Using First Eye Early Vault to Determine ICL Size for the Second Eye: A Retrospective Analysis of Bilateral Phakic Intraocular Lens Implantation.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-09-25 DOI:10.1097/j.jcrs.0000000000001555
Honglei Li, Dongle Liu, Jinyan Zhang, Yunhai Dai, Xiaoming Wu
{"title":"Using First Eye Early Vault to Determine ICL Size for the Second Eye: A Retrospective Analysis of Bilateral Phakic Intraocular Lens Implantation.","authors":"Honglei Li, Dongle Liu, Jinyan Zhang, Yunhai Dai, Xiaoming Wu","doi":"10.1097/j.jcrs.0000000000001555","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the role of the first eye vault after the implantation of implantable collamer lens (ICL) V4c in selecting ICL size for the second eye and analyze the changing characteristics of the vault.</p><p><strong>Setting: </strong>Qingdao Eye Hospital of Shandong First Medical University.</p><p><strong>Design: </strong>Retrospective case series.</p><p><strong>Methods: </strong>In this retrospective study, 509 patients (1018 eyes) receiving bilateral ICL V4c implants were evaluated. Surgical management method was as follows: the vault was measured at 2 hours after the first eye surgery, and we selected ICL size for the second eye based on the vault of the first eye. The bilateral vault was measured and evaluated between different periods of follow-up.</p><p><strong>Results: </strong>The rate of ICL re-alignment or exchange due to abnormal vault was 1.47% (15/1018), with the second eye showing a significantly lower incidence (0.39%) compared to the first eye (2.55%)(P<0.01). Patients were categorized into four groups based on the vault value obtained at 2 hours postoperatively (baseline). There was significant difference in the value of vault decrease among the four groups at 1day, 1week, 1month, and 3months follow-up(all P<0.01). There was a significant positive correlation between the decrease in the vault and the baseline vault(all P < 0.01).</p><p><strong>Conclusion: </strong>Selecting the ICL size for the second eye based on the first eye's vault measurement 2 hours postoperatively can effectively minimize the need for further surgeries. Notably, eyes with a higher initial vault experienced a more pronounced decrease.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001555","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the role of the first eye vault after the implantation of implantable collamer lens (ICL) V4c in selecting ICL size for the second eye and analyze the changing characteristics of the vault.

Setting: Qingdao Eye Hospital of Shandong First Medical University.

Design: Retrospective case series.

Methods: In this retrospective study, 509 patients (1018 eyes) receiving bilateral ICL V4c implants were evaluated. Surgical management method was as follows: the vault was measured at 2 hours after the first eye surgery, and we selected ICL size for the second eye based on the vault of the first eye. The bilateral vault was measured and evaluated between different periods of follow-up.

Results: The rate of ICL re-alignment or exchange due to abnormal vault was 1.47% (15/1018), with the second eye showing a significantly lower incidence (0.39%) compared to the first eye (2.55%)(P<0.01). Patients were categorized into four groups based on the vault value obtained at 2 hours postoperatively (baseline). There was significant difference in the value of vault decrease among the four groups at 1day, 1week, 1month, and 3months follow-up(all P<0.01). There was a significant positive correlation between the decrease in the vault and the baseline vault(all P < 0.01).

Conclusion: Selecting the ICL size for the second eye based on the first eye's vault measurement 2 hours postoperatively can effectively minimize the need for further surgeries. Notably, eyes with a higher initial vault experienced a more pronounced decrease.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用第一眼早期穹隆确定第二眼的 ICL 大小:双侧角膜内人工晶体植入术的回顾性分析。
目的:评估植入可植入性人工晶体(ICL)V4c后第一眼穹隆在选择第二眼ICL大小中的作用,并分析穹隆的变化特征:山东第一医科大学附属青岛眼科医院:设计:回顾性病例系列:在这项回顾性研究中,对509例(1018眼)接受双侧ICL V4c植入术的患者进行了评估。手术管理方法如下:第一只眼手术后 2 小时测量穹隆,根据第一只眼的穹隆选择第二只眼的 ICL 大小。在不同的随访期间测量和评估双侧穹隆:结果:因穹隆异常而重新对准或更换 ICL 的比例为 1.47%(15/1018),与第一只眼(2.55%)相比,第二只眼的发生率(0.39%)明显较低(PC结论:为第一只眼选择 ICL 尺寸时,应考虑穹隆的大小:根据第一只眼睛术后 2 小时的穹隆测量结果来选择第二只眼睛的 ICL 大小,可以有效减少再次手术的需要。值得注意的是,初始穹隆较高的眼睛的穹隆度下降更为明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Ocular Shape of Cataract with Retinitis Pigmentosa: A Case-Control Study. Intraocular Lens Rotational Stability after Cataract Surgery with and without Primary Posterior Continuous Curvilinear Capsulorrhexis. Risk of Zonular Dialysis in Fellow-Eye Cataract Surgeries: A Multicenter Comparative Study. Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema. Analysis of the ESCRS calculator's prediction accuracy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1