Application of a UV-vis spectrometer to investigate the effect of dissolution media on the diffusivity of small molecules and proteins.

IF 3.7 3区 医学 Q2 CHEMISTRY, MEDICINAL Journal of pharmaceutical sciences Pub Date : 2025-01-01 Epub Date: 2024-09-14 DOI:10.1016/j.xphs.2024.09.008
Hao Lou, Gang Hu, Xi Luan, Jill M Steinbach-Rankins, Michael J Hageman
{"title":"Application of a UV-vis spectrometer to investigate the effect of dissolution media on the diffusivity of small molecules and proteins.","authors":"Hao Lou, Gang Hu, Xi Luan, Jill M Steinbach-Rankins, Michael J Hageman","doi":"10.1016/j.xphs.2024.09.008","DOIUrl":null,"url":null,"abstract":"<p><p>To date, the commonly used methods for diffusion coefficient measurements have some hurdles that prevent them from being widely applied in pharmaceutical laboratories. This study aimed to modify a method developed by di Cagno et al. based on the use of a UV-Vis spectrometer and apply the method to investigate the effect of dissolution media on the diffusivity of small molecules and proteins. A total of five small molecules and two proteins in different aqueous media and polymer solutions were investigated in this study. By attaching a 3D-printed cover with an open slit to a standard UV-Vis cuvette, the incident UV light could only pass through the open slit to measure the local drug concentration. During the diffusion experiment, drug molecules diffused from the cuvette bottom to the slit. According to the concentration measured as a function of time, diffusion coefficient was calculated based on Fick's law of diffusion using the analytical and numerical approaches. As a result, diffusion coefficients could be accurately measured with high reproducibility. The results also suggested that different media could affect the diffusion coefficients of small molecules by < 10% and proteins by < 15%. Since the UV-Vis spectrometer is a routine instrument, this method can potentially be employed by many pharmaceutical laboratories for diffusion coefficient measurements.</p>","PeriodicalId":16741,"journal":{"name":"Journal of pharmaceutical sciences","volume":" ","pages":"256-264"},"PeriodicalIF":3.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.xphs.2024.09.008","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
引用次数: 0

Abstract

To date, the commonly used methods for diffusion coefficient measurements have some hurdles that prevent them from being widely applied in pharmaceutical laboratories. This study aimed to modify a method developed by di Cagno et al. based on the use of a UV-Vis spectrometer and apply the method to investigate the effect of dissolution media on the diffusivity of small molecules and proteins. A total of five small molecules and two proteins in different aqueous media and polymer solutions were investigated in this study. By attaching a 3D-printed cover with an open slit to a standard UV-Vis cuvette, the incident UV light could only pass through the open slit to measure the local drug concentration. During the diffusion experiment, drug molecules diffused from the cuvette bottom to the slit. According to the concentration measured as a function of time, diffusion coefficient was calculated based on Fick's law of diffusion using the analytical and numerical approaches. As a result, diffusion coefficients could be accurately measured with high reproducibility. The results also suggested that different media could affect the diffusion coefficients of small molecules by < 10% and proteins by < 15%. Since the UV-Vis spectrometer is a routine instrument, this method can potentially be employed by many pharmaceutical laboratories for diffusion coefficient measurements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用紫外可见光谱仪研究溶解介质对小分子和蛋白质扩散性的影响。
迄今为止,常用的扩散系数测量方法都存在一些障碍,无法广泛应用于制药实验室。本研究旨在修改 di Cagno 等人基于紫外可见光谱仪开发的方法,并将其应用于研究溶解介质对小分子和蛋白质扩散系数的影响。本研究共对不同水介质和聚合物溶液中的五种小分子和两种蛋白质进行了研究。通过在标准紫外可见比色皿上安装一个带有开口缝隙的 3D 打印盖,入射紫外光只能通过开口缝隙来测量局部药物浓度。在扩散实验中,药物分子从比色皿底部向狭缝扩散。根据测量到的浓度与时间的函数关系,利用分析和数值方法,根据菲克扩散定律计算出扩散系数。结果表明,扩散系数可以精确测量,并且具有很高的重现性。结果还表明,不同介质对小分子扩散系数的影响小于 10%,对蛋白质的影响小于 15%。由于紫外可见光谱仪是一种常规仪器,这种方法有可能被许多制药实验室用于扩散系数的测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.30
自引率
13.20%
发文量
367
审稿时长
33 days
期刊介绍: The Journal of Pharmaceutical Sciences will publish original research papers, original research notes, invited topical reviews (including Minireviews), and editorial commentary and news. The area of focus shall be concepts in basic pharmaceutical science and such topics as chemical processing of pharmaceuticals, including crystallization, lyophilization, chemical stability of drugs, pharmacokinetics, biopharmaceutics, pharmacodynamics, pro-drug developments, metabolic disposition of bioactive agents, dosage form design, protein-peptide chemistry and biotechnology specifically as these relate to pharmaceutical technology, and targeted drug delivery.
期刊最新文献
A Population Pharmacokinetic Analysis to Evaluate the Impact of Renal Impairment on the Pharmacokinetics of Iberdomide. Enzymatic hydrolysis of acyl glucuronide metabolites in human liver microsomes correlates to the risk of idiosyncratic drug toxicity. Molecular miscibility of ASD blend components: an evaluation of (the added value of) solid state NMR spectroscopy and relaxometry. Nuclear Magnetic Resonance Study of Monoclonal Antibodies Near an Oil-Water Interface. Two Recombinant Cytomegalovirus Antigens Formulated with the SPA14 Adjuvant System: Impact of Temperature, pH and Excipients on the Stability of each Antigen and Adjuvant Component.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1