Yaqin Xia, Mingshu Yang, Tianyang Qian, Jiayu Zhou, Mei Bai, Siqi Luo, Chaogang Lu, Yinghao Zhu, Laishuan Wang, Zhongwei Qiao
{"title":"Prediction of feeding difficulties in neonates with hypoxic-ischemic encephalopathy using magnetic resonance imaging-derived radiomics features.","authors":"Yaqin Xia, Mingshu Yang, Tianyang Qian, Jiayu Zhou, Mei Bai, Siqi Luo, Chaogang Lu, Yinghao Zhu, Laishuan Wang, Zhongwei Qiao","doi":"10.1007/s00247-024-06065-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The mechanisms behind brain and spinal cord injuries in hypoxic-ischemic encephalopathy (HIE) and associated feeding difficulties are unclear, with previous magnetic resonance imaging (MRI) attempts yielding inconclusive results.</p><p><strong>Objective: </strong>We aim to evaluate an MRI radiomics model for predicting feeding difficulties in HIE infants. Additionally, we investigate changes in predictive capability after incorporating the duration of mechanical ventilation and the timing of MRI examination.</p><p><strong>Materials and methods: </strong>Retrospective study with 151 HIE infants (January 2013 to December 2021), randomly divided into training and validation sets. Radiomics features extracted from basal ganglia-thalamus and brainstem in T1-weighted and T2-weighted MRI. Established single-modality, single-site, and multimodality/multisite models. Receiver operating characteristic analysis and area under the curve evaluated models. Decision curve analysis assessed changes in predictive capability.</p><p><strong>Results: </strong>The combined radiomics model of the basal ganglia-thalamus and brainstem regions on the T2-weighted imaging demonstrated superior performance (area under the curve: 0.958 and 0.875 for training and validation, respectively). Combining scores with duration of mechanical ventilation and MRI examination time in a calibration plot model improved and stabilized performance, showing high fitting and clinical utility. Decision curve analysis favored the combined calibration plot model.</p><p><strong>Conclusion: </strong>The MRI-based radiomics model predicts feeding difficulties in HIE infants, with basal ganglia-thalamus and brainstem as relevant factors. The combined calibration plot model exhibits the highest clinical predictive efficacy.</p>","PeriodicalId":19755,"journal":{"name":"Pediatric Radiology","volume":" ","pages":"2036-2045"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00247-024-06065-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The mechanisms behind brain and spinal cord injuries in hypoxic-ischemic encephalopathy (HIE) and associated feeding difficulties are unclear, with previous magnetic resonance imaging (MRI) attempts yielding inconclusive results.
Objective: We aim to evaluate an MRI radiomics model for predicting feeding difficulties in HIE infants. Additionally, we investigate changes in predictive capability after incorporating the duration of mechanical ventilation and the timing of MRI examination.
Materials and methods: Retrospective study with 151 HIE infants (January 2013 to December 2021), randomly divided into training and validation sets. Radiomics features extracted from basal ganglia-thalamus and brainstem in T1-weighted and T2-weighted MRI. Established single-modality, single-site, and multimodality/multisite models. Receiver operating characteristic analysis and area under the curve evaluated models. Decision curve analysis assessed changes in predictive capability.
Results: The combined radiomics model of the basal ganglia-thalamus and brainstem regions on the T2-weighted imaging demonstrated superior performance (area under the curve: 0.958 and 0.875 for training and validation, respectively). Combining scores with duration of mechanical ventilation and MRI examination time in a calibration plot model improved and stabilized performance, showing high fitting and clinical utility. Decision curve analysis favored the combined calibration plot model.
Conclusion: The MRI-based radiomics model predicts feeding difficulties in HIE infants, with basal ganglia-thalamus and brainstem as relevant factors. The combined calibration plot model exhibits the highest clinical predictive efficacy.
期刊介绍:
Official Journal of the European Society of Pediatric Radiology, the Society for Pediatric Radiology and the Asian and Oceanic Society for Pediatric Radiology
Pediatric Radiology informs its readers of new findings and progress in all areas of pediatric imaging and in related fields. This is achieved by a blend of original papers, complemented by reviews that set out the present state of knowledge in a particular area of the specialty or summarize specific topics in which discussion has led to clear conclusions. Advances in technology, methodology, apparatus and auxiliary equipment are presented, and modifications of standard techniques are described.
Manuscripts submitted for publication must contain a statement to the effect that all human studies have been reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in an appropriate version of the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.