Validation of steps countering recorded with a smartwatch.

IF 1.2 4区 医学 Q3 SPORT SCIENCES Journal of Sports Medicine and Physical Fitness Pub Date : 2024-10-03 DOI:10.23736/S0022-4707.24.15888-4
David Cyrol, Sven Bechtold, Hendrik MATTHIEßEN, Stefan Sammito
{"title":"Validation of steps countering recorded with a smartwatch.","authors":"David Cyrol, Sven Bechtold, Hendrik MATTHIEßEN, Stefan Sammito","doi":"10.23736/S0022-4707.24.15888-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Activity trackers are becoming increasingly popular in everyday life, sport and research. Accurate measurement of step counts is essential for understanding an individual's daily activity levels and promoting healthier lifestyles. As the sensor technology has become very sophisticated, such a device can be worn on the body for several hours or days without restricting the subject's daily activities. The aim of this study was to evaluate the accuracy of a commercially available wrist-worn pedometer in accurately recording step counts.</p><p><strong>Methods: </strong>A total of twenty-one subjects participated in this comparative study by running at various speeds in a laboratory setting while wearing a Garmin Forerunner 245 Music watch (Garmin Ltd, Schaffhausen, Switzerland) on each wrist. Simultaneously, their steps were recorded by a camera system. The step counts recorded by the pedometer were compared with the counts obtained by the camera system. Descriptive statistical analyses such as Pearson correlation and Bland-Altman plots were used to assess the accuracy and reliability of the pedometer.</p><p><strong>Results: </strong>For most settings the results on the treadmills showed a high correlation between the pedometer and the camera system. On the step machine the results showed a low correlation between the pedometer and the camera system, the pedometer showed a systematic bias by consistently overestimating the number of steps. Bland-Altman plots showed that the results were within the limits of agreement.</p><p><strong>Conclusions: </strong>Although pedometers provide a convenient tool for monitoring step count, this study highlights some limitations and potential inaccuracies of a commercially available pedometer. Our study indicates that the Garmin watch is sufficiently accurate to be used as a measurement tool in a treadmill running environment.</p>","PeriodicalId":17013,"journal":{"name":"Journal of Sports Medicine and Physical Fitness","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sports Medicine and Physical Fitness","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0022-4707.24.15888-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Activity trackers are becoming increasingly popular in everyday life, sport and research. Accurate measurement of step counts is essential for understanding an individual's daily activity levels and promoting healthier lifestyles. As the sensor technology has become very sophisticated, such a device can be worn on the body for several hours or days without restricting the subject's daily activities. The aim of this study was to evaluate the accuracy of a commercially available wrist-worn pedometer in accurately recording step counts.

Methods: A total of twenty-one subjects participated in this comparative study by running at various speeds in a laboratory setting while wearing a Garmin Forerunner 245 Music watch (Garmin Ltd, Schaffhausen, Switzerland) on each wrist. Simultaneously, their steps were recorded by a camera system. The step counts recorded by the pedometer were compared with the counts obtained by the camera system. Descriptive statistical analyses such as Pearson correlation and Bland-Altman plots were used to assess the accuracy and reliability of the pedometer.

Results: For most settings the results on the treadmills showed a high correlation between the pedometer and the camera system. On the step machine the results showed a low correlation between the pedometer and the camera system, the pedometer showed a systematic bias by consistently overestimating the number of steps. Bland-Altman plots showed that the results were within the limits of agreement.

Conclusions: Although pedometers provide a convenient tool for monitoring step count, this study highlights some limitations and potential inaccuracies of a commercially available pedometer. Our study indicates that the Garmin watch is sufficiently accurate to be used as a measurement tool in a treadmill running environment.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
验证智能手表记录的步数。
背景:活动追踪器在日常生活、运动和研究中越来越受欢迎。准确测量步数对于了解个人的日常活动水平和促进更健康的生活方式至关重要。由于传感器技术已经非常成熟,这种设备可以佩戴在身上数小时或数天,而不会限制受试者的日常活动。本研究旨在评估市售腕式计步器在准确记录步数方面的准确性:共有 21 名受试者参加了这项比较研究,他们在实验室环境中以不同速度跑步,同时在每个手腕上佩戴 Garmin Forerunner 245 音乐手表(Garmin 有限公司,瑞士沙夫豪森)。同时,他们的步数被摄像系统记录下来。计步器记录的步数与摄像系统获得的步数进行比较。使用皮尔逊相关性和布兰德-阿尔特曼图等描述性统计分析来评估计步器的准确性和可靠性:在大多数设置中,跑步机上的结果显示计步器和摄像系统之间有很高的相关性。在踏步机上,计步器和摄像系统之间的相关性较低,计步器显示出系统性偏差,一直高估步数。Bland-Altman图显示结果在一致范围内:尽管计步器为监测步数提供了方便的工具,但本研究强调了市售计步器的一些局限性和潜在误差。我们的研究表明,Garmin 手表的准确性足以在跑步机跑步环境中用作测量工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
5.90%
发文量
393
审稿时长
6-12 weeks
期刊介绍: The Journal of Sports Medicine and Physical Fitness publishes scientific papers relating to the area of the applied physiology, preventive medicine, sports medicine and traumatology, sports psychology. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, special articles, letters to the Editor and guidelines.
期刊最新文献
Factor analysis on the performance of elite male fencing athletes. Stepping towards relief: a scoping review on the impact of unstable footwear in chronic low back pain management. Peak torque and eccentric rate of torque development of the hamstrings might not be reflected by contractile properties measured by tensiomyography. The effect of baseball grips on the hardness of the flexor digitorum superficialis. Affective, perceptual and physiologic responses to isokinetic contractions under blood flow restriction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1