Comparison of visual quality after Q value-guided FS-LASIK and SMILE for correction of myopia with age-related accommodation deficiency.

Ruiyu Zhang, Yifei Yuan, Yu Zhang, Yueguo Chen
{"title":"Comparison of visual quality after Q value-guided FS-LASIK and SMILE for correction of myopia with age-related accommodation deficiency.","authors":"Ruiyu Zhang, Yifei Yuan, Yu Zhang, Yueguo Chen","doi":"10.1007/s00417-024-06627-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate differences in objective and subjective visual quality 12 months following Q value-guided (Custom-Q) femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) versus small incision lenticule extraction (SMILE) for correction of low-to-moderate myopia and compensate for age-related accommodation deficiency.</p><p><strong>Methods: </strong>Clinical data of 45 patients were analyzed, of whom 23 were treated with FS-LASIK and 22 with SMILE. At the 12-month follow-up, the distance, intermediate, and near visual acuities; objective and subjective refractions; Q factor; corneal higher-order aberrations (HOAs); defocus curve; contrast sensitivity; stereopsis and a subjective visual quality questionnaire were evaluated.</p><p><strong>Results: </strong>At 12 months postoperatively, the two groups had comparable binocular uncorrected distance and intermediate visual acuities (UDVA, UINA). A slightly better uncorrected near visual acuity (UNVA) was observed in the FS-LASIK group (P < 0.05), but patients reported equivalent near vision satisfaction and spectacle independence. Total HOAs and coma increased significantly in all treated eyes (P < 0.05). The Q value and spherical aberration (SA) became more positive, but the shifts were significant only in the SMILE group and the dominant eyes of the FS-LASIK group (P < 0.05). Binocular contrast sensitivity was better in the FS-LASIK group. No significant differences in visual disturbances were found between groups.</p><p><strong>Conclusion: </strong>For myopic patients with mild age-related accommodation deficiency, both FS-LASIK with Custom-Q protocol and SMILE could provide good efficacy, safety, predictability, and high patient satisfaction. The Custom-Q protocol could better preserve the original prolate shape of the cornea and achieve superior visual quality compared to SMILE.</p><p><strong>Key messages: </strong>What is known Both femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) have been widely applied in young myopic patients, with comparable efficacy and safety. Studies evaluating the clinical outcomes of FS-LASIK and SMILE in treating myopia with age-related accommodation insufficiency are lacking. What is new For myopic patients with mild age-related accommodation deficiency, both FS-LASIK with Custom-Q protocol and SMILE could provide good efficacy, safety, predictability, and high patient satisfaction. The Custom-Q protocol could better preserve the original prolate shape of the cornea and achieve superior visual quality compared to SMILE.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-024-06627-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate differences in objective and subjective visual quality 12 months following Q value-guided (Custom-Q) femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) versus small incision lenticule extraction (SMILE) for correction of low-to-moderate myopia and compensate for age-related accommodation deficiency.

Methods: Clinical data of 45 patients were analyzed, of whom 23 were treated with FS-LASIK and 22 with SMILE. At the 12-month follow-up, the distance, intermediate, and near visual acuities; objective and subjective refractions; Q factor; corneal higher-order aberrations (HOAs); defocus curve; contrast sensitivity; stereopsis and a subjective visual quality questionnaire were evaluated.

Results: At 12 months postoperatively, the two groups had comparable binocular uncorrected distance and intermediate visual acuities (UDVA, UINA). A slightly better uncorrected near visual acuity (UNVA) was observed in the FS-LASIK group (P < 0.05), but patients reported equivalent near vision satisfaction and spectacle independence. Total HOAs and coma increased significantly in all treated eyes (P < 0.05). The Q value and spherical aberration (SA) became more positive, but the shifts were significant only in the SMILE group and the dominant eyes of the FS-LASIK group (P < 0.05). Binocular contrast sensitivity was better in the FS-LASIK group. No significant differences in visual disturbances were found between groups.

Conclusion: For myopic patients with mild age-related accommodation deficiency, both FS-LASIK with Custom-Q protocol and SMILE could provide good efficacy, safety, predictability, and high patient satisfaction. The Custom-Q protocol could better preserve the original prolate shape of the cornea and achieve superior visual quality compared to SMILE.

Key messages: What is known Both femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) have been widely applied in young myopic patients, with comparable efficacy and safety. Studies evaluating the clinical outcomes of FS-LASIK and SMILE in treating myopia with age-related accommodation insufficiency are lacking. What is new For myopic patients with mild age-related accommodation deficiency, both FS-LASIK with Custom-Q protocol and SMILE could provide good efficacy, safety, predictability, and high patient satisfaction. The Custom-Q protocol could better preserve the original prolate shape of the cornea and achieve superior visual quality compared to SMILE.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Q 值引导的 FS-LASIK 和 SMILE 矫正老年性调节功能障碍近视后的视觉质量比较。
目的:研究Q值引导(Custom-Q)飞秒激光辅助激光原位角膜磨镶术(FS-LASIK)与小切口皮瓣摘除术(SMILE)在矫正中低度近视和补偿与年龄相关的调节力不足后12个月的客观和主观视觉质量的差异:分析了 45 名患者的临床数据,其中 23 人接受了 FS-LASIK 治疗,22 人接受了 SMILE 治疗。在 12 个月的随访中,对患者的远、中、近视力;客观和主观屈光度;Q 值因子;角膜高阶像差(HOA);离焦曲线;对比敏感度;立体视和主观视觉质量问卷进行了评估:术后12个月时,两组患者的双眼未矫正远视力和中视力(UDVA、UINA)相当。FS-LASIK组的未校正近视力(UNVA)稍好(P对于轻度年龄相关性调节功能障碍的近视患者,FS-LASIK 定制-Q 方案和 SMILE 都能提供良好的疗效、安全性、可预测性和较高的患者满意度。与SMILE相比,Custom-Q方案能更好地保持角膜的原始形状,并获得更好的视觉质量:已知信息 飞秒激光辅助激光原位角膜磨镶术(FS-LASIK)和小切口皮瓣摘除术(SMILE)已广泛应用于年轻近视患者,其疗效和安全性相当。目前还缺乏对 FS-LASIK 和 SMILE 治疗老年性调节功能不全近视的临床效果进行评估的研究。新进展 对于轻度年龄相关性调节力不足的近视患者,FS-LASIK 和 SMILE 都能提供良好的疗效、安全性、可预测性和较高的患者满意度。与SMILE相比,Custom-Q方案能更好地保留角膜的原始前凸形状,并获得更好的视觉质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
398
审稿时长
3 months
期刊介绍: Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.
期刊最新文献
Preliminary antifibrotic and vasoconstrictor effects of adrenaline in Schlemm's canal and suprachoroidal minimally invasive glaucoma surgery in primary open-angle glaucoma. A cost-minimization analysis of anti-VEGFs for the treatment of neovascular age-related macular degeneration in the Netherlands. Comparison of visual quality after Q value-guided FS-LASIK and SMILE for correction of myopia with age-related accommodation deficiency. Evaluation of peripheral retinal degenerations using ultra-widefield swept source optical coherence tomography. Outcomes of amniotic membrane transplant for refractory macular hole - an optical coherence tomography and autofluorescence long-term study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1