Label-free single-cell antimicrobial susceptibility testing in droplets with concentration gradient generation

IF 6.1 2区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS Lab on a Chip Pub Date : 2024-09-20 DOI:10.1039/d4lc00629a
Jae Seong Kim, Jingyeong Kim, Jae-Seok Kim, Wooseong Kim, Chang-Soo Lee
{"title":"Label-free single-cell antimicrobial susceptibility testing in droplets with concentration gradient generation","authors":"Jae Seong Kim, Jingyeong Kim, Jae-Seok Kim, Wooseong Kim, Chang-Soo Lee","doi":"10.1039/d4lc00629a","DOIUrl":null,"url":null,"abstract":"Bacterial communities exhibit significant heterogeneity, resulting in the emergence of specialized phenotypes that can withstand antibiotic exposure. Unfortunately, the existence of subpopulations resistant to antibiotics often goes unnoticed during treatment initiation. Thus, it is crucial to consider the concept of single-cell antibiotic susceptibility testing (AST) to tackle bacterial infections. Nevertheless, its practical application in clinical settings is hindered by its inability to conduct AST efficiently across a wide range of antibiotics and concentrations. This study introduces a droplet-based microfluidic platform designed for rapid single-cell AST by creating an antibiotic concentration gradient. The advantage of a microfluidic platform is achieved by executing bacteria and antibiotic mixing, cell encapsulation, incubation, and enumeration of bacteria in a seamless workflow, facilitating susceptibility testing of each antibiotic. Firstly, we demonstrate the rapid determination of minimum inhibitory concentration (MIC) of several antibiotics with Gram-negative E. coli and Gram-negative S. aureus, which enables us to bypass the time-consuming bacteria cultivation, speeding up the AST in 3 hrs from 1 – 2 days of conventional methods. Additionally, we assess 10 clinical isolates including methicillin-resistant Staphylococcus aureus (MRSA) and multidrug-resistant Staphylococcus aureus (MDRSA) against clinically important antibiotics for analyzing MIC, compared to the gold standard AST method from the United States Clinical and Laboratory Standards Institute (CLSI), which becomes available only after 48 h. Furthermore, by monitoring single cells within individual droplets, we have found a spectrum of resistance levels among genetically identical cells, revealing phenotypic heterogeneity within isogenic populations. This discovery not only advances clinical diagnostics and treatment strategies but also significantly contributes to the field of antibiotic stewardship, underlining the importance of our approach in addressing bacterial resistance.","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":"19 1","pages":""},"PeriodicalIF":6.1000,"publicationDate":"2024-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d4lc00629a","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Bacterial communities exhibit significant heterogeneity, resulting in the emergence of specialized phenotypes that can withstand antibiotic exposure. Unfortunately, the existence of subpopulations resistant to antibiotics often goes unnoticed during treatment initiation. Thus, it is crucial to consider the concept of single-cell antibiotic susceptibility testing (AST) to tackle bacterial infections. Nevertheless, its practical application in clinical settings is hindered by its inability to conduct AST efficiently across a wide range of antibiotics and concentrations. This study introduces a droplet-based microfluidic platform designed for rapid single-cell AST by creating an antibiotic concentration gradient. The advantage of a microfluidic platform is achieved by executing bacteria and antibiotic mixing, cell encapsulation, incubation, and enumeration of bacteria in a seamless workflow, facilitating susceptibility testing of each antibiotic. Firstly, we demonstrate the rapid determination of minimum inhibitory concentration (MIC) of several antibiotics with Gram-negative E. coli and Gram-negative S. aureus, which enables us to bypass the time-consuming bacteria cultivation, speeding up the AST in 3 hrs from 1 – 2 days of conventional methods. Additionally, we assess 10 clinical isolates including methicillin-resistant Staphylococcus aureus (MRSA) and multidrug-resistant Staphylococcus aureus (MDRSA) against clinically important antibiotics for analyzing MIC, compared to the gold standard AST method from the United States Clinical and Laboratory Standards Institute (CLSI), which becomes available only after 48 h. Furthermore, by monitoring single cells within individual droplets, we have found a spectrum of resistance levels among genetically identical cells, revealing phenotypic heterogeneity within isogenic populations. This discovery not only advances clinical diagnostics and treatment strategies but also significantly contributes to the field of antibiotic stewardship, underlining the importance of our approach in addressing bacterial resistance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用浓度梯度生成技术在液滴中进行无标记单细胞抗菌药物敏感性测试
细菌群落表现出明显的异质性,从而产生了能够耐受抗生素暴露的特化表型。不幸的是,对抗生素具有耐药性的亚群的存在往往在开始治疗时被忽视。因此,考虑用单细胞抗生素药敏试验(AST)的概念来解决细菌感染问题至关重要。然而,单细胞抗生素药敏试验无法在多种抗生素和浓度下有效进行,这阻碍了它在临床环境中的实际应用。本研究介绍了一种基于液滴的微流控平台,旨在通过创建抗生素浓度梯度来实现快速单细胞 AST。微流控平台的优势在于能在一个无缝的工作流程中完成细菌和抗生素的混合、细胞包被、培养和细菌计数,从而为每种抗生素的药敏试验提供便利。首先,我们演示了用革兰氏阴性大肠杆菌和革兰氏阴性金黄色葡萄球菌快速测定几种抗生素的最低抑菌浓度(MIC),这使我们能够绕过耗时的细菌培养,将传统方法需要 1-2 天的 AST 缩短到 3 小时。此外,与美国临床和实验室标准协会(CLSI)的金标准 AST 方法(48 小时后才可使用)相比,我们对 10 种临床分离物(包括耐甲氧西林金黄色葡萄球菌(MRSA)和耐多药金黄色葡萄球菌(MDRSA))进行了评估,以分析其对临床重要抗生素的 MIC。此外,通过监测单个液滴中的单细胞,我们发现了基因相同的细胞之间的耐药性水平谱,揭示了同源群体中的表型异质性。这一发现不仅推进了临床诊断和治疗策略,还极大地促进了抗生素管理领域的发展,凸显了我们的方法在解决细菌耐药性问题上的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Lab on a Chip
Lab on a Chip 工程技术-化学综合
CiteScore
11.10
自引率
8.20%
发文量
434
审稿时长
2.6 months
期刊介绍: Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.
期刊最新文献
Automated Dynamic Inlet Microfluidics (ADIM) system: cost-effective biaxial nanoliter droplet on demand generation platform and its application in agglutination assays. Data storage based on the absence of nucleotides using a bacteriophage abortive infection system reverse transcriptase. Stitched textile-based microfluidics for wearable devices. A nanobody-based microfluidic chip for fast and automated purification of protein complexes. Detecting telomerase activity at the single-cell level using a CRISPR-Cas12a-based chip.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1