Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study.

Q4 Medicine Critical care explorations Pub Date : 2024-09-13 eCollection Date: 2024-09-01 DOI:10.1097/CCE.0000000000001133
Sicheng Hao, Katelyn Dempsey, João Matos, Christopher E Cox, Veronica Rotemberg, Judy W Gichoya, Warren Kibbe, Chuan Hong, An-Kwok Ian Wong
{"title":"Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study.","authors":"Sicheng Hao, Katelyn Dempsey, João Matos, Christopher E Cox, Veronica Rotemberg, Judy W Gichoya, Warren Kibbe, Chuan Hong, An-Kwok Ian Wong","doi":"10.1097/CCE.0000000000001133","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Pulse oximetry, a ubiquitous vital sign in modern medicine, has inequitable accuracy that disproportionately affects minority Black and Hispanic patients, with associated increases in mortality, organ dysfunction, and oxygen therapy. Previous retrospective studies used self-reported race or ethnicity as a surrogate for skin tone which is believed to be the root cause of the disparity. Our objective was to determine the utility of skin tone in explaining pulse oximetry discrepancies.</p><p><strong>Design: </strong>Prospective cohort study.</p><p><strong>Setting: </strong>Patients were eligible if they had pulse oximetry recorded up to 5 minutes before arterial blood gas (ABG) measurements. Skin tone was measured using administered visual scales, reflectance colorimetry, and reflectance spectrophotometry.</p><p><strong>Participants: </strong>Admitted hospital patients at Duke University Hospital.</p><p><strong>Interventions: </strong>None.</p><p><strong>Measurements and main results: </strong>Sao2-Spo2 bias, variation of bias, and accuracy root mean square, comparing pulse oximetry, and ABG measurements. Linear mixed-effects models were fitted to estimate Sao2-Spo2 bias while accounting for clinical confounders.One hundred twenty-eight patients (57 Black, 56 White) with 521 ABG-pulse oximetry pairs were recruited. Skin tone data were prospectively collected using six measurement methods, generating eight measurements. The collected skin tone measurements were shown to yield differences among each other and overlap with self-reported racial groups, suggesting that skin tone could potentially provide information beyond self-reported race. Among the eight skin tone measurements in this study, and compared with self-reported race, the Monk Scale had the best relationship with differences in pulse oximetry bias (point estimate: -2.40%; 95% CI, -4.32% to -0.48%; p = 0.01) when comparing patients with lighter and dark skin tones.</p><p><strong>Conclusions: </strong>We found clinical performance differences in pulse oximetry, especially in darker skin tones. Additional studies are needed to determine the relative contributions of skin tone measures and other potential factors on pulse oximetry discrepancies.</p>","PeriodicalId":93957,"journal":{"name":"Critical care explorations","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical care explorations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/CCE.0000000000001133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Pulse oximetry, a ubiquitous vital sign in modern medicine, has inequitable accuracy that disproportionately affects minority Black and Hispanic patients, with associated increases in mortality, organ dysfunction, and oxygen therapy. Previous retrospective studies used self-reported race or ethnicity as a surrogate for skin tone which is believed to be the root cause of the disparity. Our objective was to determine the utility of skin tone in explaining pulse oximetry discrepancies.

Design: Prospective cohort study.

Setting: Patients were eligible if they had pulse oximetry recorded up to 5 minutes before arterial blood gas (ABG) measurements. Skin tone was measured using administered visual scales, reflectance colorimetry, and reflectance spectrophotometry.

Participants: Admitted hospital patients at Duke University Hospital.

Interventions: None.

Measurements and main results: Sao2-Spo2 bias, variation of bias, and accuracy root mean square, comparing pulse oximetry, and ABG measurements. Linear mixed-effects models were fitted to estimate Sao2-Spo2 bias while accounting for clinical confounders.One hundred twenty-eight patients (57 Black, 56 White) with 521 ABG-pulse oximetry pairs were recruited. Skin tone data were prospectively collected using six measurement methods, generating eight measurements. The collected skin tone measurements were shown to yield differences among each other and overlap with self-reported racial groups, suggesting that skin tone could potentially provide information beyond self-reported race. Among the eight skin tone measurements in this study, and compared with self-reported race, the Monk Scale had the best relationship with differences in pulse oximetry bias (point estimate: -2.40%; 95% CI, -4.32% to -0.48%; p = 0.01) when comparing patients with lighter and dark skin tones.

Conclusions: We found clinical performance differences in pulse oximetry, especially in darker skin tones. Additional studies are needed to determine the relative contributions of skin tone measures and other potential factors on pulse oximetry discrepancies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.70
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Statistical Power and Performance of Strategies to Analyze Composites of Survival and Duration of Ventilation in Clinical Trials. Erratum: Pericardiocentesis, Chest Tube Insertion, and Needle Thoracostomy During Resuscitation of Nontraumatic Adult In-Hospital Cardiac Arrest: A Retrospective Cohort Study: Erratum. Pericardiocentesis, Chest Tube Insertion, and Needle Thoracostomy During Resuscitation of Nontraumatic Adult In-Hospital Cardiac Arrest: A Retrospective Cohort Study: Erratum. Characterizing the Use of Time-Limited Trials in Patients With Acute Respiratory Failure: A Prospective, Single-Center Observational Study. Utility of Skin Tone on Pulse Oximetry in Critically Ill Patients: A Prospective Cohort Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1