Patrick A Massey, Edwin Dudoussat, Carver Montgomery, Wayne Scalisi, Hayden McBride, Robert Rutz, Giovanni F Solitro
{"title":"Suture Tying Force for Cut-Out during Radial Meniscus Tear Repair: A Biomechanical Evaluation of Failure Loads during the Knot-Tying Process.","authors":"Patrick A Massey, Edwin Dudoussat, Carver Montgomery, Wayne Scalisi, Hayden McBride, Robert Rutz, Giovanni F Solitro","doi":"10.1177/19476035241284827","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of the study was to determine average tensile forces resulting in suture failure while tying a knot during repair of complete radial meniscus tears and to compare the failure tensile force based on meniscus tissue location: the peripheral (red-red) versus inner (white-white).</p><p><strong>Design: </strong>This study was designed as a cadaveric biomechanical study using 24 menisci harvested from fresh frozen cadaveric knees with midbody radial tears. Tears were repaired using 2-0 nonabsorbable suture in both the inner meniscus and the peripheral meniscus. A force gauge was used to measure the tension of a surgeon's knot until failure of either the suture or the meniscus tissue. Statistical analysis was performed comparing suture failure tensile forces between inner and peripheral sutures using 2-sample <i>t</i> test.</p><p><strong>Results: </strong>Suture repairs primarily failed due to meniscal tissue cut-out after suture tensioning (96%). There was no statistical difference in failure mode between medial and lateral meniscus for both the inner (100% cut-out) and the peripheral (92% cut-out; <i>P</i> = 0.703) sutures. The peripheral sutures failed as significantly higher loads (54 ± 26 N) than the inner sutures (36 ± 11 N, <i>P</i> = 0.006). The peripheral meniscus tissue tolerated significantly higher tension at failure (36 ± 7 N) than the inner meniscus (26 ± 7 N, <i>P</i> < 0.001).</p><p><strong>Conclusion: </strong>When tying parallel sutures to repair a radial meniscus tear, suture tensile forces above 30 N may tear through meniscus tissue. Surgeons should not use suture tying forces above 30 N when repairing radial meniscus tears with parallel sutures. The peripheral meniscus can withstand higher knot-tying forces than the inner meniscus, so surgeons should consider tying the peripheral suture before the inner suture.</p>","PeriodicalId":9626,"journal":{"name":"CARTILAGE","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556578/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CARTILAGE","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/19476035241284827","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The purpose of the study was to determine average tensile forces resulting in suture failure while tying a knot during repair of complete radial meniscus tears and to compare the failure tensile force based on meniscus tissue location: the peripheral (red-red) versus inner (white-white).
Design: This study was designed as a cadaveric biomechanical study using 24 menisci harvested from fresh frozen cadaveric knees with midbody radial tears. Tears were repaired using 2-0 nonabsorbable suture in both the inner meniscus and the peripheral meniscus. A force gauge was used to measure the tension of a surgeon's knot until failure of either the suture or the meniscus tissue. Statistical analysis was performed comparing suture failure tensile forces between inner and peripheral sutures using 2-sample t test.
Results: Suture repairs primarily failed due to meniscal tissue cut-out after suture tensioning (96%). There was no statistical difference in failure mode between medial and lateral meniscus for both the inner (100% cut-out) and the peripheral (92% cut-out; P = 0.703) sutures. The peripheral sutures failed as significantly higher loads (54 ± 26 N) than the inner sutures (36 ± 11 N, P = 0.006). The peripheral meniscus tissue tolerated significantly higher tension at failure (36 ± 7 N) than the inner meniscus (26 ± 7 N, P < 0.001).
Conclusion: When tying parallel sutures to repair a radial meniscus tear, suture tensile forces above 30 N may tear through meniscus tissue. Surgeons should not use suture tying forces above 30 N when repairing radial meniscus tears with parallel sutures. The peripheral meniscus can withstand higher knot-tying forces than the inner meniscus, so surgeons should consider tying the peripheral suture before the inner suture.
期刊介绍:
CARTILAGE publishes articles related to the musculoskeletal system with particular attention to cartilage repair, development, function, degeneration, transplantation, and rehabilitation. The journal is a forum for the exchange of ideas for the many types of researchers and clinicians involved in cartilage biology and repair. A primary objective of CARTILAGE is to foster the cross-fertilization of the findings between clinical and basic sciences throughout the various disciplines involved in cartilage repair.
The journal publishes full length original manuscripts on all types of cartilage including articular, nasal, auricular, tracheal/bronchial, and intervertebral disc fibrocartilage. Manuscripts on clinical and laboratory research are welcome. Review articles, editorials, and letters are also encouraged. The ICRS envisages CARTILAGE as a forum for the exchange of knowledge among clinicians, scientists, patients, and researchers.
The International Cartilage Repair Society (ICRS) is dedicated to promotion, encouragement, and distribution of fundamental and applied research of cartilage in order to permit a better knowledge of function and dysfunction of articular cartilage and its repair.