Acurate neo2 is associated with a reduced inflammatory response in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation.

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Minerva cardiology and angiology Pub Date : 2024-10-01 DOI:10.23736/S2724-5683.24.06477-9
Juan G Chiabrando, Juan I Damonte, Sebastian Piñel, Cristian M Garmendia, Horacio Medina DE Chazal, Martin Denicolai, Giuliana Corna, Juan Valle Raleigh, Ignacio M Seropian, Carla R Agatiello
{"title":"Acurate neo2 is associated with a reduced inflammatory response in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation.","authors":"Juan G Chiabrando, Juan I Damonte, Sebastian Piñel, Cristian M Garmendia, Horacio Medina DE Chazal, Martin Denicolai, Giuliana Corna, Juan Valle Raleigh, Ignacio M Seropian, Carla R Agatiello","doi":"10.23736/S2724-5683.24.06477-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inflammation following transcatheter aortic valve implantation (TAVI) is associated with an increased risk of adverse outcomes. The aim of this study was to compare the inflammatory response between low radial force valves (Acurate neo2, Boston Scientific) and high radial force valves (Evolut R/Pro, Medtronic; SAPIEN Edwards Lifesciences; and Myval, Meril valves).</p><p><strong>Methods: </strong>We conducted a retrospective study of patients with severe aortic stenosis treated with TAVI between 2021 and 2022. The primary endpoint was the difference in the inflammatory response between low radial force valves and high radial force valves, measured as the difference between post-procedural and pre-procedural high-sensitivity C-reactive protein levels (hsCRP delta).</p><p><strong>Results: </strong>A total of 114 patients were included, of which 65 patients (57%) received a low radial force valve. The hsCRP delta was lower in the low radial force valve group compared to the high radial force valve group (8.7 [2.1-15.6] mg/L vs. 18.8 mg/dL [6.4-19] mg/L; P=0.003), due to a lower post-implantation hsCRP (8.9 [5.45-19.6] mg/L vs. 15.8 [9.8-27.3] mg/L; P=0.013). The incidence of new left bundle branch block (LBBB) after TAVI was lower in the low radial force valve group compared to the high radial force valve group (11 [17%] vs. 18 [37%]; P=0.020).</p><p><strong>Conclusions: </strong>Low radial force TAVI prostheses were associated with a lower inflammatory response, and a lower incidence of new LBBB compared to the radial force valve group, suggesting that inflammation may contribute to the increased risk of conduction disturbances.</p>","PeriodicalId":18668,"journal":{"name":"Minerva cardiology and angiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva cardiology and angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5683.24.06477-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Inflammation following transcatheter aortic valve implantation (TAVI) is associated with an increased risk of adverse outcomes. The aim of this study was to compare the inflammatory response between low radial force valves (Acurate neo2, Boston Scientific) and high radial force valves (Evolut R/Pro, Medtronic; SAPIEN Edwards Lifesciences; and Myval, Meril valves).

Methods: We conducted a retrospective study of patients with severe aortic stenosis treated with TAVI between 2021 and 2022. The primary endpoint was the difference in the inflammatory response between low radial force valves and high radial force valves, measured as the difference between post-procedural and pre-procedural high-sensitivity C-reactive protein levels (hsCRP delta).

Results: A total of 114 patients were included, of which 65 patients (57%) received a low radial force valve. The hsCRP delta was lower in the low radial force valve group compared to the high radial force valve group (8.7 [2.1-15.6] mg/L vs. 18.8 mg/dL [6.4-19] mg/L; P=0.003), due to a lower post-implantation hsCRP (8.9 [5.45-19.6] mg/L vs. 15.8 [9.8-27.3] mg/L; P=0.013). The incidence of new left bundle branch block (LBBB) after TAVI was lower in the low radial force valve group compared to the high radial force valve group (11 [17%] vs. 18 [37%]; P=0.020).

Conclusions: Low radial force TAVI prostheses were associated with a lower inflammatory response, and a lower incidence of new LBBB compared to the radial force valve group, suggesting that inflammation may contribute to the increased risk of conduction disturbances.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Acurate neo2 与接受经导管主动脉瓣植入术的重度主动脉瓣狭窄患者炎症反应的减少有关。
背景:经导管主动脉瓣植入术(TAVI)后的炎症与不良预后风险增加有关。本研究旨在比较低径向力瓣膜(Acurate neo2,波士顿科学公司)和高径向力瓣膜(Evolut R/Pro,美敦力公司;SAPIEN Edwards Lifesciences;Myval,梅里尔瓣膜)之间的炎症反应:我们对2021年至2022年间接受TAVI治疗的重度主动脉瓣狭窄患者进行了一项回顾性研究。主要终点是低径向力瓣膜和高径向力瓣膜之间炎症反应的差异,以手术后和手术前高敏C反应蛋白水平(hsCRP delta)的差异来衡量:结果:共纳入114名患者,其中65名患者(57%)接受了低径向力瓣膜。与高桡动脉力瓣膜组相比,低桡动脉力瓣膜组的 hsCRP delta 更低(8.7 [2.1-15.6] mg/L vs. 18.8 mg/dL [6.4-19] mg/L;P=0.003),这是因为植入后 hsCRP 更低(8.9 [5.45-19.6] mg/L vs. 15.8 [9.8-27.3] mg/L;P=0.013)。与高径向力瓣膜组相比,低径向力瓣膜组TAVI术后新发左束支传导阻滞(LBBB)的发生率较低(11 [17%] vs. 18 [37%];P=0.020):结论:与桡动脉力瓣膜组相比,低桡动脉力TAVI假体与较低的炎症反应和较低的新发LBBB发生率相关,这表明炎症可能是导致传导障碍风险增加的原因之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Minerva cardiology and angiology
Minerva cardiology and angiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
18.80%
发文量
118
期刊最新文献
Acurate neo2 is associated with a reduced inflammatory response in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation. Association between instantaneous heart rate sequence during the awake period and cardiovascular events: a study based on Sleep Heart Health Study. Cardiology 2.0: the (r)age of the machines? Clinical implications of Sokolow-Lyon voltage less than 3.5 mV in patients who have undergone transcatheter aortic valve replacement. Do publications of machine learning models justify the enthusiasm they generate?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1