Comparison of Elisar-Fast and Sita-Fast Strategy for Visual Field Assessment in Glaucoma.

IF 2 4区 医学 Q2 OPHTHALMOLOGY Journal of Glaucoma Pub Date : 2024-10-02 DOI:10.1097/IJG.0000000000002505
Priya Narang, Fareya Fatheema Rasheed, Amar Agarwal, Rhea Narang, Ashvin Agarwal
{"title":"Comparison of Elisar-Fast and Sita-Fast Strategy for Visual Field Assessment in Glaucoma.","authors":"Priya Narang, Fareya Fatheema Rasheed, Amar Agarwal, Rhea Narang, Ashvin Agarwal","doi":"10.1097/IJG.0000000000002505","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare two fast threshold strategies of visual field assessment: SITA-Fast (SF; Humphrey field analyser) and Elisar-Fast (EF; Advanced vision analyser) in patients with glaucoma.</p><p><strong>Methods: </strong>In this cross-sectional observational study, of total 192 subjects, 138 subjects [150 eyes, 80 glaucoma subjects (91 eyes) and 58 healthy controls (59 eyes)] were analysed and included. Each subject underwent 24-2 EF and SF in randomized order with a minimum time interval of 1 hour between tests.</p><p><strong>Main outcome measures: </strong>Mean test-time, pointwise and sectoral sensitivity, significance of values of mean sensitivity (MS) and global indices [mean deviation (MD) & pattern standard deviation (PSD)] and their correlation.</p><p><strong>Results: </strong>The mean test-time was 2.59±0.25 and 3.38±0.28 minutes (P = 0.001) with SF and EF respectively. Correlation coefficient for pointwise threshold values correlated strongly for both the devices (range from 0.70 to 0.92). The Intra class correlation (ICC) value of ≥ 0.8 was observed across all sectors indicating good reliability. Bland-Altman plot denoted 95% of data for MS values within limit of Agreement (LOA). The ICC values for overall MS, MD and PSD were 0.916, 0.913 and 0.872 respectively indicating good reliability. High degree of correlation was observed for MD (r = 0.912, P=0.00) and PSD values (r=0.732, P=0.00). Comparison of values indicated a difference of 1.09 dB for MD and 0.06 dB for PSD between both strategies.</p><p><strong>Conclusions: </strong>High degree of correlation existed between the global indices and pointwise threshold values. The study documents the ability of EF to successfully assess visual field in patients with glaucoma.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002505","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare two fast threshold strategies of visual field assessment: SITA-Fast (SF; Humphrey field analyser) and Elisar-Fast (EF; Advanced vision analyser) in patients with glaucoma.

Methods: In this cross-sectional observational study, of total 192 subjects, 138 subjects [150 eyes, 80 glaucoma subjects (91 eyes) and 58 healthy controls (59 eyes)] were analysed and included. Each subject underwent 24-2 EF and SF in randomized order with a minimum time interval of 1 hour between tests.

Main outcome measures: Mean test-time, pointwise and sectoral sensitivity, significance of values of mean sensitivity (MS) and global indices [mean deviation (MD) & pattern standard deviation (PSD)] and their correlation.

Results: The mean test-time was 2.59±0.25 and 3.38±0.28 minutes (P = 0.001) with SF and EF respectively. Correlation coefficient for pointwise threshold values correlated strongly for both the devices (range from 0.70 to 0.92). The Intra class correlation (ICC) value of ≥ 0.8 was observed across all sectors indicating good reliability. Bland-Altman plot denoted 95% of data for MS values within limit of Agreement (LOA). The ICC values for overall MS, MD and PSD were 0.916, 0.913 and 0.872 respectively indicating good reliability. High degree of correlation was observed for MD (r = 0.912, P=0.00) and PSD values (r=0.732, P=0.00). Comparison of values indicated a difference of 1.09 dB for MD and 0.06 dB for PSD between both strategies.

Conclusions: High degree of correlation existed between the global indices and pointwise threshold values. The study documents the ability of EF to successfully assess visual field in patients with glaucoma.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
青光眼视野评估中 Elisar-Fast 和 Sita-Fast 策略的比较。
目的:比较两种快速阈值视野评估策略:方法:在这项横断面观察研究中,共分析并纳入了 192 名受试者中的 138 名受试者[150 只眼睛,其中青光眼受试者 80 名(91 只眼睛),健康对照组 58 名(59 只眼睛)]。每位受试者按随机顺序进行 24-2 EF 和 SF 测试,两次测试之间至少间隔 1 小时:主要结果指标:平均测试时间、点和扇形灵敏度、平均灵敏度(MS)和总体指数[平均偏差(MD)和模式标准偏差(PSD)]值的显著性及其相关性:SF 和 EF 的平均测试时间分别为 2.59±0.25 分钟和 3.38±0.28 分钟(P = 0.001)。两种设备的点阈值相关系数都很高(范围在 0.70 至 0.92 之间)。所有区段的类内相关(ICC)值均≥ 0.8,表明可靠性良好。Bland-Altman图显示,95%的数据的MS值在协议限(LOA)内。总体 MS、MD 和 PSD 的 ICC 值分别为 0.916、0.913 和 0.872,表明可靠性良好。MD 值(r=0.912,P=0.00)和 PSD 值(r=0.732,P=0.00)具有高度相关性。数值比较表明,两种方法的 MD 值相差 1.09 dB,PSD 值相差 0.06 dB:结论:总体指数和点阈值之间存在高度相关性。该研究证明了 EF 能够成功评估青光眼患者的视野。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Glaucoma
Journal of Glaucoma 医学-眼科学
CiteScore
4.20
自引率
10.00%
发文量
330
审稿时长
4-8 weeks
期刊介绍: The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.
期刊最新文献
Association of Social Determinants of Health With the Likelihood of Treatment With Laser Trabeculoplasty in a US Database. Neighborhood Poverty and Clinic Attendance in the Michigan Screening and Intervention for Glaucoma and Eye Health Through Telemedicine Program. Wipe-Out Following Gonioscopy-Assisted Transluminal Trabeculotomy Combined With Phacoemulsification. Assessment of Missing Data on Glaucoma Severity Among Participants in the NIH All of Us Research Program of the United States. Compliance With International Council of Ophthalmology Guidelines for Glaucoma Eye Care in Pakistan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1