Diagnostic accuracy of percutaneous transthoracic needle biopsy among peripheral pulmonary lesions: a multicenter observational study.

IF 1.7 Q2 MEDICINE, GENERAL & INTERNAL Annals of Medicine and Surgery Pub Date : 2024-09-10 eCollection Date: 2024-10-01 DOI:10.1097/MS9.0000000000002539
Reza Basiri, Farzad Sharifnezhad, Amir H Jafarian, Sara Samadi, Amirreza Zarghi
{"title":"Diagnostic accuracy of percutaneous transthoracic needle biopsy among peripheral pulmonary lesions: a multicenter observational study.","authors":"Reza Basiri, Farzad Sharifnezhad, Amir H Jafarian, Sara Samadi, Amirreza Zarghi","doi":"10.1097/MS9.0000000000002539","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The diagnosis of peripheral pulmonary lesions (PPL) poses a significant challenge, prompting the widespread utilization of various modalities to ensure the precision in diagnosis. This study aims to assess the diagnostic accuracy of computed tomography-guided percutaneous transthoracic needle biopsy (CT-PTNB) in the context of pulmonary malignancy.</p><p><strong>Methods and materials: </strong>This multicenter retrospective observational study, included 1317 cases of CT-PTNB performed on adult patients with PPLs from January 2018 to December 2022 in Mashhad, Iran. The pathology results of CT-PTNB from 94 cases were compared to the definitive pathology results obtained through methods such as surgery to assess the sensitivity, specificity, and overall accuracy of CT-PTNB in diagnosing of pulmonary malignancy.</p><p><strong>Results: </strong>CT-PTNB exhibits an accuracy of 82.98%, with sensitivity and specificity rates of 75.41 and 91.43%, respectively. This study underscores the issue of false-negative results in CT-PTNB and underscores the importance of integrating clinical, radiological, and additional diagnostic modality to guide diagnostic decisions.</p><p><strong>Conclusion: </strong>In this large-scale multicenter study, the accuracy of CT-PTNB for diagnosis of pulmonary malignancy is acceptable but fairly low compared to previous studies.</p>","PeriodicalId":8025,"journal":{"name":"Annals of Medicine and Surgery","volume":"86 10","pages":"5762-5766"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11444528/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Medicine and Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/MS9.0000000000002539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The diagnosis of peripheral pulmonary lesions (PPL) poses a significant challenge, prompting the widespread utilization of various modalities to ensure the precision in diagnosis. This study aims to assess the diagnostic accuracy of computed tomography-guided percutaneous transthoracic needle biopsy (CT-PTNB) in the context of pulmonary malignancy.

Methods and materials: This multicenter retrospective observational study, included 1317 cases of CT-PTNB performed on adult patients with PPLs from January 2018 to December 2022 in Mashhad, Iran. The pathology results of CT-PTNB from 94 cases were compared to the definitive pathology results obtained through methods such as surgery to assess the sensitivity, specificity, and overall accuracy of CT-PTNB in diagnosing of pulmonary malignancy.

Results: CT-PTNB exhibits an accuracy of 82.98%, with sensitivity and specificity rates of 75.41 and 91.43%, respectively. This study underscores the issue of false-negative results in CT-PTNB and underscores the importance of integrating clinical, radiological, and additional diagnostic modality to guide diagnostic decisions.

Conclusion: In this large-scale multicenter study, the accuracy of CT-PTNB for diagnosis of pulmonary malignancy is acceptable but fairly low compared to previous studies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经皮穿刺活检对周围肺部病变的诊断准确性:一项多中心观察研究。
简介:肺外周病变(PPL)的诊断是一项重大挑战,促使人们广泛采用各种方法来确保诊断的准确性。本研究旨在评估计算机断层扫描引导下经皮经胸穿刺活检(CT-PTNB)对肺部恶性肿瘤的诊断准确性:这项多中心回顾性观察研究纳入了2018年1月至2022年12月期间在伊朗马什哈德为1317例PPLs成人患者实施的CT-PTNB。将94例CT-PTNB的病理结果与通过手术等方法获得的明确病理结果进行比较,以评估CT-PTNB诊断肺部恶性肿瘤的敏感性、特异性和总体准确性:CT-PTNB的准确率为82.98%,敏感性和特异性分别为75.41%和91.43%。这项研究强调了CT-PTNB假阴性结果的问题,并强调了综合临床、放射学和其他诊断方式来指导诊断决策的重要性:在这项大规模多中心研究中,CT-PTNB 诊断肺部恶性肿瘤的准确性是可以接受的,但与之前的研究相比,准确性相当低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Annals of Medicine and Surgery
Annals of Medicine and Surgery MEDICINE, GENERAL & INTERNAL-
自引率
5.90%
发文量
1665
期刊最新文献
Hereditary multiple exostoses with cervical spine involvement: a case report: Retraction. Acalvaria, rare congenital malformation in Palestine: case report and literature review: Retraction. Influence of clinical experience in detecting calcifications of the head and neck region on panoramic radiographs: an app-based evaluation. Apple Vision Pro as an augmentative tool in surgery: a double-edged scalpel. Management of recurrent end-stage achalasia with robotic-assisted esophagectomy: a case report and literature review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1