736), and then CC from the kitchen (CC/K, 0.562), FW without a chimney (FW-C, 0.451), and FW with a chimney (FW+C, 0.446). Meanwhile, the survival curves established by gene expression indicated that PM<sub>2.5</sub> from FW might be positively correlated with cancer progression. This pilot investigation demonstrated that CC combustion in the living room posed the highest health risk, and improved cookstoves (with a chimney) markedly reduced the risk. This pilot study presents a novel model for assessing health risks associated with air pollution using the toxicology method and real-time PM<sub>2.5</sub> quantification.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/2236778","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/2236778","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The cytotoxicity of PM2.5 (fine particulate) derived from varying fuels burning in different microenvironments remains unclear. In this study, the toxicity of PM2.5 collected from northern China in the winter on human cervical carcinoma (HeLa) cells was determined. The PM2.5 from chunk coal (CC) combustion caused greater apoptosis (22.47%) than firewood (FW) burning (5.32%), while the effects on cell viability showed contrary patterns between FW (stimulation: 132.38%) and CC (inhibition: 87.05%). Furthermore, all the samples induced significant oxidative stress and inflammatory responses in cells. Intriguingly, PM2.5 samples collected from FW burning upregulated the expression genes involved in pathways in cancer, whereas those from CC burning downregulated the levels. Accordingly, the health risks of different samples were assessed through a probabilistic model. The risk level of samples of CC burning from the living room (CC/L) was 0.752, followed by CC from the bedroom (CC/B, 0.736), and then CC from the kitchen (CC/K, 0.562), FW without a chimney (FW-C, 0.451), and FW with a chimney (FW+C, 0.446). Meanwhile, the survival curves established by gene expression indicated that PM2.5 from FW might be positively correlated with cancer progression. This pilot investigation demonstrated that CC combustion in the living room posed the highest health risk, and improved cookstoves (with a chimney) markedly reduced the risk. This pilot study presents a novel model for assessing health risks associated with air pollution using the toxicology method and real-time PM2.5 quantification.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor air
Indoor air 环境科学-工程:环境
CiteScore
10.80
自引率
10.30%
发文量
175
审稿时长
3 months
期刊介绍: The quality of the environment within buildings is a topic of major importance for public health. Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques. The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.
期刊最新文献
Assessment on the Personal Exposure Risk Associated With Real-Time Indoor PM2.5 in Different Microenvironments Shared Risk Volatile Organic Compounds Among Chronic Respiratory Diseases: Mediation Effects of System Inflammation Comparison of Real-Time PM2.5 Between Rural and Urban Homes in Southwest China Based on Field Measurement: Insight Into the Cooking Activity Contribution Investigation of Indoor Airborne Bacteria in the Severe Cold Region in China: Genera, Levels, and the Influencing Factors of Concentration Patterns of Resident Activity and Their Impact on Environmental Parameters in Residential Apartments: Case Study and Implications for Design and Management
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1