The Flip and Fix internal limiting flap technique versus the classic temporal flap for macular hole repair.

IF 2.1 4区 医学 Q2 OPHTHALMOLOGY Indian Journal of Ophthalmology Pub Date : 2024-11-01 Epub Date: 2024-09-10 DOI:10.4103/IJO.IJO_1155_24
Mohsen Abou Shousha, Mohamed M Lolah, Islam S H Ahmed
{"title":"The Flip and Fix internal limiting flap technique versus the classic temporal flap for macular hole repair.","authors":"Mohsen Abou Shousha, Mohamed M Lolah, Islam S H Ahmed","doi":"10.4103/IJO.IJO_1155_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe a novel technique of macular hole (MH) repair and compare it to the perfluorocarbon liquid (PFCL)-assisted temporal internal limiting membrane (ILM) flap technique.</p><p><strong>Methods: </strong>Twenty-two eyes of 22 patients with MH were randomized on a 1:1 basis into two groups. Group A cases were treated using the Flip and Fix technique, in which the single-layer ILM flap was flipped, flattened over the macula using PFCL, and fixed in place using two drops of autologous nonheparinized blood over the superonasal and inferonasal edges of the flap (away from the MH center). Group B patients had the classic temporal ILM flap technique without using the PFCL or autologous blood. All patients were followed up for a period of 6 months after the surgery.</p><p><strong>Results: </strong>No significant difference was observed in initial and final visual acuities between Groups A and B. Intraoperative flap displacement did not occur in Group A and occurred in two eyes in Group B (18.2%). One of them showed failed MH closure and required reoperation. These two cases had a final (W shape) MH closure and a worse final vision than the remaining cases, which had either a U shape or V shape final MH closure.</p><p><strong>Conclusions: </strong>The study results show that the Flip and Fix technique is as effective as the PFCL-assisted temporal ILM flap technique and is associated with less ILM flap displacement risk for the repair of macular holes.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_1155_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To describe a novel technique of macular hole (MH) repair and compare it to the perfluorocarbon liquid (PFCL)-assisted temporal internal limiting membrane (ILM) flap technique.

Methods: Twenty-two eyes of 22 patients with MH were randomized on a 1:1 basis into two groups. Group A cases were treated using the Flip and Fix technique, in which the single-layer ILM flap was flipped, flattened over the macula using PFCL, and fixed in place using two drops of autologous nonheparinized blood over the superonasal and inferonasal edges of the flap (away from the MH center). Group B patients had the classic temporal ILM flap technique without using the PFCL or autologous blood. All patients were followed up for a period of 6 months after the surgery.

Results: No significant difference was observed in initial and final visual acuities between Groups A and B. Intraoperative flap displacement did not occur in Group A and occurred in two eyes in Group B (18.2%). One of them showed failed MH closure and required reoperation. These two cases had a final (W shape) MH closure and a worse final vision than the remaining cases, which had either a U shape or V shape final MH closure.

Conclusions: The study results show that the Flip and Fix technique is as effective as the PFCL-assisted temporal ILM flap technique and is associated with less ILM flap displacement risk for the repair of macular holes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
黄斑孔修补术中的翻转固定内限制瓣技术与经典的颞部皮瓣对比。
目的:描述一种新型黄斑孔(MH)修复技术,并将其与全氟碳液(PFCL)辅助的颞侧内缘膜(ILM)瓣技术进行比较:将22名MH患者的22只眼睛按1:1随机分为两组。A 组病例采用翻转固定技术进行治疗,即翻转单层 ILM 皮瓣,使用 PFCL 将其压平在黄斑上,并在皮瓣的上鼻翼和下鼻翼边缘(远离 MH 中心)滴两滴自体无肝素化血液进行固定。B 组患者采用经典的颞侧 ILM 皮瓣技术,不使用 PFCL 或自体血。所有患者均在术后接受了为期 6 个月的随访:A组和B组的初始视力和最终视力无明显差异。A组未发生术中皮瓣移位,B组有两只眼(18.2%)发生术中皮瓣移位。其中一只眼的 MH 闭合失败,需要再次手术。这两个病例的 MH 最终闭合(W 形),最终视力比其余病例差,其余病例的 MH 最终闭合为 U 形或 V 形:研究结果表明,翻转固定技术与PFCL辅助的颞侧ILM瓣技术一样有效,而且在修复黄斑孔时ILM瓣移位风险较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
期刊最新文献
Association between gut microbiota and central retinal artery occlusion: A two-sample Mendelian randomization study. Clinical outcomes of topography-guided versus wavefront-optimized LASIK for correction of myopia and compound myopic astigmatism. Accuracy of Intraocular lens power calculation in pediatric traumatic cataract. Alterations in the tear film and ocular surface in pediatric migraine patients. Guidelines for setting up low-vision and rehabilitation services in India.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1