{"title":"Robust unsupervised texture segmentation for motion analysis in ultrasound images","authors":"Arnaud Brignol, Farida Cheriet, Jean-François Aubin-Fournier, Carole Fortin, Catherine Laporte","doi":"10.1007/s11548-024-03249-1","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>Ultrasound imaging has emerged as a promising cost-effective and portable non-irradiant modality for the diagnosis and follow-up of diseases. Motion analysis can be performed by segmenting anatomical structures of interest before tracking them over time. However, doing so in a robust way is challenging as ultrasound images often display a low contrast and blurry boundaries.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>In this paper, a robust descriptor inspired from the fractal dimension is presented to locally characterize the gray-level variations of an image. This descriptor is an adaptive grid pattern whose scale locally varies as the gray-level variations of the image. Robust features are then located based on the gray-level variations, which are more likely to be consistently tracked over time despite the presence of noise.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The method was validated on three datasets: segmentation of the left ventricle on simulated echocardiography (Dice coefficient, DC), accuracy of diaphragm motion tracking for healthy subjects (mean sum of distances, MSD) and for a scoliosis patient (root mean square error, RMSE). Results show that the method segments the left ventricle accurately (<span>\\(\\textrm{DC}=0.84\\)</span>) and robustly tracks the diaphragm motion for healthy subjects (<span>\\(\\textrm{MSD}=1.10\\)</span> mm) and for the scoliosis patient (<span>\\(\\textrm{RMSE}=1.22\\)</span> mm).</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>This method has the potential to segment structures of interest according to their texture in an unsupervised fashion, as well as to help analyze the deformation of tissues. Possible applications are not limited to US image. The same principle could also be applied to other medical imaging modalities such as MRI or CT scans.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":"3 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03249-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
Ultrasound imaging has emerged as a promising cost-effective and portable non-irradiant modality for the diagnosis and follow-up of diseases. Motion analysis can be performed by segmenting anatomical structures of interest before tracking them over time. However, doing so in a robust way is challenging as ultrasound images often display a low contrast and blurry boundaries.
Methods
In this paper, a robust descriptor inspired from the fractal dimension is presented to locally characterize the gray-level variations of an image. This descriptor is an adaptive grid pattern whose scale locally varies as the gray-level variations of the image. Robust features are then located based on the gray-level variations, which are more likely to be consistently tracked over time despite the presence of noise.
Results
The method was validated on three datasets: segmentation of the left ventricle on simulated echocardiography (Dice coefficient, DC), accuracy of diaphragm motion tracking for healthy subjects (mean sum of distances, MSD) and for a scoliosis patient (root mean square error, RMSE). Results show that the method segments the left ventricle accurately (\(\textrm{DC}=0.84\)) and robustly tracks the diaphragm motion for healthy subjects (\(\textrm{MSD}=1.10\) mm) and for the scoliosis patient (\(\textrm{RMSE}=1.22\) mm).
Conclusions
This method has the potential to segment structures of interest according to their texture in an unsupervised fashion, as well as to help analyze the deformation of tissues. Possible applications are not limited to US image. The same principle could also be applied to other medical imaging modalities such as MRI or CT scans.
期刊介绍:
The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.