Clinical Outcomes of Left Ventricular Assist Device Bleeding Complication.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL ASAIO Journal Pub Date : 2024-09-26 DOI:10.1097/MAT.0000000000002317
Shusuke Imaoka, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Koichi Toda, Shigeru Miyagawa
{"title":"Clinical Outcomes of Left Ventricular Assist Device Bleeding Complication.","authors":"Shusuke Imaoka, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Koichi Toda, Shigeru Miyagawa","doi":"10.1097/MAT.0000000000002317","DOIUrl":null,"url":null,"abstract":"<p><p>Bleeding complications have emerged as major causes of morbidity and mortality in patients with implantable left ventricular assist devices (LVAD). We hypothesized that the hemodynamics after LVAD implantation may influence the occurrence of bleeding complications after LVAD implantation. We retrospectively evaluated 78 patients who underwent continuous-flow LVAD implantation and hemodynamic ramp test after LVAD implantation between July 2017 and July 2023 at Osaka University. The bleeding complication occurred in 13 patients. The rates of freedom from bleeding complications at 1, 3, and 5 years were 94%, 85%, and 74%. Gastrointestinal bleeding, nose bleeding, and intraperitoneal hemorrhage occurred in six, three, and two patients, respectively. Preoperative average brachial-ankle pulse wave velocity (baPWV) was positively associated with bleeding complication (1,276 ± 280 vs. 1,098 ± 190 cm/s p = 0.04). In the hemodynamic ramp test, systemic vascular resistance (SVR) in patients with bleeding complications was higher than that in patients without bleeding complications (SVR: 1,359 ± 341 vs. 1,150 ± 217 dyne sec/cm5, p = 0.01). High preoperative baPWV and high SVR in the hemodynamic ramp test were significantly associated with bleeding complications after LVAD implantation. Arteriosclerosis is a risk factor for bleeding complications after LVAD implantation.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002317","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Bleeding complications have emerged as major causes of morbidity and mortality in patients with implantable left ventricular assist devices (LVAD). We hypothesized that the hemodynamics after LVAD implantation may influence the occurrence of bleeding complications after LVAD implantation. We retrospectively evaluated 78 patients who underwent continuous-flow LVAD implantation and hemodynamic ramp test after LVAD implantation between July 2017 and July 2023 at Osaka University. The bleeding complication occurred in 13 patients. The rates of freedom from bleeding complications at 1, 3, and 5 years were 94%, 85%, and 74%. Gastrointestinal bleeding, nose bleeding, and intraperitoneal hemorrhage occurred in six, three, and two patients, respectively. Preoperative average brachial-ankle pulse wave velocity (baPWV) was positively associated with bleeding complication (1,276 ± 280 vs. 1,098 ± 190 cm/s p = 0.04). In the hemodynamic ramp test, systemic vascular resistance (SVR) in patients with bleeding complications was higher than that in patients without bleeding complications (SVR: 1,359 ± 341 vs. 1,150 ± 217 dyne sec/cm5, p = 0.01). High preoperative baPWV and high SVR in the hemodynamic ramp test were significantly associated with bleeding complications after LVAD implantation. Arteriosclerosis is a risk factor for bleeding complications after LVAD implantation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
左心室辅助装置出血并发症的临床结果
出血并发症已成为植入式左心室辅助装置(LVAD)患者发病和死亡的主要原因。我们假设 LVAD 植入术后的血液动力学可能会影响 LVAD 植入术后出血并发症的发生。我们回顾性评估了大阪大学在 2017 年 7 月至 2023 年 7 月期间接受持续流 LVAD 植入术和 LVAD 植入术后血液动力学斜坡测试的 78 例患者。13名患者发生了出血并发症。1年、3年和5年的出血并发症治愈率分别为94%、85%和74%。胃肠道出血、鼻出血和腹腔出血分别发生在 6 名、3 名和 2 名患者身上。术前平均肱踝脉搏波速度(baPWV)与出血并发症呈正相关(1,276 ± 280 vs. 1,098 ± 190 cm/s p = 0.04)。在血液动力学斜坡试验中,有出血并发症患者的全身血管阻力(SVR)高于无出血并发症患者(SVR:1,359 ± 341 vs. 1,150 ± 217 dyne sec/cm5,P = 0.01)。术前高baPWV和血液动力学斜坡试验中高SVR与LVAD植入术后出血并发症显著相关。动脉硬化是 LVAD 植入术后出血并发症的一个危险因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
期刊最新文献
Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices. Heart Transplantation Outcomes in Patients With Hypertrophic Cardiomyopathy in the Era of Mechanical Circulatory Support. Predictive Accuracy of HeartMate 3 Risk Score After the Heart Transplant Allocation Change. Reply Letter to Editor to Daniel Schneditz. Impella as Bridge to Durable Left Ventricular Assist Device in Acute Myocardial Infarction Cardiogenic Shock Patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1