Esraa S Ahmed, Eman A Bahgat, Hanaa Saleh, Mona E El Sharkasy, Fathalla Belal
{"title":"Novel quantum dots-based assay for the determination of anti-hypertensive drugs minoxidil and timolol in different matrices.","authors":"Esraa S Ahmed, Eman A Bahgat, Hanaa Saleh, Mona E El Sharkasy, Fathalla Belal","doi":"10.1016/j.saa.2024.125141","DOIUrl":null,"url":null,"abstract":"<p><p>The present work reports a sensitive, affordable, and ecologically friendly spectrofluorimetric method for the assessment of two antihypertensive medications, namely minoxidil and timolol. Blue-emitting sulfur and nitrogen co-doped carbon quantum dots (S,N-CQDs) were generated by exposing soluble starch and thiourea to a 15-minute microwave treatment. The so- prepared nanodots displayed fluorescence at 276/430 nm with a quantum yield of 22 %. Inspection of the so-prepared nano-sensor verified their doping with nitrogen and sulfur, and their size was in the range of 4.5-9.03 nm. The proposed method was found to be rectilinear in the range of 0.20-5.0 and 2.0-30.0 µg/mL, with LOQs of 0.16 and 0.82 µg/mL for minoxidil and timolol, respectively. The developed method was employed to assess the concentrations of minoxidil and timolol in their pharmaceutical formulations, with %recoveries varying between 99.00 % and 101.94 %, and low RSD values (less than 2 %). The high sensitivity of the developed method allowed its use for timolol measurement in artificial aqueous humor, with % recoveries between 97.60 %.and 101.57 %. The study further examined how each analyte interacted with the prepared dots, leading to a quenching of their fluorescence. Additionally, an interference study was utilized to evaluate the specificity of the proposed approach through determining analyte levels in the existence of common additives, co-formulated drugs, and co-administered drugs. The analytical eco-scale, GAPI and AGREE assessment techniques were utilized to confirm the suggested method greenness.</p>","PeriodicalId":94213,"journal":{"name":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","volume":"325 ","pages":"125141"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.saa.2024.125141","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The present work reports a sensitive, affordable, and ecologically friendly spectrofluorimetric method for the assessment of two antihypertensive medications, namely minoxidil and timolol. Blue-emitting sulfur and nitrogen co-doped carbon quantum dots (S,N-CQDs) were generated by exposing soluble starch and thiourea to a 15-minute microwave treatment. The so- prepared nanodots displayed fluorescence at 276/430 nm with a quantum yield of 22 %. Inspection of the so-prepared nano-sensor verified their doping with nitrogen and sulfur, and their size was in the range of 4.5-9.03 nm. The proposed method was found to be rectilinear in the range of 0.20-5.0 and 2.0-30.0 µg/mL, with LOQs of 0.16 and 0.82 µg/mL for minoxidil and timolol, respectively. The developed method was employed to assess the concentrations of minoxidil and timolol in their pharmaceutical formulations, with %recoveries varying between 99.00 % and 101.94 %, and low RSD values (less than 2 %). The high sensitivity of the developed method allowed its use for timolol measurement in artificial aqueous humor, with % recoveries between 97.60 %.and 101.57 %. The study further examined how each analyte interacted with the prepared dots, leading to a quenching of their fluorescence. Additionally, an interference study was utilized to evaluate the specificity of the proposed approach through determining analyte levels in the existence of common additives, co-formulated drugs, and co-administered drugs. The analytical eco-scale, GAPI and AGREE assessment techniques were utilized to confirm the suggested method greenness.