Improved Teflon lift-off for droplet microarray generation and single-cell separation on digital microfluidic chips†

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS Lab on a Chip Pub Date : 2024-09-18 DOI:10.1039/D4LC00630E
Chuanjie Shen, Zhaoduo Tong, Xin Xu and Hongju Mao
{"title":"Improved Teflon lift-off for droplet microarray generation and single-cell separation on digital microfluidic chips†","authors":"Chuanjie Shen, Zhaoduo Tong, Xin Xu and Hongju Mao","doi":"10.1039/D4LC00630E","DOIUrl":null,"url":null,"abstract":"<p >Droplet microarrays (DMAs) leveraging wettability differences are instrumental in digital immunoassays, single-cell analysis, and high-throughput screening. This study introduces an enhanced Teflon lift-off process to fabricate hydrophilic–hydrophobic patterns on a digital microfluidic (DMF) chip, thereby integrating DMAs with DMF technology. By employing DMF for droplet manipulation and utilizing wettability differences, the automated generation of high-throughput DMAs was achieved. The volume of the microdroplets ranged from picoliters to nanoliters. For droplets with a diameter of 150 μm, the array density reached up to 1282 cm<small><sup>−2</sup></small>. We systematically investigated the influence of various DMF parameters on the formation of DMAs and applied this technique to particle distribution, achieving a single-cell isolation rate of approximately 30%. We believe that this method will be a potent tool to enhance the capabilities of DMAs and DMF technology and extend their applicability across more fields.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":null,"pages":null},"PeriodicalIF":6.1000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/lc/d4lc00630e","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Droplet microarrays (DMAs) leveraging wettability differences are instrumental in digital immunoassays, single-cell analysis, and high-throughput screening. This study introduces an enhanced Teflon lift-off process to fabricate hydrophilic–hydrophobic patterns on a digital microfluidic (DMF) chip, thereby integrating DMAs with DMF technology. By employing DMF for droplet manipulation and utilizing wettability differences, the automated generation of high-throughput DMAs was achieved. The volume of the microdroplets ranged from picoliters to nanoliters. For droplets with a diameter of 150 μm, the array density reached up to 1282 cm−2. We systematically investigated the influence of various DMF parameters on the formation of DMAs and applied this technique to particle distribution, achieving a single-cell isolation rate of approximately 30%. We believe that this method will be a potent tool to enhance the capabilities of DMAs and DMF technology and extend their applicability across more fields.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
数字微流控芯片上用于液滴微阵列生成和单细胞分离的改良型特氟龙掀起器
利用润湿性差异的液滴微阵列(DMAs)在数字免疫分析、单细胞分析和高通量筛选中发挥着重要作用。本研究介绍了一种增强型特氟龙掀离工艺,用于在数字微流控(DMF)芯片上制作亲水-疏水图案,从而将 DMA 与 DMF 技术相结合。通过使用 DMF 进行液滴操作并利用润湿性差异,实现了高干旱 DMA 的自动生成。微液滴的体积从皮升到纳升不等。对于直径为 150 μm 的液滴,阵列密度高达 1282/cm2。我们系统地研究了各种 DMF 参数对 DMA 形成的影响,并将该技术应用于粒子分布,实现了约 30% 的单细胞分离率。我们相信,这种方法将成为提高 DMAs 和 DMF 技术能力的有力工具,并将其应用扩展到更多领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Observing root growth and signalling responses to stress gradients and pathogens using the bi-directional dual-flow RootChip Optical tweezer-assisted cell pairing and fusion for somatic cell nuclear transfer within an open microchannel. Microstring-engineered tension tissues: A novel platform for replicating tissue mechanics and advancing mechanobiology Discretised microfluidics for noninvasive health monitoring using sweat sensing Inside back cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1