{"title":"Investigating Radon Concentrations in the Cango Cave, South Africa","authors":"Jacques Bezuidenhout, Rikus le Roux","doi":"10.3390/atmos15091133","DOIUrl":null,"url":null,"abstract":"Radon concentrations in the tourist part of the Cango cave were measured using 25 strategically placed electret ion chambers. Airflow rates were also measured and found to be less than 1 m/s throughout the cave. An IDW interpolated radon concentration overlay was constructed using QGIS and overlayed on maps of the cave. The maximum radon concentration of 2625 Bq/m3 was measured in the Grand Hall, located in the central part of the cave following a narrow passage. The initial part of the cave near the entrance exhibited normal cave breathing characteristics, with radon concentrations of less than 300 Bq/m3. The deepest section of the cave, however, demonstrated an unexpected decrease in radon levels, temperature, and humidity. The average radon concentration in the Cango cave, measured at 1265 Bq/m3, is relatively low compared to other caves worldwide that need mitigation measures according to the International Commission on Radiological Protection (ICRP).","PeriodicalId":8580,"journal":{"name":"Atmosphere","volume":"13 1","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmosphere","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.3390/atmos15091133","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Radon concentrations in the tourist part of the Cango cave were measured using 25 strategically placed electret ion chambers. Airflow rates were also measured and found to be less than 1 m/s throughout the cave. An IDW interpolated radon concentration overlay was constructed using QGIS and overlayed on maps of the cave. The maximum radon concentration of 2625 Bq/m3 was measured in the Grand Hall, located in the central part of the cave following a narrow passage. The initial part of the cave near the entrance exhibited normal cave breathing characteristics, with radon concentrations of less than 300 Bq/m3. The deepest section of the cave, however, demonstrated an unexpected decrease in radon levels, temperature, and humidity. The average radon concentration in the Cango cave, measured at 1265 Bq/m3, is relatively low compared to other caves worldwide that need mitigation measures according to the International Commission on Radiological Protection (ICRP).
期刊介绍:
Atmosphere (ISSN 2073-4433) is an international and cross-disciplinary scholarly journal of scientific studies related to the atmosphere. It publishes reviews, regular research papers, communications and short notes, and there is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodical details must be provided for research articles.