Simona Ferraro, Simona Lucchi, Chiara Montanari, Letizia Magnani, Martina Tosi, Davide Biganzoli, Andrea Lugotti, Laura Cappelletti, Alessia Poli, Elisa Pratiffi, Stephana Carelli, Laura Saielli, Luisella Alberti, Gianvincenzo Zuccotti, Marta Marsilio, Elvira Verduci, Cristina Cereda
{"title":"Vitamin B12 deficiency in newborns: impact on individual's health status and healthcare costs.","authors":"Simona Ferraro, Simona Lucchi, Chiara Montanari, Letizia Magnani, Martina Tosi, Davide Biganzoli, Andrea Lugotti, Laura Cappelletti, Alessia Poli, Elisa Pratiffi, Stephana Carelli, Laura Saielli, Luisella Alberti, Gianvincenzo Zuccotti, Marta Marsilio, Elvira Verduci, Cristina Cereda","doi":"10.1515/cclm-2024-0692","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The identification of vitamin B12 (B12) deficiency in the newborn may prevent neurological damage and a delay in the normal growth. In this study we characterized the incidence of B12 deficiency in newborns, the costs associated to the clinical diagnosis and management, and the relevance to optimize the use of cobalamin biomarkers during treatment follow-up.</p><p><strong>Methods: </strong>Starting from a continuous case series of 146,470 screened newborns (November, 1st 2021- December, 3rd 2023), the Regional Reference Laboratory for Neonatal Screening identified 87 newborns having altered levels of biomarkers of cobalamin metabolism measured by Newborn Screening. These subjects were confirmed with a nutritional B12 deficiency of maternal origin by performing the serum B12 measurements and plasma homocysteine (Hcy) both on the newborns and respective mothers. A cost analysis was performed to characterize the costs/year of identifying and managing B12 deficiency cases.</p><p><strong>Results: </strong>At baseline, median (interquartile range) serum B12 levels of 185.0 (142.3-246.0) ng/L and threefold increased plasma Hcy concentrations above the normal level confirmed a severe condition of deficiency in the newborns. After intramuscular B12 supplementation, serum B12 measured at the first follow up visit showed a fivefold increase, and the levels of Hcy returned to normal. From the healthcare perspective, the costs for diagnosing and managing all newborns with B12 deficiency is 188,480 €/year.</p><p><strong>Conclusions: </strong>Preventing B12 depletion in newborns lowers healthcare costs and likely improves their health outcomes. Further studies are however required to address the clinical pathway to identify, treat and monitor pregnant women with marginal and low B12 status, in order to achieve these goals.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0692","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The identification of vitamin B12 (B12) deficiency in the newborn may prevent neurological damage and a delay in the normal growth. In this study we characterized the incidence of B12 deficiency in newborns, the costs associated to the clinical diagnosis and management, and the relevance to optimize the use of cobalamin biomarkers during treatment follow-up.
Methods: Starting from a continuous case series of 146,470 screened newborns (November, 1st 2021- December, 3rd 2023), the Regional Reference Laboratory for Neonatal Screening identified 87 newborns having altered levels of biomarkers of cobalamin metabolism measured by Newborn Screening. These subjects were confirmed with a nutritional B12 deficiency of maternal origin by performing the serum B12 measurements and plasma homocysteine (Hcy) both on the newborns and respective mothers. A cost analysis was performed to characterize the costs/year of identifying and managing B12 deficiency cases.
Results: At baseline, median (interquartile range) serum B12 levels of 185.0 (142.3-246.0) ng/L and threefold increased plasma Hcy concentrations above the normal level confirmed a severe condition of deficiency in the newborns. After intramuscular B12 supplementation, serum B12 measured at the first follow up visit showed a fivefold increase, and the levels of Hcy returned to normal. From the healthcare perspective, the costs for diagnosing and managing all newborns with B12 deficiency is 188,480 €/year.
Conclusions: Preventing B12 depletion in newborns lowers healthcare costs and likely improves their health outcomes. Further studies are however required to address the clinical pathway to identify, treat and monitor pregnant women with marginal and low B12 status, in order to achieve these goals.
期刊介绍:
Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically.
CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France).
Topics:
- clinical biochemistry
- clinical genomics and molecular biology
- clinical haematology and coagulation
- clinical immunology and autoimmunity
- clinical microbiology
- drug monitoring and analysis
- evaluation of diagnostic biomarkers
- disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes)
- new reagents, instrumentation and technologies
- new methodologies
- reference materials and methods
- reference values and decision limits
- quality and safety in laboratory medicine
- translational laboratory medicine
- clinical metrology
Follow @cclm_degruyter on Twitter!