Robust unsupervised texture segmentation for motion analysis in ultrasound images

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal of Computer Assisted Radiology and Surgery Pub Date : 2024-09-17 DOI:10.1007/s11548-024-03249-1
Arnaud Brignol, Farida Cheriet, Jean-François Aubin-Fournier, Carole Fortin, Catherine Laporte
{"title":"Robust unsupervised texture segmentation for motion analysis in ultrasound images","authors":"Arnaud Brignol, Farida Cheriet, Jean-François Aubin-Fournier, Carole Fortin, Catherine Laporte","doi":"10.1007/s11548-024-03249-1","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>Ultrasound imaging has emerged as a promising cost-effective and portable non-irradiant modality for the diagnosis and follow-up of diseases. Motion analysis can be performed by segmenting anatomical structures of interest before tracking them over time. However, doing so in a robust way is challenging as ultrasound images often display a low contrast and blurry boundaries.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>In this paper, a robust descriptor inspired from the fractal dimension is presented to locally characterize the gray-level variations of an image. This descriptor is an adaptive grid pattern whose scale locally varies as the gray-level variations of the image. Robust features are then located based on the gray-level variations, which are more likely to be consistently tracked over time despite the presence of noise.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The method was validated on three datasets: segmentation of the left ventricle on simulated echocardiography (Dice coefficient, DC), accuracy of diaphragm motion tracking for healthy subjects (mean sum of distances, MSD) and for a scoliosis patient (root mean square error, RMSE). Results show that the method segments the left ventricle accurately (<span>\\(\\textrm{DC}=0.84\\)</span>) and robustly tracks the diaphragm motion for healthy subjects (<span>\\(\\textrm{MSD}=1.10\\)</span> mm) and for the scoliosis patient (<span>\\(\\textrm{RMSE}=1.22\\)</span> mm).</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>This method has the potential to segment structures of interest according to their texture in an unsupervised fashion, as well as to help analyze the deformation of tissues. Possible applications are not limited to US image. The same principle could also be applied to other medical imaging modalities such as MRI or CT scans.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":"3 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03249-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Ultrasound imaging has emerged as a promising cost-effective and portable non-irradiant modality for the diagnosis and follow-up of diseases. Motion analysis can be performed by segmenting anatomical structures of interest before tracking them over time. However, doing so in a robust way is challenging as ultrasound images often display a low contrast and blurry boundaries.

Methods

In this paper, a robust descriptor inspired from the fractal dimension is presented to locally characterize the gray-level variations of an image. This descriptor is an adaptive grid pattern whose scale locally varies as the gray-level variations of the image. Robust features are then located based on the gray-level variations, which are more likely to be consistently tracked over time despite the presence of noise.

Results

The method was validated on three datasets: segmentation of the left ventricle on simulated echocardiography (Dice coefficient, DC), accuracy of diaphragm motion tracking for healthy subjects (mean sum of distances, MSD) and for a scoliosis patient (root mean square error, RMSE). Results show that the method segments the left ventricle accurately (\(\textrm{DC}=0.84\)) and robustly tracks the diaphragm motion for healthy subjects (\(\textrm{MSD}=1.10\) mm) and for the scoliosis patient (\(\textrm{RMSE}=1.22\) mm).

Conclusions

This method has the potential to segment structures of interest according to their texture in an unsupervised fashion, as well as to help analyze the deformation of tissues. Possible applications are not limited to US image. The same principle could also be applied to other medical imaging modalities such as MRI or CT scans.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于超声图像运动分析的鲁棒无监督纹理分割技术
目的 超声波成像已成为诊断和跟踪疾病的一种具有成本效益的便携式非辐射模式。运动分析可通过对感兴趣的解剖结构进行分割,然后再对其进行时间跟踪。然而,由于超声波图像通常对比度低、边界模糊,因此要以稳健的方式进行运动分析极具挑战性。本文提出了一种受分形维度启发的稳健描述符,用于局部描述图像的灰度变化。该描述符是一种自适应网格模式,其尺度随图像灰度变化而局部变化。结果该方法在三个数据集上进行了验证:模拟超声心动图左心室的分割(Dice系数,DC)、健康受试者膈肌运动跟踪的准确性(平均距离总和,MSD)和脊柱侧弯患者的准确性(均方根误差,RMSE)。结果表明,该方法能准确地分割左心室(\(\textrm{DC}=0.84\)),并能稳健地跟踪健康受试者的膈肌运动(\(\textrm{MSD}=1.10\)mm)和脊柱侧弯患者的膈肌运动(\(\textrm{RMSE}=1.22\)mm)。结论这种方法可以根据纹理以无监督的方式分割感兴趣的结构,并帮助分析组织的变形。该方法的应用范围不仅限于 US 图像。同样的原理也可应用于其他医学成像模式,如核磁共振成像或 CT 扫描。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
期刊最新文献
Avoiding missed opportunities in AI for radiology. Hybrid registration of the fibula for electromagnetically navigated osteotomies in mandibular reconstructive surgery: a phantom study. Validity of a virtual reality-based straight coloanal anastomosis simulator. Computational fluid dynamics and shape analysis enhance aneurysm rupture risk stratification. MINARO DRS: usability study of a robotic-assisted laminectomy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1