{"title":"The impacts of roller compaction on the quality attributes of simultaneously compressed micro and minitablets","authors":"","doi":"10.1016/j.ijpharm.2024.124785","DOIUrl":null,"url":null,"abstract":"<div><div>The challenges of developing good quality low dose minitablets was assessed by systematically studying the effects of ibuprofen (IBU, a model compound) particle sizes (6–58 µm D<sub>50</sub>) and concentrations (0.1–3 %w/w), roller compaction forces (3–7 kN/cm), and the minitablet sizes (1.2, 1.5 and 2 mm diameter). A novel compression approach, where all three minitablet sizes were simultaneously produced in a single compression run was used. Roller compacted ribbons, granules, minitablets were characterized for physico-mechanical properties and minitablets were also characterized for stratified content uniformity and weight uniformity. The results showed that roll force was the more dominant factor to ribbon solid fraction or tensile strength and granule size enlargement. Minitablets obtained from the granules had good weight uniformity; all but one batch met the &lt;Ph. Eur. 2.9.5 &gt; criteria. The precise control of tooling lengths across the various sizes was found profoundly important for achieving expected weights, solid fraction, and tensile strength of the simultaneously produced minitablets. The roller compaction process considerably improved the CU variability of the minitablets as compared to the direct compression process. Smaller particle size and higher concentration of IBU, increased roller compaction force, and larger minitablet size improved the potency and content uniformity; however, only the minitablet size was a statistically significant factor in this study. As a product strategic design criterion, a threshold of 25 minitablets in a dosage unit would ensure robust downstream filling and weight verification operations as well as dose accuracy and uniformity (would pass &lt;USP 905&gt; stage 1 criteria). This study results demonstrated feasibility of the novel simultaneous compression approach and the roller compaction process in developing good quality minitablets.</div></div>","PeriodicalId":14187,"journal":{"name":"International Journal of Pharmaceutics","volume":null,"pages":null},"PeriodicalIF":5.3000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378517324010196","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

The challenges of developing good quality low dose minitablets was assessed by systematically studying the effects of ibuprofen (IBU, a model compound) particle sizes (6–58 µm D50) and concentrations (0.1–3 %w/w), roller compaction forces (3–7 kN/cm), and the minitablet sizes (1.2, 1.5 and 2 mm diameter). A novel compression approach, where all three minitablet sizes were simultaneously produced in a single compression run was used. Roller compacted ribbons, granules, minitablets were characterized for physico-mechanical properties and minitablets were also characterized for stratified content uniformity and weight uniformity. The results showed that roll force was the more dominant factor to ribbon solid fraction or tensile strength and granule size enlargement. Minitablets obtained from the granules had good weight uniformity; all but one batch met the <Ph. Eur. 2.9.5 > criteria. The precise control of tooling lengths across the various sizes was found profoundly important for achieving expected weights, solid fraction, and tensile strength of the simultaneously produced minitablets. The roller compaction process considerably improved the CU variability of the minitablets as compared to the direct compression process. Smaller particle size and higher concentration of IBU, increased roller compaction force, and larger minitablet size improved the potency and content uniformity; however, only the minitablet size was a statistically significant factor in this study. As a product strategic design criterion, a threshold of 25 minitablets in a dosage unit would ensure robust downstream filling and weight verification operations as well as dose accuracy and uniformity (would pass <USP 905> stage 1 criteria). This study results demonstrated feasibility of the novel simultaneous compression approach and the roller compaction process in developing good quality minitablets.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
轧辊压实对同时压缩的微型和小型药包质量属性的影响。
通过系统研究布洛芬(IBU,一种示范化合物)的粒度(6-58 µm D50)和浓度(0.1-3 %w/w)、辊压力(3-7 kN/cm)以及迷你片尺寸的影响,评估了开发优质低剂量迷你片所面临的挑战。采用了一种新颖的压制方法,即在一次压制过程中同时生产三种尺寸(1.2、1.5 和 2 毫米)的小itablet。对轧辊压制的带状、颗粒状和小乳剂进行了物理机械性能表征,还对小乳剂的分层含量均匀性和重量均匀性进行了表征。结果表明,碾压力是影响带状固体成分或抗拉强度以及颗粒尺寸增大的主要因素。从颗粒中获得的迷你乳清片具有良好的重量均匀性;除一批外,其他所有批次均符合标准。精确控制各种规格的工具长度,对于同时生产的迷你片达到预期重量、固体分数和拉伸强度非常重要。与直接压制工艺相比,辊筒压制工艺大大改善了迷你板坯的 CU 变异性。更小的颗粒尺寸和更高的 IBU 浓度、更大的轧辊压实力和更大的迷你片尺寸都提高了药效和含量的均匀性;然而,在本研究中,只有迷你片尺寸是一个具有统计学意义的因素。作为产品战略设计标准,一个配料单位中 25 个小药包的阈值可确保下游灌装和重量验证操作的稳健性以及剂量的准确性和均匀性(通过第 1 阶段标准)。研究结果表明,新颖的同步压缩方法和辊压工艺在开发优质迷你片方面具有可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
10.70
自引率
8.60%
发文量
951
审稿时长
72 days
期刊介绍: The International Journal of Pharmaceutics is the third most cited journal in the "Pharmacy & Pharmacology" category out of 366 journals, being the true home for pharmaceutical scientists concerned with the physical, chemical and biological properties of devices and delivery systems for drugs, vaccines and biologicals, including their design, manufacture and evaluation. This includes evaluation of the properties of drugs, excipients such as surfactants and polymers and novel materials. The journal has special sections on pharmaceutical nanotechnology and personalized medicines, and publishes research papers, reviews, commentaries and letters to the editor as well as special issues.
期刊最新文献
Chitosan gel loaded with carbon dots and mesoporous hydroxyapatite nanoparticles as a topical formulation for skin regeneration: An animal study Quality by design-based optimization of teriflunomide and quercetin combinational topical transferosomes for the treatment of rheumatoid arthritis Nasal administration of Xingnaojing biomimetic nanoparticles for the treatment of ischemic stroke Silk fibroin/chitosan thiourea hydrogel scaffold with vancomycin and quercetin-loaded PLGA nanoparticles for treating chronic MRSA osteomyelitis in rats Erlotinib and curcumin-loaded nanoparticles embedded in thermosensitive chitosan hydrogels for enhanced treatment of head and neck cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1