Validation of the eye screening tool GoCheck Kids for the detection of amblyopia risk factors in toddlers in Flanders

IF 1.2 4区 医学 Q3 OPHTHALMOLOGY Journal of Aapos Pub Date : 2024-10-01 DOI:10.1016/j.jaapos.2024.104008
Hanne Otto MSc , Maaike Deschoemaeker MD , Bart Van Overmeire PhD, MD , Ingele Casteels PhD, MD , Catherine Cassiman PhD, MD
{"title":"Validation of the eye screening tool GoCheck Kids for the detection of amblyopia risk factors in toddlers in Flanders","authors":"Hanne Otto MSc ,&nbsp;Maaike Deschoemaeker MD ,&nbsp;Bart Van Overmeire PhD, MD ,&nbsp;Ingele Casteels PhD, MD ,&nbsp;Catherine Cassiman PhD, MD","doi":"10.1016/j.jaapos.2024.104008","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>To assess the validity of the GoCheck Kids photoscreening application (Gobiquity Mobile Health, Scottdale, AZ) on iPhone, which was used (2018-2022) as standard of care by Child and Family (Kind en Gezin) to detect amblyopia risk factors in children 12-30 months of age.</div></div><div><h3>Methods</h3><div>Between August 2021 and May 2022, 453 children 11-16 months of age underwent a confirmatory ophthalmic examination within 2 months of GoCheck Kids photoscreening at Child and Family, Flanders, Belgium. Additionally, manual review was performed by specialists of GoCheck Kids. Diagnostic metrics were assessed using the 2013 criteria of the American Association for Pediatric Ophthalmology and Strabismus as reference.</div></div><div><h3>Results</h3><div>Specificity was similar for automatic screening with or without manual review: 90.0% (95% CI, 87.6%-92.3%) and 90.3% (95% CI, 88.0%-92.7%), respectively. Sensitivity was estimated at 52.0% (95% CI, 35.6%-68.4%) for automatic grading and 56.0% (95% CI, 39.7%-72.3%) after manual review. Positive predictive values for automatic screening and manual review were, respectively, 23.2% (95% CI, 13.9-32.5) and 25.5% (95% CI, 15.8-35.1). Negative predictive values for automatic screening and manual review were, respectively, 97.0% (95% CI, 95.6-98.4) and 97.2 (95% CI, 95.8-98.6).</div></div><div><h3>Conclusions</h3><div>In our study cohort of children around 12 months of age, the GoCheck Kids application had a specificity of 90% for the targeted amblyopia risk factors, with sensitivity just over 50%.</div></div>","PeriodicalId":50261,"journal":{"name":"Journal of Aapos","volume":"28 5","pages":"Article 104008"},"PeriodicalIF":1.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aapos","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1091853124003057","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To assess the validity of the GoCheck Kids photoscreening application (Gobiquity Mobile Health, Scottdale, AZ) on iPhone, which was used (2018-2022) as standard of care by Child and Family (Kind en Gezin) to detect amblyopia risk factors in children 12-30 months of age.

Methods

Between August 2021 and May 2022, 453 children 11-16 months of age underwent a confirmatory ophthalmic examination within 2 months of GoCheck Kids photoscreening at Child and Family, Flanders, Belgium. Additionally, manual review was performed by specialists of GoCheck Kids. Diagnostic metrics were assessed using the 2013 criteria of the American Association for Pediatric Ophthalmology and Strabismus as reference.

Results

Specificity was similar for automatic screening with or without manual review: 90.0% (95% CI, 87.6%-92.3%) and 90.3% (95% CI, 88.0%-92.7%), respectively. Sensitivity was estimated at 52.0% (95% CI, 35.6%-68.4%) for automatic grading and 56.0% (95% CI, 39.7%-72.3%) after manual review. Positive predictive values for automatic screening and manual review were, respectively, 23.2% (95% CI, 13.9-32.5) and 25.5% (95% CI, 15.8-35.1). Negative predictive values for automatic screening and manual review were, respectively, 97.0% (95% CI, 95.6-98.4) and 97.2 (95% CI, 95.8-98.6).

Conclusions

In our study cohort of children around 12 months of age, the GoCheck Kids application had a specificity of 90% for the targeted amblyopia risk factors, with sensitivity just over 50%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
验证 GoCheck Kids 眼科筛查工具,以发现佛兰德幼儿弱视的风险因素。
目的:评估iPhone上的GoCheck Kids照片筛查应用程序(Gobiquity Mobile Health, Scottdale, AZ)的有效性,该应用程序被儿童与家庭(Kind en Gezin)作为标准护理方法(2018-2022年),用于检测12-30个月大儿童的弱视风险因素:2021年8月至2022年5月期间,453名11-16个月大的儿童在比利时佛兰德斯儿童与家庭组织进行GoCheck Kids照片筛查后2个月内接受了眼科确诊检查。此外,GoCheck Kids 的专家还进行了人工复查。诊断指标以美国儿科眼科和斜视协会 2013 年标准为参考进行评估:有无人工审核的自动筛查的特异性相似:结果:有无人工复查的自动筛查的特异性相似:分别为 90.0%(95% CI,87.6%-92.3%)和 90.3%(95% CI,88.0%-92.7%)。自动分级的灵敏度估计为 52.0%(95% CI,35.6%-68.4%),人工复查后的灵敏度估计为 56.0%(95% CI,39.7%-72.3%)。自动筛查和人工复查的阳性预测值分别为 23.2%(95% CI,13.9-32.5)和 25.5%(95% CI,15.8-35.1)。自动筛查和人工复查的阴性预测值分别为 97.0% (95% CI, 95.6-98.4) 和 97.2 (95% CI, 95.8-98.6):我们的研究对象是 12 个月左右的儿童,GoCheck Kids 应用程序对目标弱视风险因素的特异性为 90%,灵敏度略高于 50%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Aapos
Journal of Aapos 医学-小儿科
CiteScore
2.40
自引率
12.50%
发文量
159
审稿时长
55 days
期刊介绍: Journal of AAPOS presents expert information on children''s eye diseases and on strabismus as it affects all age groups. Major articles by leading experts in the field cover clinical and investigative studies, treatments, case reports, surgical techniques, descriptions of instrumentation, current concept reviews, and new diagnostic techniques. The Journal is the official publication of the American Association for Pediatric Ophthalmology and Strabismus.
期刊最新文献
Evaluation of 3D tablet-based stereoacuity test asteroid in children with normal and abnormal visual acuity. Orbital hematoma due to vitamin K deficiency in an infant. The effect of inconsistent guidelines on variability in pediatric vision screening referral outcomes. Trigemino-abducens synkinesis: serial review over 4 years. Using machine learning to identify pediatric ophthalmologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1