Preliminary study of feasibility of surface-guided radiotherapy with concurrent tumor treating fields for glioblastoma: region of interest.

IF 3.3 2区 医学 Q2 ONCOLOGY Radiation Oncology Pub Date : 2024-09-27 DOI:10.1186/s13014-024-02525-3
Jiajun Zheng, Geng Xu, Wenjie Guo, Yuanyuan Wang, Jianfeng Wu, Dan Zong, Boyang Ding, Li Sun, Xia He
{"title":"Preliminary study of feasibility of surface-guided radiotherapy with concurrent tumor treating fields for glioblastoma: region of interest.","authors":"Jiajun Zheng, Geng Xu, Wenjie Guo, Yuanyuan Wang, Jianfeng Wu, Dan Zong, Boyang Ding, Li Sun, Xia He","doi":"10.1186/s13014-024-02525-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the impact of the residual setup errors from differently shaped region of interest (ROI) and investigate if surface-guided setup can be used in radiotherapy with concurrent tumor treating fields (TTFields) for glioblastoma.</p><p><strong>Methods: </strong>Fifteen patients undergone glioblastoma radiotherapy with concurrent TTFields were involved. Firstly, four shapes of region of interest (ROI) (strip-shaped, T-shaped, <math><mo>⊥</mo></math> -shaped and cross-shaped) with medium size relative to the whole face were defined dedicate for patients wearing TTFields transducer arrays. Then, ROI-shape-dependent residual setup errors in six degrees were evaluated using an anthropomorphic head and neck phantom taking CBCT data as reference. Finally, the four types of residual setup errors were converted into corresponding dosimetry deviations (including the target coverage and the organ at risk sparing) of the fifteen radiotherapy plans using a feasible and robust geometric-transform-based method.</p><p><strong>Results: </strong>The algebraic sum of the average residual setup errors in six degrees (mm in translational directions and ° in rotational directions) of the four types were 6.9, 1.1, 4.1 and 3.5 respectively. In terms of the ROI-shape-dependent dosimetry deviations, the D<sub>98%</sub> of PTV dropped off by (3.4 ± 2.0)% (p < 0.05), (0.3 ± 0.5)% (p < 0.05), (0.9 ± 0.9)% (p < 0.05) and (1.1 ± 0.8)% (p < 0.05). The D<sub>98%</sub> of CTV dropped off by (0.5 ± 0.6)% (p < 0.05) for the strip-shaped ROI while remained unchanged for others.</p><p><strong>Conclusion: </strong>Surface-guided setup is feasible in radiotherapy with concurrent TTFields and a medium-sized T-shaped ROI is appropriate for the surface-based guidance.</p>","PeriodicalId":49639,"journal":{"name":"Radiation Oncology","volume":"19 1","pages":"129"},"PeriodicalIF":3.3000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11430246/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13014-024-02525-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the impact of the residual setup errors from differently shaped region of interest (ROI) and investigate if surface-guided setup can be used in radiotherapy with concurrent tumor treating fields (TTFields) for glioblastoma.

Methods: Fifteen patients undergone glioblastoma radiotherapy with concurrent TTFields were involved. Firstly, four shapes of region of interest (ROI) (strip-shaped, T-shaped, -shaped and cross-shaped) with medium size relative to the whole face were defined dedicate for patients wearing TTFields transducer arrays. Then, ROI-shape-dependent residual setup errors in six degrees were evaluated using an anthropomorphic head and neck phantom taking CBCT data as reference. Finally, the four types of residual setup errors were converted into corresponding dosimetry deviations (including the target coverage and the organ at risk sparing) of the fifteen radiotherapy plans using a feasible and robust geometric-transform-based method.

Results: The algebraic sum of the average residual setup errors in six degrees (mm in translational directions and ° in rotational directions) of the four types were 6.9, 1.1, 4.1 and 3.5 respectively. In terms of the ROI-shape-dependent dosimetry deviations, the D98% of PTV dropped off by (3.4 ± 2.0)% (p < 0.05), (0.3 ± 0.5)% (p < 0.05), (0.9 ± 0.9)% (p < 0.05) and (1.1 ± 0.8)% (p < 0.05). The D98% of CTV dropped off by (0.5 ± 0.6)% (p < 0.05) for the strip-shaped ROI while remained unchanged for others.

Conclusion: Surface-guided setup is feasible in radiotherapy with concurrent TTFields and a medium-sized T-shaped ROI is appropriate for the surface-based guidance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胶质母细胞瘤表面引导放疗与同期肿瘤治疗场可行性的初步研究:感兴趣区。
目的评估不同形状的感兴趣区(ROI)残留设置误差的影响,并研究表面引导设置是否可用于胶质母细胞瘤同期肿瘤治疗野(TTFields)放射治疗:方法:15 名患者接受了胶质母细胞瘤同期肿瘤治疗野(TTFields)放疗。首先,为佩戴 TTFields 换能器阵列的患者定义了四种相对于整个面部中等大小的感兴趣区(ROI)形状(条形、T 形、⊥形和十字形)。然后,以 CBCT 数据为参考,使用拟人头颈模型评估了六度内与 ROI 形状相关的残余设置误差。最后,使用一种可行且稳健的基于几何变换的方法,将四种类型的残余设置误差转换为 15 种放疗计划的相应剂量测定偏差(包括靶区覆盖率和危险器官的疏通率):四种类型的六度(平移方向为毫米,旋转方向为°)平均残余设置误差的代数和分别为 6.9、1.1、4.1 和 3.5。就依赖于 ROI 形状的剂量测定偏差而言,PTV 的 D98% 下降了 (3.4 ± 2.0)% (p CTV 的 98% 下降了 (0.5 ± 0.6)% (p 结论:体表引导设置在同期TTF场放疗中是可行的,中等大小的T形ROI适合体表引导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Oncology
Radiation Oncology ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
6.50
自引率
2.80%
发文量
181
审稿时长
3-6 weeks
期刊介绍: Radiation Oncology encompasses all aspects of research that impacts on the treatment of cancer using radiation. It publishes findings in molecular and cellular radiation biology, radiation physics, radiation technology, and clinical oncology.
期刊最新文献
The impact of radiation-related lymphocyte recovery on the prognosis of locally advanced esophageal squamous cell carcinoma patients: a retrospective analysis. Correction: Artificial intelligence contouring in radiotherapy for organs-at-risk and lymph node areas. Deep learning-based synthetic CT for dosimetric monitoring of combined conventional radiotherapy and lattice boost in large lung tumors. Correction: The significance of risk stratification through nomogram-based assessment in determining postmastectomy radiotherapy for patients diagnosed with pT1 - 2N1M0 breast cancer. Sequential or simultaneous-integrated boost in early-stage breast cancer patients: trade-offs between skin toxicity and risk of compromised coverage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1