Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2024-09-23 eCollection Date: 2024-01-01 DOI:10.2147/OPTH.S456660
Sri Ganesh, Sheetal Brar, Supriya Sriganesh, Hemali D Bhavsar
{"title":"Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems.","authors":"Sri Ganesh, Sheetal Brar, Supriya Sriganesh, Hemali D Bhavsar","doi":"10.2147/OPTH.S456660","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems.</p><p><strong>Setting: </strong>Nethradhama Superspeciality Eye Hospital, Bangalore, India.</p><p><strong>Study design: </strong>Prospective, interventional, 3-arm, randomized comparison study.</p><p><strong>Methods: </strong>A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1-2, and n = 30 eyes had grade 3-4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1-4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed.</p><p><strong>Results: </strong>Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable.</p><p><strong>Conclusion: </strong>The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems.</p><p><strong>Ctri registration number: </strong>CTRI/2022/01/039296.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11430833/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S456660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems.

Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India.

Study design: Prospective, interventional, 3-arm, randomized comparison study.

Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1-2, and n = 30 eyes had grade 3-4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1-4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed.

Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable.

Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems.

Ctri registration number: CTRI/2022/01/039296.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quatera 700 与 Centurion 和 Signature Pro 乳化系统手术性能的临床比较研究。
目的:比较Quatera 700与Centurion和Signature Pro超声乳化系统的术中手术性能:研究设计:研究设计:前瞻性、介入性、三臂随机对比研究:方法:共招募了 180 只符合资格标准的非连续眼。采用上述每种系统分别为n=60只眼进行了手术,其中n=30只眼的LOCS III为1-2级,n=30只眼的核密度为3-4级。由一名经验丰富的外科医生进行乳化手术并植入可折叠人工晶体。对房室稳定性评分(1-4分,4分为最差)、每例手术的液体周转率、涌波发生率和术中并发症进行了评估:术中,Quatera 700 在软性白内障组和致密白内障组的平均房室稳定性评分明显优于其他两台机器(P < 0.001)。在软性和致密白内障组中,Quatera 700 的总手术时间(TPT)明显低于 Signature Pro,而与 Centurion 相当。与 Signature Pro 相比,Quatera 700 在致密白内障组的平均液体周转率明显降低(p = 0.04),而 phaco 和 I/A 的综合时间也明显降低(p = 0.01)。一只使用 Signature Pro 的眼睛和两只使用 Centurion 的眼睛由于激增而出现 PCR。POD-1的平均角膜清晰度评分以及2周和6个月时的镜下计数相当:结论:与 Signature Pro 相比,新型 Quatera 700 系统的 TPT、液体周转和 phaco + I/A 时间更短,而在这些参数方面的性能与 Centurion 相当。此外,与其他两种系统相比,外科医生对术中腔室稳定性的评分最高:CTRI/2022/01/039296。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
期刊最新文献
Association Between Particulate Matter Pollutants and Ophthalmology Visits for Ocular Surface Irritation and Allergy. The Cutting Efficiency of a Hybrid Phacoemulsification Tip Using High and Low Intraocular Pressure Settings in Different Grades of Cataract. Comparison of Large Language Models in Diagnosis and Management of Challenging Clinical Cases. Enhancing OCT Reliability: The Role of Eye-Tracking in Achieving Consistent Retinal Measurements [Letter]. Baseline Characteristics and Clinical Outcomes of Patients Seen Through the Free Diabetes Screening (FDS) Program.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1