An acoustic bellows-type round window transducer for middle-ear implants

IF 1.4 3区 医学 Q4 ENGINEERING, BIOMEDICAL Clinical Biomechanics Pub Date : 2024-09-18 DOI:10.1016/j.clinbiomech.2024.106349
{"title":"An acoustic bellows-type round window transducer for middle-ear implants","authors":"","doi":"10.1016/j.clinbiomech.2024.106349","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>This study describes the development of output devices for round window middle-ear. To overcome the problems of output devices that apply sound pressure directly to the round window, an acoustic bellows-type round window transducer was implemented by combining a small bellows, acoustic tube, and balanced armature driver.</p></div><div><h3>Methods</h3><p>The output characteristics of the proposed acoustic bellows-type round window transducer were confirmed through bench tests and distortion measurements. To compare the vibration transmission characteristics of the proposed transducer with those of sound pressure stimulation devices, an experiment was performed using four human temporal bones.</p></div><div><h3>Findings</h3><p>The average output magnitude of the acoustic bellows-type round window transducer was equivalent to sound pressure levels of 92, 96, and 108 dB for frequency ranges of &lt;1, 1–2, and &gt; 2 kHz, respectively. The results showed that the proposed transducer delivered vibration consistently without reducing the sound pressure level due to leakage, unlike the sound pressure stimulation device.</p></div><div><h3>Interpretation</h3><p>Therefore, the acoustic bellows-type round window transducer is a more stable and suitable output device for round window middle-ear implants than a sound pressure stimulation device. It is expected to overcome the limitations of sound pressure stimulation devices and to contribute to new technical solutions in the field of round window middle-ear implants development.</p></div>","PeriodicalId":50992,"journal":{"name":"Clinical Biomechanics","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0268003324001815/pdfft?md5=814429f427855b445390e28b493e9f46&pid=1-s2.0-S0268003324001815-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0268003324001815","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background

This study describes the development of output devices for round window middle-ear. To overcome the problems of output devices that apply sound pressure directly to the round window, an acoustic bellows-type round window transducer was implemented by combining a small bellows, acoustic tube, and balanced armature driver.

Methods

The output characteristics of the proposed acoustic bellows-type round window transducer were confirmed through bench tests and distortion measurements. To compare the vibration transmission characteristics of the proposed transducer with those of sound pressure stimulation devices, an experiment was performed using four human temporal bones.

Findings

The average output magnitude of the acoustic bellows-type round window transducer was equivalent to sound pressure levels of 92, 96, and 108 dB for frequency ranges of <1, 1–2, and > 2 kHz, respectively. The results showed that the proposed transducer delivered vibration consistently without reducing the sound pressure level due to leakage, unlike the sound pressure stimulation device.

Interpretation

Therefore, the acoustic bellows-type round window transducer is a more stable and suitable output device for round window middle-ear implants than a sound pressure stimulation device. It is expected to overcome the limitations of sound pressure stimulation devices and to contribute to new technical solutions in the field of round window middle-ear implants development.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于中耳植入的波纹管型圆窗声学换能器
背景本研究介绍了圆窗中耳输出设备的开发情况。为了克服直接向圆窗施加声压的输出设备所存在的问题,研究人员将小波纹管、声学管和平衡电枢驱动器组合在一起,实现了声学波纹管式圆窗换能器。方法通过台架试验和失真测量确认了所提出的声学波纹管式圆窗换能器的输出特性。结果声学波纹管型圆窗换能器的平均输出幅度在频率范围为 1、1-2 和 2 kHz 时分别相当于 92、96 和 108 dB 的声压级。因此,与声压刺激装置相比,声学波纹管型圆窗换能器是一种更稳定、更适用于圆窗中耳植入的输出装置。它有望克服声压刺激装置的局限性,并为圆窗中耳植入物开发领域提供新的技术解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Biomechanics
Clinical Biomechanics 医学-工程:生物医学
CiteScore
3.30
自引率
5.60%
发文量
189
审稿时长
12.3 weeks
期刊介绍: Clinical Biomechanics is an international multidisciplinary journal of biomechanics with a focus on medical and clinical applications of new knowledge in the field. The science of biomechanics helps explain the causes of cell, tissue, organ and body system disorders, and supports clinicians in the diagnosis, prognosis and evaluation of treatment methods and technologies. Clinical Biomechanics aims to strengthen the links between laboratory and clinic by publishing cutting-edge biomechanics research which helps to explain the causes of injury and disease, and which provides evidence contributing to improved clinical management. A rigorous peer review system is employed and every attempt is made to process and publish top-quality papers promptly. Clinical Biomechanics explores all facets of body system, organ, tissue and cell biomechanics, with an emphasis on medical and clinical applications of the basic science aspects. The role of basic science is therefore recognized in a medical or clinical context. The readership of the journal closely reflects its multi-disciplinary contents, being a balance of scientists, engineers and clinicians. The contents are in the form of research papers, brief reports, review papers and correspondence, whilst special interest issues and supplements are published from time to time. Disciplines covered include biomechanics and mechanobiology at all scales, bioengineering and use of tissue engineering and biomaterials for clinical applications, biophysics, as well as biomechanical aspects of medical robotics, ergonomics, physical and occupational therapeutics and rehabilitation.
期刊最新文献
Mid-vastus approach induces milder short-term effects on postural control compared to parapatellar approach in total knee arthroplasty. Between-limb difference in peak knee flexion angle can identify persons post-stroke with Stiff-Knee gait Fall assessment in healthy older adults: Approach using rambling-trembling decomposition method Biomechanical analysis of the effect of postero-latero-central tibial plateau fractures in the knee joint: Can posterior soft tissues prevent instability? A finite element study. Biomechanical modelling of indirect decompression in oblique lumbar intervertebral fusions – A finite element study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1