Xiuquan Du , Xuebin Xu , Jiajia Chen , Xuejun Zhang , Lei Li , Heng Liu , Shuo Li
{"title":"UM-Net: Rethinking ICGNet for polyp segmentation with uncertainty modeling","authors":"Xiuquan Du , Xuebin Xu , Jiajia Chen , Xuejun Zhang , Lei Li , Heng Liu , Shuo Li","doi":"10.1016/j.media.2024.103347","DOIUrl":null,"url":null,"abstract":"<div><div>Automatic segmentation of polyps from colonoscopy images plays a critical role in the early diagnosis and treatment of colorectal cancer. Nevertheless, some bottlenecks still exist. In our previous work, we mainly focused on polyps with intra-class inconsistency and low contrast, using ICGNet to solve them. Due to the different equipment, specific locations and properties of polyps, the color distribution of the collected images is inconsistent. ICGNet was designed primarily with reverse-contour guide information and local–global context information, ignoring this inconsistent color distribution, which leads to overfitting problems and makes it difficult to focus only on beneficial image content. In addition, a trustworthy segmentation model should not only produce high-precision results but also provide a measure of uncertainty to accompany its predictions so that physicians can make informed decisions. However, ICGNet only gives the segmentation result and lacks the uncertainty measure. To cope with these novel bottlenecks, we further extend the original ICGNet to a comprehensive and effective network (UM-Net) with two main contributions that have been proved by experiments to have substantial practical value. Firstly, we employ a color transfer operation to weaken the relationship between color and polyps, making the model more concerned with the shape of the polyps. Secondly, we provide the uncertainty to represent the reliability of the segmentation results and use variance to rectify uncertainty. Our improved method is evaluated on five polyp datasets, which shows competitive results compared to other advanced methods in both learning ability and generalization capability. The source code is available at <span><span>https://github.com/dxqllp/UM-Net</span><svg><path></path></svg></span>.</div></div>","PeriodicalId":18328,"journal":{"name":"Medical image analysis","volume":null,"pages":null},"PeriodicalIF":10.7000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical image analysis","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S136184152400272X","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, ARTIFICIAL INTELLIGENCE","Score":null,"Total":0}
引用次数: 0
Abstract
Automatic segmentation of polyps from colonoscopy images plays a critical role in the early diagnosis and treatment of colorectal cancer. Nevertheless, some bottlenecks still exist. In our previous work, we mainly focused on polyps with intra-class inconsistency and low contrast, using ICGNet to solve them. Due to the different equipment, specific locations and properties of polyps, the color distribution of the collected images is inconsistent. ICGNet was designed primarily with reverse-contour guide information and local–global context information, ignoring this inconsistent color distribution, which leads to overfitting problems and makes it difficult to focus only on beneficial image content. In addition, a trustworthy segmentation model should not only produce high-precision results but also provide a measure of uncertainty to accompany its predictions so that physicians can make informed decisions. However, ICGNet only gives the segmentation result and lacks the uncertainty measure. To cope with these novel bottlenecks, we further extend the original ICGNet to a comprehensive and effective network (UM-Net) with two main contributions that have been proved by experiments to have substantial practical value. Firstly, we employ a color transfer operation to weaken the relationship between color and polyps, making the model more concerned with the shape of the polyps. Secondly, we provide the uncertainty to represent the reliability of the segmentation results and use variance to rectify uncertainty. Our improved method is evaluated on five polyp datasets, which shows competitive results compared to other advanced methods in both learning ability and generalization capability. The source code is available at https://github.com/dxqllp/UM-Net.
期刊介绍:
Medical Image Analysis serves as a platform for sharing new research findings in the realm of medical and biological image analysis, with a focus on applications of computer vision, virtual reality, and robotics to biomedical imaging challenges. The journal prioritizes the publication of high-quality, original papers contributing to the fundamental science of processing, analyzing, and utilizing medical and biological images. It welcomes approaches utilizing biomedical image datasets across all spatial scales, from molecular/cellular imaging to tissue/organ imaging.