Power Oscillation Damping Controllers for Grid-Forming Power Converters in Modern PowerSystems

Elia Mateu-Barriendos, Onur Alican, Javier Renedo, Carlos Collados-Rodriguez, Macarena Martin, Edgar Nuño, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt
{"title":"Power Oscillation Damping Controllers for Grid-Forming Power Converters in Modern PowerSystems","authors":"Elia Mateu-Barriendos, Onur Alican, Javier Renedo, Carlos Collados-Rodriguez, Macarena Martin, Edgar Nuño, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt","doi":"arxiv-2409.10726","DOIUrl":null,"url":null,"abstract":"Inter-area oscillations have been extensively studied in conventional power\nsystems dominated by synchronous machines, as well as methods to mitigate them.\nSeveral publications have addressed Power Oscillation Damping (POD) controllers\nin grid-following voltage source converters (GFOL). However, the performance of\nPOD controllers for Grid-Forming voltage source converters (GFOR) in modern\npower systems with increased penetration of power electronics requires further\ninvestigation. This paper investigates the performance of GFORs and\nsupplementary POD controllers in the damping of electromechanical oscillations\nin modern power systems. This paper proposes POD controllers in GFORs by\nsupplementary modulation of active- and reactive-power injections of the\nconverter and both simultaneously (POD- P, POD-Q and POD-PQ, respectively). The\nproposed POD controllers use the frequency imposed by the GFOR as the input\nsignal, which has a simple implementation and it eliminates the need for\nadditional measurements. Eigenvalue-sensitivity methods using a synthetic test\nsystem are applied to the design of POD controllers in GFORs, which is useful\nwhen limited information of the power system is available. This paper\ndemonstrates the effectiveness of POD controllers in GFOR converters to damp\nelectromechanical oscillations, by small-signal stability analysis and\nnon-linear time-domain simulations in a small test system and in a large-scale\npower system.","PeriodicalId":501175,"journal":{"name":"arXiv - EE - Systems and Control","volume":"7 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - EE - Systems and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2409.10726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Inter-area oscillations have been extensively studied in conventional power systems dominated by synchronous machines, as well as methods to mitigate them. Several publications have addressed Power Oscillation Damping (POD) controllers in grid-following voltage source converters (GFOL). However, the performance of POD controllers for Grid-Forming voltage source converters (GFOR) in modern power systems with increased penetration of power electronics requires further investigation. This paper investigates the performance of GFORs and supplementary POD controllers in the damping of electromechanical oscillations in modern power systems. This paper proposes POD controllers in GFORs by supplementary modulation of active- and reactive-power injections of the converter and both simultaneously (POD- P, POD-Q and POD-PQ, respectively). The proposed POD controllers use the frequency imposed by the GFOR as the input signal, which has a simple implementation and it eliminates the need for additional measurements. Eigenvalue-sensitivity methods using a synthetic test system are applied to the design of POD controllers in GFORs, which is useful when limited information of the power system is available. This paper demonstrates the effectiveness of POD controllers in GFOR converters to damp electromechanical oscillations, by small-signal stability analysis and non-linear time-domain simulations in a small test system and in a large-scale power system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
现代电力系统中并网型电力转换器的功率振荡阻尼控制器
在以同步电机为主导的传统电力系统中,人们已经广泛研究了区域间振荡以及缓解振荡的方法。然而,在电力电子技术渗透率不断提高的现代电力系统中,电网电压源变换器(GFOR)的功率振荡抑制(POD)控制器的性能还需要进一步研究。本文研究了现代电力系统中 GFOR 和辅助 POD 控制器在抑制机电振荡方面的性能。本文提出了 GFOR 中的 POD 控制器,即同时对变流器的有功功率注入和无功功率注入进行补充调制(分别为 POD-P、POD-Q 和 POD-PQ)。拟议的 POD 控制器使用 GFOR 施加的频率作为输入信号,实现简单,无需额外测量。使用合成测试系统的特征值灵敏度方法被应用于 GFOR 中 POD 控制器的设计,这在电力系统信息有限的情况下非常有用。本文通过在小型测试系统和大型电力系统中进行小信号稳定性分析和非线性时域仿真,证明了 POD 控制器在 GFOR 变流器中抑制机电振荡的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Data-Efficient Quadratic Q-Learning Using LMIs On the Stability of Consensus Control under Rotational Ambiguities System-Level Efficient Performance of EMLA-Driven Heavy-Duty Manipulators via Bilevel Optimization Framework with a Leader--Follower Scenario ReLU Surrogates in Mixed-Integer MPC for Irrigation Scheduling Model-Free Generic Robust Control for Servo-Driven Actuation Mechanisms with Experimental Verification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1